Download presentation
Presentation is loading. Please wait.
Published byBrennen Rumley Modified over 10 years ago
1
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface VIA ROMA, 20 - I-36051 CREAZZO (VI) ITALY PHONE ++39-0444-396111 - FAX ++39-0444- 390908 www.meccalte.com E-mail: mecc-alte-spa@meccalte.it www.meccalte.com E-mail: mecc-alte-spa@meccalte.it
2
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Regulator Board
3
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Regulator Board Regulator Firmware
4
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Regulator Board Functional Parameters Regulator Firmware
5
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Regulator Board Functional Parameters Programming and monitoring Device Regulator Firmware
6
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Regulator Board Functional Parameters Programming and monitoring Device Regulator Firmware Connection cable
7
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Regulator Board Functional Parameters Mecc Terminal Software (Customer Interface) Programming and monitoring Device Regulator Firmware Connection cable
8
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Regulator Board
9
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac
10
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz
11
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac
12
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition
13
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: ±0,25%
14
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: 0,25% Voltage recovery within ± 3% of the original value tr< 300msec
15
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: 0,25% Voltage recovery within 3% of the original value tr< 300msec Single or 3or loaded phase sensing
16
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: 0,25% Voltage recovery within 3% of the original value tr< 300msec Single or 3or loaded phase sensing Regulation on the minimum or maximum of 3-phase voltage or the average of the 3 phases
17
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: 0,25% Voltage recovery within 3% of the original value tr< 300msec Single or 3or loaded phase sensing Regulation on the minimum or maximum of 3-phase voltage or the average of the 3 phases Default settings: VOLT, STAB, AMP, HZ by trimmer, 50/60Hz by jumper. All the values are adjustable via software
18
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: 0,25% Voltage recovery within 3% of the original value tr< 300msec Single or 3or loaded phase sensing Regulation on the minimum or maximum of 3-phase voltage or the average of the 3 phases Default settings: VOLT, STAB, AMP, HZ by trimmer, 50/60Hz by jumper. All the values are adjustable via software Analogical remote control of the output voltage by a potentiometer or dc voltage (-5Vdc ÷ +5Vdc)
19
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: 0,25% Voltage recovery within 3% of the original value tr< 300msec Single or 3or loaded phase sensing Regulation on the minimum or maximum of 3-phase voltage or the average of the 3 phases Default settings: VOLT, STAB, AMP, HZ by trimmer, 50/60Hz by jumper. All the values are adjustable via software Analogical remote control of the output voltage by a potentiometer or dc voltage (-5Vdc ÷ +5Vdc) Visualization by 7-segment display
20
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: 0,25% Voltage recovery within 3% of the original value tr< 300msec Single or 3or loaded phase sensing Regulation on the minimum or maximum of 3-phase voltage or the average of the 3 phases Default settings: VOLT, STAB, AMP, HZ by trimmer, 50/60Hz by jumper. All the values are adjustable via software Analogical remote control of the output voltage by a potentiometer or dc voltage (-5Vdc ÷ +5Vdc) Visualization by 7-segment display RS232 and RS485
21
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: 0,25% Voltage recovery within 3% of the original value tr< 300msec Single or 3or loaded phase sensing Regulation on the minimum or maximum of 3-phase voltage or the average of the 3 phases Default settings: VOLT, STAB, AMP, HZ by trimmer, 50/60Hz by jumper. All the values are adjustable via software Analogical remote control of the output voltage by a potentiometer or dc voltage (-5Vdc ÷ +5Vdc) Visualization by 7-segment display RS232 and RS485 Ambient temperature: -25°C +70°C
22
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface FEATURES Voltage supply: 30Vac÷280Vac Frequency range: 12Hz ÷ 72Hz Sensing 0÷900 Vac Maximum current: 5Adc; up to 15Adc during a transient condition Voltage regulation accuracy: 0,25% Voltage recovery within 3% of the original value tr< 300msec Single or 3or loaded phase sensing Regulation on the minimum or maximum of 3-phase voltage or the average of the 3 phases Default settings: VOLT, STAB, AMP, HZ by trimmer, 50/60Hz by jumper. All the values are adjustable via software Analogical remote control of the output voltage by a potentiometer or dc voltage (-5Vdc ÷ +5Vdc) Visualization by 7-segment display RS232 and RS485 Ambient temperature: -25°C +70°C Embedded PD, VAR & PFR
23
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Singlee phase sensing - Parallel with Mains Supply NOTE: Parallel connection with Mains Supply needs T.A.
24
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Single phase sensing - Parallel with Mains Supply Exciter and Feeding connection
25
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Single phase sensing - Parallel with Mains Supply Line and Phase sensing connection
26
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Single phase sensing - Parallel with Mains Supply T.A. Connection on J2 connector
27
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Single phase sensing - Parallel with Mains Supply External Voltage Input or remote Potentiometer Input (J3 connector)
28
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Single phase sensing - Parallel with Mains Supply Temperature Interface (External Board on J7 connector)
29
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Single phase sensing - Parallel with Mains Supply Jumpers RBD Set and 50/60Hz or Switches Vmatch and PFR_on (J4 connector)
30
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Single phase sensing - Parallel with Mains Supply Auxiliary Contact of Parallel Switch Enabling Embedded PD (J4 connector)
31
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Single phase sensing - Parallel with Mains Supply Operating of Parallel Switch Enable (J5 connector)
32
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection: Single phase sensing - Parallel with Mains Supply A.P.O. Contact and Active Power Out signal on J5 connector
33
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Exemple of connection diagram: Trhree phase sensing - complete connection
34
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters
35
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters
36
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters Underspeed Kneepoint Overspeed Threshold
37
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters
38
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters + - Iexc RC Iexc threshold AMP 32767 Vnom + - Voltage Reference Reg. Threshold value is adjustable by AMP trimmer or via software at address 23. Estimated temperature (Vc%) is available at address 89. The excitation current is reduced by the regulator when the temperature (exponential line) reaches the threshold (horizontal line). R and C values are fixed.
39
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters Parallel Operations Parallel Device
40
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters Parallel Operations Parallel DeviceParallel Device PAR_SW_EN = (Word alarms) AND (Mask alarms)PSwEn Mask: PAR_SW_EN = (Word alarms) AND (Mask alarms) Add. 56 (57) Add. 27 (28)
41
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters Parallel Operations Parallel Device PSwEn Mask Reactive references
42
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters Parallel Operations Parallel Device PSwEn Mask Reactive references Dinamic of Power regulation
43
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters Parallel Operations Parallel Device PSwEn Mask Reactive references Dinamic of Power regulation Inputs configuration
44
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Functional Parameters Parallel Operations: Inputs configuration
45
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Regulator Board Programming and monitoring Device Connection cable Programming the regulator
46
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Mecc Terminal Software (Customer Interface) Programming and monitoring Device
47
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Com Port - Settings menu Programming and monitoring Device
48
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Configuration menu Programming and monitoring Device
49
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Configuration menu Programming and monitoring Device
50
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Alarms description
51
DIRCI 04Digital Regulator with Customer Interface DIRCI 04 Digital Regulator with Customer Interface Refer to Dirci04 Instruction Manual for a correct use and updated technical information. This information has to be only considered as a reference of DIRCI04 regulator. It is not exhaustive and could be not updated according to the last version available.
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.