1
Quick Reference Troubleshooting
Common Service Components PFE29 BM Freezer
2
New GE French Door refrigerator
Door Hinge Guide Leveling Guide
3
Door Hinge Alignment for re-install
Purple mark indicator orientated towards alignment arrow to reinstall door at 90° to case front Hinge cam parallel to alignment arrow is correct to reinstall door at 90° to case front Purple dot facing arrow correct NOTE: An improper door installation could result in the door “popping” open instead of “pulling” closed Parallel to arrow correct Hinge cam perpendicular to alignment arrow is incorrect Perpendicular to arrow incorrect
4
Freezer Defrost Heater
~ Service mode: (Water-Crushed-Cubed) ~ (In Control Display) ~ J1 Pin 3 orange- ( neutral ) ~ J1 Pin 4 FZ defrost heater ~ 120 VAC ~ 33 Ohms 3 4 J1-3
5
Fresh Food Defrost Heater
2 3 ~ Service mode: (Water-Crushed-Cubed) ~ (In Control Display) ~ J1 Pin 3 orange- ( neutral ) ~ J2 Pin 2 FF defrost heater ~ 120 VAC ~ 85 Ohms J1-3
6
Fresh Food Fan ~ Service mode: (Water-Crushed-Cubed)
RPM PWM Supply voltage DC Common +12 VDC ~ Service mode: (Water-Crushed-Cubed) ~ (Displayed) ~ J6 Pin VDC ~ J6 Pin DC Common (*Use for all tests) ~ J6 Pin to 12 VDC (3 speed) ~ J6 Pin < 112 Hz ( Red * dot indicates a wire in terminal)
7
Freezer Fan ~ Service mode: (Water-Crushed-Cubed) ~ 00 48 (Displayed)
+12 VDC DC Common PWM Supply voltage RPM ~ Service mode: (Water-Crushed-Cubed) ~ (Displayed) ~ J8 Pin VDC ~ J8 Pin DC Common (*Use for all tests) ~ J8 Pin to 12 VDC (3 speed) ~ J8 Pin < 112 Hz 8 -> 1
8
Ice Box Fan ~ Service mode: (Water-Crushed-Cubed) ~ 00 47 (Displayed)
+12 VDC DC Common PWM Supply voltage RPM ~ Service mode: (Water-Crushed-Cubed) ~ (Displayed) ~ J8 Pin VDC ~ J8 Pin DC Common (*Use for all tests) ~ J8 Pin to 12 VDC (3 speed) ~ J8 Pin < 112 Hz 8 -> 1
9
Thermistors Service mode: 00 24 FF Cabinet 00 26 FF Evap.
FZ Cabinet FZ Evap. (Displays actual temps.) J11 J10 (Red * dot indicates a wire in terminal)
10
Icemaker’s Door Board Service mode: ( Water – Crushed – Cubed)
DB I/M Rake Motor Turned On / 120VAC Aqua & Orange DB I/M Mold Heater Turned On / 120VAC Purple & Orange Door Board Mold Heater Mold Heater Rake Motor Rake Motor DC AC