1 removal of approximal enamel
KaVo O-Drive KaVo O-drive OD30 removal of approximal enamel © KaVo Dental GmbH

2 KaVo O-drive OD30 KaVo O-drive Set consisting of:
KaVo O-drive OD30 instrument OS-discs – oscillating segment discs © KaVo Dental GmbH

3 KaVo O-drive OD30 Technical data KaVo O-drive OD 30:
reduction: 7,4 : 1 movement: oscillating movement with 30° Bur shaft: Multiple-Spline Shaft best for oscillating movement small tolerances – perfect control best fixing in the instrument © KaVo Dental GmbH

4 KaVo O-drive OD30 Technical date segment discs:
(Komet, Brasseler: Patent DE ) OS = oscillating stripping F = middle coating D54 M = fine coating D 25 000 = special shaft 140 = radius of discs (here 14 mm) © KaVo Dental GmbH

5 KaVo O-drive OD30 The use of KaVo OD 30 :
For removing of aproximal enamel ASR To achieve free space for a correction of wrong or/and bad placed teeth To achieve free space for insertion of implants To avoid extensions on younger patients,if there is not enough space for the permanent teeth © KaVo Dental GmbH

6 KaVo O-drive OD30 Clinical case – Prof. Joost-Brinkmann KaVo O-Drive
© KaVo Dental GmbH

7 KaVo O-drive OD30 Clinical case – Prof. Joost-Brinkmann KaVo O-Drive
© KaVo Dental GmbH

8 KaVo O-drive OD30 Clinical case – Prof. Joost-Brinkmann KaVo O-Drive
© KaVo Dental GmbH

9 KaVo O-drive OD30 Clinical case – Prof. Joost-Brinkmann KaVo O-Drive
© KaVo Dental GmbH

10 KaVo O-drive OD30 Clinical case – Prof. Joost-Brinkmann KaVo O-Drive
© KaVo Dental GmbH

11 KaVo O-drive OD30 Advantages:
Faster and more precise as stripping with manual system No harm of soft material through oscillating movement © KaVo Dental GmbH

12 KaVo O-drive OD30 Movement system O-drive system
Radial movement through the complete working area Reduction of enamel in one working step No „stairs“ No „canting“ Fast working © KaVo Dental GmbH

13 KaVo O-drive OD30 Use if the segment discs
Working data: to movements (osc/minute) Segment discs is placed from occlusal and guided in one movement through the contact point . Indication only to be done with efficient cooling (min. 50 ml/min.) Afterwards a polishing is needed © KaVo Dental GmbH

14 KaVo O-drive OD30 competitors: Fa. Intensiv with ORTHO-strips-system
Surface can not be done in one working step Bad access in the molar area © KaVo Dental GmbH