Selection of Power Filters for Switched Mode Power Supplies
Konstantin Kostov Jukka-Pekka Sjöroos J. Kyyrä and T. Suntio Power Electronics Laboratory Helsinki University of Technology
2
Selection of Power Filters for Switched Mode Power Supplies
Content Insertion Loss EMI measurements EMI measured at the line & neutral CM and DM noise measurements Comparison between different IL data Conclusions Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
3
Selection of Power Filters for Switched Mode Power Supplies
Insertion Loss (IL) Calculations IL measuring set up IL data from power filter manufacturers: Usually 50 Ω / 50 Ω source and load impedance Also based on CISPR 17 the so-called ”approximate worst case” IL measurements: 0.1 Ω / 100 Ω 100 Ω / 0.1 Ω The closed loop system may even become unstable when the design infinite-precission controller is implemented with a fixed-point digital processor due to the finite precission of the parameter representation resulting from the FWL Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
4
EMI Filter CY = 4.7 nF LCM = 4.2 mH CX1 = CX2 = 100 nF Lleak = 37 H
CM & DM equivalent circuits CY = 4.7 nF LCM = 4.2 mH CX1 = CX2 = 100 nF Lleak = 37 H Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
5
Measured and Calculated CM IL
Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
6
Measured and Calculated DM IL
Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
7
Conducted Emissions Measurements
Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
8
Buck Converter Used in Measurements
fs = 250 kHz Uin = 35 V CE = 220 F Uo = 12 V L = 190 H Io = 1 A C = 100 F Iin = 0.38 A Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
9
EMI from a Buck Converter (Line)
Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
10
EMI from a Buck Converter (Neutral)
Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
11
Selection of Power Filters for Switched Mode Power Supplies
Measuring CM EMI Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
12
Selection of Power Filters for Switched Mode Power Supplies
Measured CM EMI CM and DM Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
13
Selection of Power Filters for Switched Mode Power Supplies
Measuring DM EMI Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
14
Selection of Power Filters for Switched Mode Power Supplies
Measured DM EMI CM and DM Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
15
CM Noise Attenuation Measured, Calculated and Actual
Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
16
DM Noise Attenuation Measured, Calculated and Actual
Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
17
Selection of Power Filters for Switched Mode Power Supplies
Conclusions The attenuation of a passive EMI filter operating with a SMPS can be about: The CM IL data for 0.1 / 100 source / load impedance. The DM IL data for 100 / 0.1 source / load impedance. The actual IL can be a lot lower than the standard 50 / 50 IL data. Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
18
Measured CM and DM EMI (with Tektronix A6312 Current Probe)
Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
19
Selection of Power Filters for Switched Mode Power Supplies
DM Noise Attenuation Y3 Z2 Y1 Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
20
Selection of Power Filters for Switched Mode Power Supplies
CM Noise Attenuation Z2 Y1 Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
21
Components’ Impedances
Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018
22
EMI Filter Topology and Equivalent Circuits
Usually π-filters are used DM equivalent circuit CM equivalent circuit Selection of Power Filters for Switched Mode Power Supplies 22 September, 2018