Download presentation
Presentation is loading. Please wait.
1
Chapters 6 & 7 (Selected Topics)
Actuators Workhorses of the System
2
Objectives Describe the construction and operation of basic hydraulic cylinders, limited-rotation actuators, and motors. Compare the design and operation of various types of hydraulic cylinders. Select appropriate cylinder design options available for mounting hydraulic cylinders and reducing hydraulic shock. Compare the design and operation of various types of hydraulic motors.
3
Objectives Contrast the operation of fixed- and variable-speed hydraulic motors. Describe the construction and operation of a basic hydrostatic transmission. Size hydraulic cylinders and motors to correctly meet system force and speed requirements. Interpret manufacturer specifications for hydraulic cylinders.
4
Hydraulic Cylinders Actuators are the components used in a hydraulic system to provide power to a required work location Cylinders are the hydraulic system components that convert fluid pressure and flow into linear mechanical force and movement
5
Hydraulic Cylinders A basic cylinder consists of: Piston Piston rod
Barrel
6
Hydraulic Cylinders Parts of a typical cylinder
7
Hydraulic Cylinders The piston forms sealed, variable-volume chambers in the cylinder System fluid forced into the chambers drives the piston and rod assembly Linear movement is produced
8
Hydraulic Cylinders Seals prevent leakage between:
Piston and cylinder barrel Piston rod and head Barrel and its endpieces Wiper seal, or scraper, prevents dirt and water from entering the cylinder during rod retraction
9
Hydraulic Cylinders Various seals are used in a cylinder
10
Hydraulic Cylinders Rod wipers prevent contamination from entering on rod retraction IMI Norgren, Inc.
11
Hydraulic Cylinders Cylinders are typically classified by operating principle or by construction type Single-acting or double-acting Tie rod, mill, threaded end, or one piece
12
Hydraulic Cylinders Single- and double-acting cylinders Single-acting
13
Hydraulic Cylinders Single-acting cylinders exert force either on extension or retraction They require an outside force to complete the second motion
14
Hydraulic Cylinders Double-acting cylinders generate force during both extension and retraction Directional control valve alternately directs fluid to opposite sides of the piston Force output varies between extension and retraction
15
Hydraulic Cylinders Effective piston area is reduced on retraction due to the rod cross section
16
Hydraulic Cylinders Volume is reduced on retraction
17
Hydraulic Cylinders One-piece cylinder has the cylinder barrel welded to the ends Produces a compact actuator Cost effective to manufacture Cannot be serviced (throwaway)
18
Hydraulic Cylinders Hydraulic ram is commonly used in hand-operated jacks Rod is basically the same diameter as the inside of the cylinder barrel Large-diameter rod is more rigid under load, but cylinder can generate force in only one direction
19
Hydraulic Cylinders The force generated by a cylinder is calculated by multiplying the effective area of the piston by the system pressure
20
Hydraulic Cylinders Effective cylinder piston area
21
Hydraulic Cylinders Force generated during the extension of a double-acting cylinder with a single-ended rod is calculated as: extension force = system pressure piston area Force generated during the retraction of a double-acting cylinder with a single-ended rod is calculated as: retraction force = system pressure (piston area – rod area) (Calculations require consistent units of measure in these formulas)
22
Hydraulic Cylinders Speed at which the cylinder extends or retracts is determined by: Physical volume per inch of cylinder piston travel Amount of fluid entering the cylinder Effective area of the piston is used to calculate the volume of the cylinder per inch of piston travel
23
Hydraulic Cylinders Typical manufacturer’s catalog page
Bailey International Corporation
24
Hydraulic Motors Hydraulic motors are called rotary actuators
They convert fluid pressure and flow into torque and rotational movement
25
Hydraulic Motors Typical hydraulic motor application
26
Hydraulic Motors All basic hydraulic motors consist of three component groups: Housing Rotating internal parts Power output shaft
27
Hydraulic Motors Parts of a typical hydraulic motor
28
Hydraulic Motors System fluid enters the housing and applies pressure to the rotating internal parts This, in turn, moves the power output shaft and applies torque to rotate a load
29
Hydraulic Motors Primary parts that produce the rotating motion in most hydraulic motors are either: Gears Vanes Pistons
30
Hydraulic Motors Four requirements of a motor
31
Hydraulic Motors Displacement of a hydraulic motor indicates the volume of fluid needed to turn the output shaft one revolution Fixed displacement Variable displacement
32
Hydraulic Motors In a fixed-displacement motor:
Internal geometry cannot be changed Same volume needed per output shaft revolution
33
Hydraulic Motors In a variable-displacement motor:
Internal geometry can be changed Displacement per shaft revolution can be adjusted Motor can operate at variable speeds with a constant input flow
34
Hydraulic Motors Hydraulic motors may be classified by the type of load applied to the bearings of the output shaft Unbalanced indicates the output shaft is loaded from one side, side loading the shaft bearings Balanced indicates the bearing load is balanced by use of two inlet ports arranged opposite of each other and two outlet ports similarly arranged
35
Hydraulic Motors The external gear hydraulic motor is the most common and simplest of the basic motor types Fixed displacement Unbalanced load on the bearings
36
Hydraulic Motors The most common internal gear motor has a gerotor design Courtesy of Eaton Fluid Power Training
37
Hydraulic Motors The specially shaped gear teeth of the gerotor form variable-volume chambers that allow system fluid flow and pressure to turn the motor output shaft Gerotor motors are fixed-displacement units operating with an unbalanced bearing load
38
Hydraulic Motors An orbiting gerotor motor is a variation of the basic gerotor design Uses a fixed outer gerotor gear with internal teeth and an inner gear with external teeth Center point of the inner gear orbits around the center point of the fixed gear with internal teeth Motor operates at a slower speed, but has a higher torque output
39
Hydraulic Motors Orbiting gerotor motor
Courtesy of Eaton Fluid Power Training
40
Hydraulic Motors Basic vane motor has a slotted rotor located off center in a circular chamber and fitted with movable vanes Space between the vanes creates a number of variable-sized chambers Forcing fluid into the small-size chambers causes the volume of the chambers to increase, turning the motor shaft Basic vane motor is fixed displacement with an unbalanced bearing load
41
Hydraulic Motors Basic vane motor
42
Hydraulic Motors Balanced vane motors evenly distribute the load on the bearings Achieved by operating the rotor and vanes in a slightly oblong chamber Allows two inlet ports and two outlets ports to be used in the motor Placing ports opposite each other balances bearing loading
43
Hydraulic Motors A basic, balanced vane motor
44
Hydraulic Motors Vane motors are available as either fixed or variable displacement The variable-displacement feature allows an operator to change the speed of a motor without changing the system flow rate
45
Hydraulic Motors In variable-displacement designs, the chamber in which the rotor and vanes operate is contained in a moveable ring When the center point of the rotor and ring are concentric, the displacement is zero Moving the ring so the center points are not concentric increases the motor displacement and changes motor speed
46
Hydraulic Motors Piston motors are available having either fixed or variable displacements In variable-displacement designs, the length of the piston stroke is changed to vary the volume of fluid needed to rotate the motor one revolution
47
Hydraulic Motors Two basic classifications of piston motors are axial piston and radial piston An axial piston motor has pistons with centerlines parallel to the axis of the output shaft A radial piston motor has pistons with centerlines perpendicular to the axis of the output shaft
48
Hydraulic Motors Axial piston motor The Oilgear Company
49
Hydraulic Motors Axial piston motors are available in two configurations: Inline Bent axis
50
Hydraulic Motors In an inline piston motor:
Centerline of the barrel is concentric with the centerline of the power output shaft A swash plate transmits force from the pistons to the shaft
51
Hydraulic Motors Inline piston motor The Oilgear Company
52
Hydraulic Motors In a bent-axis piston motor:
Centerline of the barrel is at an angle to the centerline of the output shaft A universal joint and other fittings are used to transmit force between the barrel and the output shaft
53
Hydraulic Motors Bent-axis piston motor
Courtesy of Eaton Fluid Power Training
54
Limited-Rotation Hydraulic Actuators
Limited-rotation devices are actuators with an output shaft that typically applies torque through approximately 360° of rotation Models are available that are limited to less than one revolution, while others may produce several revolutions
55
Limited-Rotation Hydraulic Actuators
Most common designs of limited-rotation actuators are: Rack-and-pinion Vane Helical piston and rod
56
Limited-Rotation Hydraulic Actuators
Rack-and-pinion limited rotation actuator IMI Norgren, Inc.
57
Limited-Rotation Hydraulic Actuators
Vane limited-rotation actuator
58
Limited-Rotation Hydraulic Actuators
Helical piston and rod limited-rotation actuator
59
Limited-Rotation Hydraulic Actuators
Limited-rotation actuators are used to perform a number of functions in a variety of industrial situations Indexing devices on machine tools Clamping of workpieces Operation of large valves
60
Limited-Rotation Hydraulic Actuators
Limited-rotation actuators are used in this robotic arm IMI Norgren, Inc.
61
MDMA Equipment—Menomonie
Hydrostatic Drives Hydrostatic drive systems consist of the basic components typically found in other hydraulic motor circuits MDMA Equipment—Menomonie
62
Hydrostatic Drives Hydrostatic drives provide effective transmission of power and allow easy adjustment and control of: Output shaft speed Torque Horsepower Direction of rotation
63
Hydrostatic Drives When compared to conventional transmissions, hydrostatic drives: Have a high power output–to–size ratio May be stalled under full load with no internal damage Accurately maintain speed under varying load conditions Provide an almost infinite number of input/output speed ratios
64
Hydrostatic Drives Hydrostatic drives may be open or closed circuits
Open circuit has the layout of a basic hydraulic motor circuit Closed circuit has the outlet of the pump directly connected to the inlet of the motor and the outlet of the motor directly connected to the inlet of the pump
65
Hydrostatic Drives Open circuit design
66
Hydrostatic Drives Closed circuit design Sauer-Danfoss, Ames, IA
67
Formulae US customary system
68
Formulae Metric system
69
Additional slides for lecture
70
Hydraulic Cylinders Tie-rod cylinder
71
Hydraulic Cylinders External tie rod bolts are used to secure the ends on the tie-rod cylinder design Commonly found on heavy industrial machines External tie rods increase chance of damage and promote accumulation of dirt
72
Hydraulic Cylinders Mill cylinders Yates Industries, Inc.
73
Hydraulic Cylinders Threaded-end cylinder
Bailey International Corporation
74
Hydraulic Cylinders Typical hand-operated jack
75
Hydraulic Cylinders Telescoping cylinders are available for applications requiring long extension distances Rod is made up of several tubes of varying size nested inside of the barrel Each tube extends, producing a rod longer than the cylinder barrel Typical example is the actuator that raises the box on a dump truck
76
Hydraulic Cylinders Telescoping cylinders Star Hydraulics, Inc.
77
Hydraulic Cylinders Cylinders often use hydraulic cushions
Provide a controlled approach to the end of the stroke Reduces the shock of the impact as the piston contacts the cylinder head
78
Hydraulic Cylinders Cylinder cushioning device
79
Hydraulic Cylinders A variety of mounting configurations are used to attach the cylinder body and rod end to machinery Fixed centerline Fixed noncenterline Pivoting centerline Expected cylinder loading is the major factor in the selection of the mounting style
80
Hydraulic Cylinders Head-end flange mount
81
Hydraulic Cylinders Fixed-noncenterline mount
82
Hydraulic Cylinders Pivoting-centerline, clevis mount
83
Hydraulic Cylinders Pivoting-centerline, trunnion mount
84
Hydraulic Cylinders Hydraulic cylinder manufacturers provide detailed specifications concerning: Construction Physical size Load capacity
85
Hydraulic Cylinders This information includes basic factors such as:
Bore Stroke Pressure rating Other details, such as service rating, rod end configurations, and dimensions
86
Hydraulic Motors A number of alternate motor designs are used in specialized hydraulic applications Screw motor designs for quiet, continuous operation Special piston-motor designs allowing the direct mounting and drive of wheels for off-road, heavy-transport vehicles
87
Hydraulic Motors Hydraulic motors may be incorporated into circuits using series or parallel connections Series circuits: total system pressure is determined by adding the loads placed on each unit Parallel circuits: each motor receives full system pressure; loads must be matched or equal flow supplied to each motor if constant speed is desired from each unit
88
Hydraulic Motors Motors in series
89
Hydraulic Motors Motors in parallel
90
Hydraulic Motors Motors in parallel with flow control
91
Hydraulic Motors Braking circuits are used to slow hydraulic motors to a stop Inertia of a heavy rotating load can continue to turn the motor shaft Braking occurs when fluid discharged from the motor outlet port is forced to pass through an adjustable pressure control valve before returning to the reservoir
92
Hydraulic Motors Braking circuit
93
Hydraulic Motors An open-loop hydraulic motor system uses a layout typical of a basic hydraulic system Pump moves fluid from a reservoir, through a directional control valve, to the motor Fluid is then returned from the motor to the reservoir through the same control valve
94
Hydraulic Motors Closed-loop hydraulic motor systems continuously circulate fluid between the pump and the motor without returning it to a system reservoir These systems use a replenishment circuit to replace fluid lost through leakage
95
Hydraulic Motors Replenishment circuit
96
Hydrostatic Drives Four combinations of pump/motor arrangements can be used Fixed-displacement pump and motor Fixed-displacement pump and variable-displacement motor Variable-displacement pump and fixed-displacement motor Variable-displacement pump and motor
97
Hydrostatic Drives Fixed-displacement pump and motor:
Maximum horsepower, torque, and output shaft speed are fixed Pump and motor have fixed displacement, so these characteristics cannot be changed
98
Hydrostatic Drives Fixed-displacement pump and variable-displacement motor: Maximum horsepower is fixed Torque and speed are variable Due to use of a relief valve, efficiency is lowered Output shaft rotation may be reversed if the pump is reversible
99
Hydrostatic Drives Variable-displacement pump and fixed-displacement motor: Torque output is fixed Horsepower and output shaft speed are variable Output shaft rotation may be reversed if pump is reversible
100
Hydrostatic Drives Variable-displacement pump and motor:
Horsepower, torque, output shaft speed are variable Output shaft direction is reversible Most versatile of the four pump/motor combinations
101
Hydrostatic Drives Hydrostatic drives are typically considered hydrostatic transmissions when both the pump and motor have variable displacement This combination allows manual or automatic control of torque, speed, and power output
102
Hydrostatic Drives Two different general techniques are used in the construction of hydrostatic transmissions Integral Nonintegral
103
Hydrostatic Drives Integral construction combines all of the transmission parts into a single housing Nonintegral construction involves separate pump, motor, and accessories connected by hoses or tube assemblies
104
Review Question A(n) _____ cylinder can exert force during both the extension and retraction strokes. double-acting
105
Review Question A(n) _____ is the system component that converts fluid pressure and flow into linear force and movement. hydraulic cylinder
106
Review Question List the three basic configurations used to mount cylinders to equipment. A. Fixed centerline, B. fixed non-centerline, and C. pivoting centerline.
107
Review Question The three conceptual component groups that make up any hydraulic motor are: A. Rotor, vanes, and eccentric. B. Housing, rotating internal parts, and power output shaft. C. Housing, reciprocating internal parts, and power input shaft. D. Rotating internal parts, power input shaft, and power output shaft. B. Housing, rotating internal parts, and power output shaft.
108
Review Question To vary the displacement of a vane motor, a movable _____ is used to change the size of the pumping chambers. cam ring
109
Review Question List the four possible pump/motor arrangements that may be used with a hydrostatic system. A. Both pump and motor have fixed displacements, B. pump has a fixed displacement and the motor a variable displacement, C. pump has a variable displacement and the motor a fixed displacement, and D. both pump and motor have variable displacement.
110
Review Question During retraction, what is the effective area of the piston of a double-acting cylinder? The cross-sectional area of the piston minus the cross-sectional area of the rod.
111
Review Question A cylinder that has externally mounted metal rods holding the ends on the barrel is called a(n) _____ cylinder. tie-rod
112
Controlling the System
. Chapter 8 (Selected Topics) Controlling the System Pressure, Direction, and Flow
113
Objectives Explain the function of each of the three general types of control valves used in hydraulic systems. Compare the design and operation of direct-acting and pilot-operated pressure control valves. Describe the function of the various types of pressure control valves used in hydraulic systems.
114
Objectives Compare the design and operation of two-way, three-way, and four-way directional control valves. Describe the characteristics of the various spool configurations used in three-position directional control valves. List and compare the methods used to position control spools in valves.
115
Objectives Compare the design and operation of non-compensated and compensated flow control valves. Explain the effect fluid temperature and pressure variations have on the operation of flow control valves.
116
Primary Control Functions in a Hydraulic System
Control valves allow hydraulic systems to produce the type of motion or level of force needed to complete the functions expected of a hydraulic circuit
117
Primary Control Functions in a Hydraulic System
A variety of valves can control actuator direction, speed, and force output Used with permission of CNH America LLC
118
Primary Control Functions in a Hydraulic System
The three basic types of control valves are: Pressure control Directional control Flow control
119
Primary Control Functions in a Hydraulic System
Pressure control valves can: Protect the system from damage due to excessive pressure Sequence motion Limit pressure in selected sections of a circuit
120
Primary Control Functions in a Hydraulic System
A system pressure control valve
121
Primary Control Functions in a Hydraulic System
Directional control valves direct fluid flow to establish and control actuator movement Used with permission of CNH America LLC
122
Primary Control Functions in a Hydraulic System
Flow control valves control the operating speed of actuators They provide a means to vary the rate of fluid flow
123
Primary Control Functions in a Hydraulic System
A typical flow control valve
124
Basic Structure and Features of Control Valves
A fixed orifice is a precision hole either: Machined into the valve body or a component Pressed as a separate part into a valve passageway Both designs are used to control fluid flow
125
Basic Structure and Features of Control Valves
Fixed orifices
126
Basic Structure and Features of Control Valves
A spool is a cylindrical metal piece fitted into the bore of a valve body The spool is used to block or direct fluid through a valve to produce a desired fluid flow characteristic
127
Basic Structure and Features of Control Valves
A typical spool Used with permission of CNH America LLC
128
Basic Structure and Features of Control Valves
Internal and external forces are used to position the various valve elements Springs and pilot pressure are typical internal forces used to operate valve elements Manual, pilot pressure, and electromagnetic force are common external forces used for operation
129
Basic Structure and Features of Control Valves
Precision fit, rather than separate seals, is used to prevent excessive internal leakage in most hydraulic control valves Internal leakage must be drained from valve chambers Fluid buildup causes backpressure Backpressure prevents the proper operation of internal valve elements
130
Basic Structure and Features of Control Valves
Draining internal leakage
131
Basic Structure and Features of Control Valves
Internal and external drains are used to remove internal leakage Internal drains may be used when the outlet line is not subjected to system pressure External drains are connected to low-pressure return lines leading to the reservoir
132
Basic Structure and Features of Control Valves
Normal valve position refers to the position the internal elements assume when a hydraulic system is shut down Normally open Normally closed
133
Basic Structure and Features of Control Valves
Symbols for normally open and normally closed valves
134
Basic Structure and Features of Control Valves
Directional control valves may be referred to by the number of distinct flow positions provided by the valve Two position Three position
135
Basic Structure and Features of Control Valves
Symbols for directional control valves
136
Valve Operation and Springs, Fluid Pressure, and Fluid Flow
Springs, fluid pressure, and fluid flow are very important in the operation of hydraulic system control valves Springs are used in control valves to: Move spools and other internal elements Establish the maximum operating pressure Serve as a biasing force
137
Valve Operation and Springs, Fluid Pressure, and Fluid Flow
Common uses for springs
138
Valve Operation and Springs, Fluid Pressure, and Fluid Flow
Fluid pressure is used in control valves to: Directly open or close valves Remotely operate a valve element Operate a compensating device to obtain desired fluid flow
139
Valve Operation and Springs, Fluid Pressure, and Fluid Flow
Fluid flow through an orifice is used in control valves to establish differences in pressure These pressure differences combined with balancing pistons and biasing springs are commonly used in the operation of pressure and flow control valves
140
Pressure Control Devices
Pressure control valves may be grouped into one of five types System maximum pressure control Actuator sequence control Restrained movement control Pump unloading control Reduced pressure control
141
Pressure Control Devices
Control valves can be classified by internal modes of operation Direct operation Balanced-piston operation
142
Pressure Control Devices
Direct-operated valves depend on heavy internal springs to establish valve operating pressure Balancing-piston valves (compound relief valves) use lighter springs and system pressure acting on internal valve mechanisms to establish the desired operation
143
Pressure Control Devices
Typical direct-operated relief valve
144
Pressure Control Devices
Typical compound relief valve
145
Directional Control Devices
Directional control devices allow a system operator to control the direction of fluid flow in the system Starting and stopping of actuators Control of actuator movement direction
146
Directional Control Devices
Directional control devices can be grouped in four general classifications Shut-off or two-way valves Check valves Three-way valves Four-way valves
147
Directional Control Devices
Symbols for directional control valves
148
Directional Control Devices
The primary purpose of shut-off valves is to block fluid flow through a hydraulic system line Globe valve Gate valve Ball valve Spool valve Needle valve
149
Directional Control Devices
Typical globe valve
150
Directional Control Devices
Typical gate valve
151
Directional Control Devices
Typical ball valve
152
Directional Control Devices
Typical spool valve
153
Directional Control Devices
Typical needle valve
154
Directional Control Devices
The primary purpose of check valves is to allow free flow in one direction while preventing reverse flow Other functions include: Bypassing components during the return cycle of the system Providing flow resistance to maintain a minimum system pressure required for pilot operations
155
Directional Control Devices
Typical inline check valve
156
Directional Control Devices
Typical right-angle check valve
157
Directional Control Devices
Three-way directional control valves provide a means to extend rams and single-acting cylinders The actuator is returned to its original position by an external force System load Spring built into the actuator
158
Directional Control Devices
Typical three-way directional control valve
159
Directional Control Devices
During extension, the three-way valve connects the actuator inlet line to a system supply line, allowing fluid to enter and extend the unit During retraction, the valve blocks the supply line and connects the actuator line to a system return line, allowing external force to return the actuator to its original position while directing displaced fluid to the reservoir
160
Directional Control Devices
Four-way directional control valves provide a means to power actuators in either direction Valve has four external ports for connection to system supply line, reservoir, and inlet and outlet of the actuator Internal structure of the valve allows the ports to be alternately connected when a change in actuator direction is necessary
161
Directional Control Devices
Four-way valve powers double-acting cylinder during extension and retraction
162
Directional Control Devices
Four-way directional control valves are typically manufactured as two- or three-position valves This provides several operating options when designing circuits
163
Directional Control Devices
Typical two-position, four-way valve
164
Directional Control Devices
In two-position valves, the first position operates the actuator in one direction, while the second position reverses the direction In three-position valves, a center position is added that provides additional circuit operating characteristics
165
Directional Control Devices
Typical three-position, four-way valve
166
Directional Control Devices
A number of center position configurations are available Closed Open Tandem Floating Regenerative
167
Directional Control Devices
Symbols for four-way valve center position
168
Directional Control Devices
169
Directional Control Devices
170
Flow Control Devices Flow control devices produce the desired rate of actuator operating speed by controlling the volume of fluid allowed to reach the actuator Flow control devices can be divided into two general types: Restrictor Bypass
171
Flow Control Devices Restrictor-type flow control valves limit the volume of fluid through the valve Excess pump output is forced to return to the reservoir through the system relief valve
172
Flow Control Devices Circuit containing a restrictor-type flow control valve
173
Flow Control Devices Bypass type flow control valves use an integral control port to return excess pump output to the reservoir The returned fluid is at a pressure less than system relief valve pressure
174
Flow Control Devices Circuit containing a bypass-type (bleed off) flow control valve
175
Additional slides for lecture
176
Directional Control Devices
A standard check valve consists of a valve body containing a one-way valve located between inlet and outlet ports The one-way valve allows fluid flow through the valve in only one direction Some designs contain a spring that seats the valve poppet or ball In other designs, the poppet is seated only by fluid flow
177
Directional Control Devices
Restriction check valves allow free flow in one direction and restricted flow when flow direction is reversed This is accomplished via a metering orifice machined into the poppet
178
Directional Control Devices
Typical restriction check valve
179
Directional Control Devices
Pilot-operated check valves can allow reverse flow through the valve Typically, pilot pressure opens the valve In some designs, pilot pressure may also hold the valve shut to block flow in both directions
180
Directional Control Devices
Pilot pressure to open check valve
181
Directional Control Devices
Pilot pressure to block flow through valve
182
Directional Control Devices
For a three-position, four-way valve, there are number of center position configurations available Closed Open Tandem Floating Regenerative
183
Directional Control Devices
The center position affects directional control characteristics and overall system efficiency Each style provides distinct operating characteristics that allow hydraulic system designers to obtain maximum performance from a system
184
Directional Control Devices
A number of activation methods are used to shift the internal components of directional control valves Five general categories: Flow actuation Manual operation Mechanical operation Pilot operation Electrical operation
185
Directional Control Devices
Flow actuation uses internal fluid movement to actuate the valve No external mechanism or force is used
186
Directional Control Devices
Manual operation methods include: Handwheels Levers Push buttons Foot pedals These devices require constant operator presence and are typically found in less-complex systems
187
Directional Control Devices
Mechanical operation methods include: Rollers Cams Levers Rams Mechanical operation is often used when the opening and closing of the valve must occur at a specific position in actuator travel
188
Directional Control Devices
Circuit containing a mechanically actuated directional control valve
189
Directional Control Devices
Pilot operation uses system pressure to activate the valve, rather than physical labor This method is effective when: Larger forces are need to shift the valve Remote operation is required because of safety or tight physical factors
190
Directional Control Devices
Pilot-operated directional control valve Courtesy of Eaton Fluid Power Training
191
Directional Control Devices
Electrical control of hydraulic systems is common in many types of equipment Simple solenoid devices to shift basic valves Electronic controllers operate proportional solenoid valves to produce extreme accuracy and repeatability
192
Directional Control Devices
Typical electrically controlled valve The Oilgear Company
193
Directional Control Devices
Multiple-position directional control valve may be held in a desired position using springs or detents Springs are located on the ends of the valve spool to return the valve to its normal operating position
194
Directional Control Devices
Symbols for spring-return valves
195
Directional Control Devices
Detents are locking devices that hold the spool in a selected position The spool may be held until the operator manually shifts the valve Increased system pressure at the end of an operation may automatically shift detent valves back to the normal position
196
Directional Control Devices
Typical detent operation
197
Flow Control Devices Conceptual operation of a flow control valve may be traced to a basic orifice
198
Flow Control Devices The flow rate through a simple, sharp-edged orifice depends on: Area of the orifice Pressure difference between the inlet and outlet sides of the orifice Viscosity of the fluid, which varies with fluid temperature
199
Flow Control Devices Discharge coefficients are typically used in fluid mechanics formulas to simplify mathematical calculations These coefficients are available in most technical references covering fluid mechanics
200
Flow Control Devices Formula using a discharge coefficient to calculate flow through an orifice: Qa = Ao × Cd × 2 × g × H Where: Qa = actual quantity of flow Ao = cross-sectional area of orifice Cd = coefficient of discharge g = gravity H = head
201
Flow Control Devices Flow control valves may be noncompensated or compensated The flow rate through noncompensated valves varies as the load or fluid viscosity changes Compensated valves automatically adjust for fluid pressure variations to produce a consistent flow rate under varying load and temperature conditions
202
Flow Control Devices Noncompensated and compensated flow control valves may have: Fixed flow rate Adjustable flow rate
203
Flow Control Devices The simplest restrictor-type flow control valve is a simple orifice Basically a calibrated hole Serves as a noncompensated, fixed-rate flow control device
204
Flow Control Devices A needle valve is the simplest restrictor-type, noncompensated adjustable flow control device Consists of an orifice fitted with a tapered needle machined on a threaded stem Turning the threaded stem changes the effective area of the orifice, which adjusts the flow rate through the valve
205
Flow Control Devices Basic adjustable flow control valve
206
Flow Control Devices When using a restrictor-type, noncompensated flow control valve, actuator speed varies when system loads change Caused by the change in pressure drop across the control valve, which varies the flow rate through the valve
207
Flow Control Devices A pressure compensator maintains a constant pressure difference across the metering orifice of a flow control valve Senses pressure on the inlet and outlet sides of the orifice These pressures generate forces that act on the end surfaces of a sliding spool that is preloaded by a biasing spring
208
Flow Control Devices Force generated by the biasing spring establishes the constant pressure difference across the orifice This constant pressure difference maintains constant fluid flow through the valve even when system loads change
209
Flow Control Devices A basic pressure-compensated flow control valve
210
Flow Control Devices Pressure compensator operation
211
Flow Control Devices Pressure compensator operation
212
Flow Control Devices Temperature compensation is necessary in flow control devices if an accurate, consistent flow rate through a valve is needed This is due to the fluid viscosity changes that occur as fluid temperature changes
213
Flow Control Devices Temperature compensation is typically accomplished in flow control devices by: Specially designed, sharp edged orifice Heat-sensitive metal rod that operates a needlelike control device in the metering orifice of the valve
214
Flow Control Devices Temperature compensation using a heat-sensitive metal rod
215
Flow Control Devices In a circuit using a restrictor-type, pressure-compensated flow control valve: Pressure drop across the internal flow-control device in the valve remains constant, which produces a constant flow rate through the valve Actuator speed will not vary when system loads change
216
Flow Control Devices In a circuit using a restrictor-type, temperature-compensated flow control valve: Valve internal flow-control device is adjusted for viscosity variations that occur during fluid temperature changes Flow remains constant as system operating temperatures change
217
Flow Control Devices Circuit containing restrictor-type, compensated flow control valve
218
Review Question Control valves allow a hydraulic system to produce the type of _____ and level of _____ needed for machine operation. motion; force
219
Review Question Name the two types of pressure control valves that are used to prevent damage to hydraulic systems in cases where the system relief valve fails, causing excessive system pressure. A. Safety valve and B. hydraulic fuse.
220
Review Question What is the primary purpose of pressure control valves in a hydraulic circuit? To protect a machine and the hydraulic system components from damage caused by excessive pressure.
221
Review Question A four-way directional control valve has four ports. Describe what each port is connected to in the system. A. Pump discharge, B. cylinder or motor inlet, C. cylinder or motor outlet, and D. reservoir inlet.
222
Review Question Which type of a three-position, four-way directional control valve has a middle position with the pump, reservoir, and actuator ports connected? Open-center.
223
Review Question The _____ method of directional control activation uses system pressure, which may be remotely sensed, to shift the valve. piloting
224
Review Question What are the two general operating designs of flow control valves? A. Restrictor and B. bypass.
225
Review Question In an operating fluid power system, the _____ of the fluid will change as the operating temperature of the system changes. viscosity
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.