Presentation is loading. Please wait.

Presentation is loading. Please wait.

CDC Structure S. Uno KEK 2009.3.18.

Similar presentations


Presentation on theme: "CDC Structure S. Uno KEK 2009.3.18."— Presentation transcript:

1 CDC Structure S. Uno KEK

2 Endplate Design sBelle 350mm 300mm 250mm
MAPS = Monolithic Active Pixel Sensor 350mm 300mm 250mm 2

3 Wire stringing Vertical stringing with outer cylinder.
Human can stand inside the chamber and can touch the wire. Inner diameter without the small cell part : ~500mm N. Taniguchi confirmed it with a hand-made mockup. Stringing with tension can be done from outer layer. Two-way method ( Belle-CDC ) is not necessary.

4 Barrel PID

5 Backup

6 CDC structure Shoji Uno (KEK)    Dec-3rd, 2008

7 Baseline Design sBelle Belle MAPS = Monolithic Active Pixel Sensor 7

8 Main parameters Present Future 77 160 880 1140 88 172 863 1120 50 58
Radius of inner boundary (mm) 77 160 Radius of outer boundary (mm) 880 1140 Radius of inner most sense wire (mm) 88 172 Radius of outer most sense wire (mm) 863 1120 Number of layers 50 58 Number of total sense wires 8400 15104 Effective radius of dE/dx measurement (mm) 752 978 Gas He-C2H6 Diameter of sense wire (mm) 30

9 Wire Configuration Present CDC 250 mm 1200 mm New CDC 250 mm

10 Small Cell Drift Chamber

11 Photo of small cell chamber
Just after wire stringing Installation in 2003 summer

12 Curved Endplate Deformation of endplate due to wire tension was calculated at design stage of present Belle CDC (Total tension: 3.5 Ton). Deformation(mm) Present New

13 Weight Endplate Outer Cylinder Electronics Board
Al, Thickness : 10mm (12mm) 110kgx2 = 220kg (264kg) Outer Cylinder CRRP, Thickness : 5mm 210kg Electronics Board G10, 48ch/board 0.3kgx315 = 95kg

14 Present support

15 Calculation of deformation and etc
Deformation of Aluminum endplate Thickness of endplate  10mm  12mm Deformation 1/t  Tension of field wire  120g  80g Gravitational sag, Sense : 120mm(80g), Field:300mm(80g) Total tension 4.8ton       Stress calculation Thickness of outer cylinder CFRP:mm  Transition structure between endplate and outer cylinder Support structure Structure for wiring jig Simpler one as compared with Belle-CDC Etc.

16 Wire stringing Now, I am thinking a vertical stringing, not horizontal. Once, I thought the horizontal stringing Vertical stringing with outer cylinder. Human can stand inside the chamber and can touch the wire. Inner diameter without the small cell part : ~500mm Inner diameter of present transition cylinder : 580mm Stringing with tension can be done from outer layer. Two-way method ( Belle-CDC ) is not necessary.

17 Installation Removing and installation can be done using similar small bar in horizontal direction. Cathode installation in vertical direction CDC installation in horizontal direction

18 My Personal Plan for Construction


Download ppt "CDC Structure S. Uno KEK 2009.3.18."

Similar presentations