Download presentation
Presentation is loading. Please wait.
1
Hadron PID recalibration in EMCAL (Au-Au @200 GeV dataset)
Dipali Pal and Debsankar Mukhopadhyay 05/10/2005
2
Outline Run4 200 GeV Au-Au stripe –2 dataset PbSc east and west
Timing calibration was done by SUNY Phys. PID functions: isPi, isK and isP -- Fit mass-squared distributions at different momentum slices within 0.2 < p(GeV/c) < 2.2. -- Determine centroids and s’s of m2 distribution for pi, K and p at different momenta. -- Study and parametrize s vs p and centroid vs p. -- PID function: isN = [m2(measured) – m2(parametrized)]/s N = pi, K, p
3
Analysis Events: Minimum-bias CNT files |bbcz| < 30 cm
Tracks: 3s matching at PbSc Used Sarah’s EmcTof timing recalibrator via master recalibrator module under fun4all.
4
Studying PbSc PID ranges from m2 distributions (Negative tracks) -- 1
5
Studying PbSc PID ranges from m2 distributions (Negative tracks) -- 2
Summary: PID starts from p = 0.3 Gev/c Protons are visible from p = 0.5 GeV/c All p, K, p are separated within 0.5 – 1.0 GeV/c p and K are separated within 0.3 < p (GeV/c) < 1.0 Both p and p are visible upto p = 2.0 GeV/c
6
Studying PbSc PID ranges from m2 distributions (Positive tracks) -- 1
7
Studying PbSc PID ranges from m2 distributions (Positive tracks) -- 2
Summary: PID starts from p = 0.3 Gev/c Protons are visible from p = 0.5 GeV/c All p, K, p are separated within 0.5 – 1.0 GeV/c p and K are separated within 0.3 < p (GeV/c) < 1.0 Both p and p are visible upto p = 2.0 GeV/c
8
m2 distributions and fitting – p(1)
Fitting function: Gaussian (signal)+ second order polynimial(BG) Centroids and s’s within 0.4 < p(GeV/c) < 1.2 GeV/c
9
m2 distributions and fitting – p (2)
p <m2> Dm s Ds e e e e-06 e e e e-06 e e e e-06 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-04 e e e e-04 e e e e-04 e e e e-04
10
m2 distributions and fitting – p (3)
p <m2> Dm s Ds e e e e-06 e e e e-06 e e e e-06 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-05 e e e e-04 e e e e-04 e e e e-04
11
m2 distributions and fitting – Kaon
Fitting function: Gaussian (signal)+ Exponential (BG) Centroids and s’s within 0.4 < p(GeV/c) < 1.0 GeV/c
12
m2 distributions and fitting parameters: K+
p <m2> Dm s Ds e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04
13
m2 distributions and fitting parameters: K-
p <m2> Dm s Ds e e e e-04 e e e e-05 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04
14
m2 distributions and fitting – protons
Fitting function: Gaussian (signal)+ Exponential (BG) Centroids and s’s within 0.5 < p(GeV/c) < 2 GeV/c p-bar looks different from p at higher momenta.
15
m2 distributions and fitting parameters
anti-proton proton p <m2> Dm s Ds p <m2> Dm s Ds e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-03 e e e e-04 e e e e-03 e e e e-03 e e e e-03 e e e e-03 e e e e-03 e e e e-03 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-04 e e e e-03 e e e e-03 e e e e-03 e e e e-03 e e e e-03
16
m2 Centroids vs momenta Centroids are fitted with 3rd order polynimial
as functions of p: p0 + p1*x + p2*x2 + p3*x3 p p p p3 p+ p- K+ K- P P-bar e e e e-02 e e e e-02 e e e e-01 e e e e-01 e e e e-02 e e e e-02
17
Sigma vs momentum: pion
Fitting function: p0 + p1/x + p2/x2 + p3.x2 p p p p3 p p
18
Sigma vs momentum: kaon
Fitting function: p0 + p1/x + p2/x2 + p3.x2 p p p p3 K K
19
Sigma vs momentum: proton
P-bar Fitting function: p0 + p1/x + p2/x2 + p3.x2 p p p p3 p p-bar
20
Identified particles
21
Summary PID calibration functions are completed for run4 200 GeV dataset. Need to put them in recalibrator and database.
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.