Looks normal Elevated scan readings suggest other wise
2
Timber assessment required Endoscope inserted to check timber What is should look like What it did look like - Rot
3
Removed the lining
4
Removed more lining Looks worse than it is.. Damaged is localised and is caused by failed window corner seals
5
Yuk Boundary Joist destroyed. BUT it doesnt take long to cut it out with out damaging the exterior
6
Boundry joist removed Boundary Joist removed
7
New treated timber installed New Boundary joists installed
8
Timber replaced
9
Nearly finished From start to finish has taken two days
10
Finished Important points This job took 2 days The frame is back to normal The windows have been resealed. No need to reclad Monitor regularly