Download presentation
Presentation is loading. Please wait.
1
NSA-7000 Stylish flush mount Network Sensors
Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Stylish flush mount Network Sensors Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’
2
NSA 7000 Network Sensors flush mount Overview
Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA 7000 Network Sensors flush mount Overview The new platform changes the look of our room sensors. NS-7000 Network Sensor NSA-7000 Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages
3
NSA 7000 Network Sensors flush mount Overview
Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA 7000 Network Sensors flush mount Overview The Hardware platform provides: NSA7000 New Network Sensor (SA-Bus) Standard Version Black Optional Benefit Modern design Large display with Push buttons Thin profile 14 mm and square 86 x 86 mm design Flush mount, made to fit EU box White Front Panel, optional Black (MOQ500 pcs *) Configurable functions for SKU reduction and easy selection Combined Temperature and Humidity detection Consistent design between new generation of Room Sensors Flush mount European Box Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages
4
NSA-7000 User Interface Large Display Custom Display Fan Controls
Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA User Interface Large Display Custom Display 40% of the front area Backlight with time-out No need of localization Show Set Point only option Show Humidity Set Point limits Show Units °C or F Temperature reading offset Fan Controls Set Point Control Depending on model Easy selection up / down of 0,5 °C Set Point mode ADJ or W/C configurable Occupancy Toggle OCC output ADJ 12 28 °C W/C -3 +3 Configurable Up to 5…35°C Up to °C SP MODE Keypad Lockable No lock Lock all keys Lock all keys except Occupancy Press and Hold 5 SEC to configure Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages
5
NSA7000 Network Sensor Overview
Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA7000 Network Sensor Overview Network Sensor A7000 (NSA700) Designed for SA-BUS use same tool of current Network Sensors NS7000 Main Difference versus Current NS7000: Flush mount, larger display and low profile enclosure All models have Screw Terminal (ST) and Modular Jack (MJ) Local configuration via Display and pushbuttons: SA-BUS Address, can be done without open the sensor through the Display Configurable Set Point mode: Adjust or Warmer/Cooler (1 code can do both) Configurable Display to show Setpoint only instead actual temperature Mounting plate allows installation without open the device Locks Push buttons 4 Items codes for many configuration ST MJ Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ Company Confidential, do not disclose outside of the Company
6
NSA7000 Analog Sensors Items codes
Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA7000 Analog Sensors Items codes NSA-FTD7003-0 Four buttons model NSA-FTB7003-0 Three buttons model Temperature Set Points ADJ or W/C Fan Speed Occupancy Connection MJ + ST Address # Temperature Set Points ADJ or W/C Occupancy Connection MJ + ST Address # NSA-FHR7103-0 Three buttons model NSA-FHN7001-0 Temperature and Humidity Set Points ADJ or W/C Occupancy Connection MJ + ST Address # Temperature and Humidity Connection MJ + ST Single Address #199 Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages
7
NSA7000 Network Sensors Installation
Header - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA7000 Network Sensors Installation The NSA-7000 can be installed on rounded European boxes using the mounting plate included in the supply. Once installed the devices will cover completely the mounting plate and it will protrude from the wall of 14 mm only. A little screw keeps the device in place. Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’ NSA-7000 Network sensor Resource pages
8
NSA-7000 Ordering codes Table 1: NSA7000 series network – Standard Devices White Product code Color1 LCD Temperature Humidity2 Fan control Temp. adjustment3 °F/ °C scale toggle Occupancy override Screw terminal4 Address selection5 NSA-FHN7001-0 White No Yes Yes (±3%) N/A ST/MJ No (#199) NSA-FTD7003-0 Adj/WC NSA-FTB7003-0 NSA-FHR7103-0 Table 2: NSA7000 series network – Optional Black Devices Product code Color1 LCD Temperature Humidity2 Fan control Temp. adjustment3 °F/ °C scale toggle Occupancy override Screw terminal4 Address selection5 NSA-FHN7011-0 Black No Yes Yes (±3%) N/A ST/MJ No (#199) NSA-FTD7013-0 Adj/WC NSA-FTB7013-0 NSA-FHR7113-0 Note: There is MOQ (Minimum Order Quantity) requirement for black color. For models with humidity sensor, the humidity value can be displayed in LCD too Adj/WC means this model can work under Adjust 12 to 28°C or WC (Warmer/Cooler) +3 °C mode, selected in setting. All models equipped with both ST (Screw Terminal) and MJ (Modular Jack). The address can be selected from the display ( ). Default address is 199. Recommended number of device in a mixed bus is four. NSA-7000 Network sensor Resource pages
9
NSA-7000 network sensor Benefit
Large backlit Display in a low profile enclosure Display larger than 40% of front area, provides real time status of the environment with intuitive and clear user interface Display helps to meet building policy Sensors can be configured to show temperature, humidity or set point only, in addition the keypad can be locked to avoid misuse in public spaces. Flush Mount installation make it stylish Suitable for various installation boxes, flush mount offer low profile of only 14 mm outside the wall. Customize colors to meet customer needs The front panel of the sensor can be white or customized in black or other colors with a minimum quantity. Programmable SA Bus Address. User can easy define and read the communication address via push button, without opening and disconnecting the device. Mounting plate protection cap The mounting plate allows installation without opening the sensor. The removable and repositionable protection cap protects the sensor during commissioning or painting. Both avoid the risk of component damages during installation Configurable options reduce stock need Setpoint functionality Adjust or Warmer/Cooler can be configured from the display during the installation. Easy Wiring with MJ and ST options All NSA7000 models offer both type of connections: Modular Jack (MJ) and Screw terminal (ST). NSA-7000 Network sensor Resource pages
10
NSA-7000 Technical Specification
Supply Voltage 9.8 to 16.5 VDC; 15VDC nominal (from SA Bus) Current consumption 35mA maximum Terminations Modular jack and screw terminal block Sensor addressing All models with factory set address 199. NSA-FTD70X3-0, NSA-FTB70X3-0 and NSAFHR71X3-0 can set address from 199 to 215 in setting page Wire size Modular jack: 24 AWG or 26 AWG (0.5 or 0.4 mm diameter) recommended; Three twisted pair (six conductors) Screw terminal block: AWG ( mm diameter); 22AWG (0.6 mm diameter) recommended Communication rate Auto-detect: 9.6k, 19.2k, 38.4k or 76.8k bps Mounting Flush-mounted Temperature measurement range 0-40 °C Humidity measurement range Full range: 0-100% RH Temperature accuracy ±0.5℃ (±1oF) Humidity accuracy ±3%RH Default temperature set point adjustment range Default Adjust Range: °C, max configurable °C in 0.5 °C increments Default W/C Range: -3 to +3 °C, max configurable + 0,5 to + 5 °C in 0.5 °C increments Ambient conditions Operating: 0-40 °C with 10-90% RH, non-condensing Storage: -20 to 60 °C with 5-95% RH, noncondensing Shipping weight Approx. 300g Compliance CE mark RCM mark, Australia/NZ emissions compliance RoHS, REACH, WEEE Footer - Use 'Insert >Header & Footer' to modify this text and ‘Apply to all’
11
Thank You NSA-7000 Network sensor Resource pages