Inline Granulation of Stretch Film
Precision AirConvey Team 5 Jordan Bellomo Victor Castro Stephen Koellhoffer Zachary Magnone Matthew Manzione
2
Outline Problem Definition Current System Concept Selection
Detailed Design Fabrication Construction Test Set Up / Testing Path Forward
3
Problem Definition System Function Proposed Problem
Remove, Reprocess, Recycle Stretch Film Proposed Problem Competition has a similar, but more efficient system Uses less machinery Converts ribbon directly to fluff, with no intermediate steps PAC is in danger of losing valued customers
4
Current System
5
Concept Goals Reduce amount of machinery Reduce system cost
Eliminate initial cutter Reduce to one fan Reduce system cost Manufacturing cost Operating cost Feasible to manufacture
6
Best Concept Features Diverts some air away from material Simple
Adjustable Easy to implement Based on existing technology
7
Concept Refinement Several Feasible Ideas
Vertical Inlet, Cylindrical Screen Vertical Inlet, Slanted Screen Vertical Inlet, Dual Sided Slanted Screen
8
Material and some air flow OUT
Concept Refinement Best Concept Cylindrical enclosure, conical screen Pressure membrane distributes airflow Material and some air flow OUT Flow restriction membrane Conical screen, 50% open area Low pressure Zone Separated air OUT 100% Air and Material IN
9
Detailed Design
10
Detailed Design Dimensional justification
Used PACs existing screen separator as a starting point for our design Maintained same open area of screen Used approximately same screen angle
11
Fabrication Created detailed design of separator
Sent drawings to PAC’s fabricator Received finished Prototype
12
Construction Attached all system components
13
Test Set Up Victor
14
Testing Measurements Taken: Target Values
Pressure: Total Drop ≤ 25 in. H2O Air Velocity: ~6500 ft/min. Air Pulled Through Grinder: ≥ 1000 cfm Fan Power: ≤ 60 Hz Bulk Density of End “Fluff”: 4-7 lb/ft3 Material Velocity: ~2000 ft/min.
15
Testing Concept Validation Diversion of air was necessary
Theoretical calculations match experimental results Diverting some airflow Increased system efficiency Reduced fan speed Increased airflow at inlet Pressure membrane was not critical Conical screen provided enough of a restriction
16
Granulation Success: The Rise and Fall of Stretch Film
Testing Granulation Success: The Rise and Fall of Stretch Film
17
Path Forward Compile data CD with all relevant project data for PAC
Longer length tests need to be conducted Install access panel for cleaning purposes Experiment with different conical screens May be able to further increase system efficiency
18
Summary Problem Definition Current System Concept Selection
Detailed Design Fabrication Construction Test Set Up / Testing Path Forward
19
Questions ?