PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: +62 21 8835 7506 / Fax +62 21 8835 7507, Web: www.global9-ind.com PRESENTED BY: NetMACS II TM
4
The NetMACS II is a flexible and cost effective solution to monitoring locations ranging from confined area such as cabinet to large and diverse environments such as central offices. The NetMACS II can be programmed to perform local control and evaluation such as threshold based alarming and trending. It can also be used to program complex algorithm-based decision making. Data can be accessed graphically via a standard web browser over a network. Using this web interface, commands and changes to setpoint can be input through pushbuttons and slide bars 24 – 768 Inputs Automatic range selection monitors inputs from 60VDC to battery float current levels via a 50mV shunt. Isolated Outputs Four isolated relay drivers and two isolated analog output. 0.5% Accuracy of Analog Data 1U Rack Height 19 or 23 rack or wall mountable Modem/Network Compatible Web Based Communication capability including e- Mail alert messaging. The NetMACS II is capable of monitoring all plant voltages and signals. It can produce a status report for these voltages and signals in over specified of the plant operation. This gives the user the capability to track a plant performance over a long period of time. A basic NetMACS has 24 universal inputs, 4 isolated relay drivers and 2 isolated analog outputs. This input will automatically switch from a 60VDC range to a 50mV range (accuracy of 0.5%, with a resolution of 20 microvolts in the 50mV range). This basic functionality can be expanded by adding suplemental monitoring units, up to a total of 768 inputs. NetMACS TM II Control and Monitoring System Monitoring Product Description
5
The NetMACS II operating system allows the programmer to create functional control programs. These programs can be site specific and based upon the values of any or all Analog Inputs, Analog Outputs, Timers, Digital Input Registers, Function and status of any or All Digital Input, Digital Outputs, Date, Time of Day, etc. These program can be started either automatically, manually with a switch or remotely with a macro. Programming The NetMACS II has wide array of communication capabilities. These include: Ethernet 10 base-T running TCP/IP * Http Web enabled * SNMP upgradeable Communications Typical Programs Power Plant Controls Automatic Equalizing * Battery Thermal Protection Load Shedding * Time Schedulling Spare Rotation * Runtime Logging Trend Logs * Automatic Status Reporting Monthly Report Environmental Controls Fixed Time Duty Cycling * Night Purge Lead/Lag Control * Seasonal Change-over Duty Cycling * Optimum Start/Stop Staging Control * Security System Control AC Generator Test The NetMACS II units, when parameter are established, can control the plants performance characteristics. Controls
7
Software NetMACS II Control & Monitoring System Basic Module with Max. 31 Supl. Module DC Power Plant Plumbing System Fire Alarm System Security System AC Plant Manual Control Lighting System Email Email Alert Visual Alert Audible Alarm Functional Programs Spare Rotation Load Shedding Auto Equalizing Remote ON/OFF Remote Equalizing Periodic Report Trend Logging Event Logging Network Control&Monitoring Typical Configuration SMS SMS Alert Power System Security System Fire Alarm System,ETC SMS SMS Control Call Phone Call
8
Lighting System Plumbing System Single Site Configuration (Example) NetMACS II Control & Monitoring System Basic Module (24 Input, 6HW Output) 2X Suplementary Module (48 Input, 12 HW Output) 2X Suplementary Module (48 Input, 12 HW Output) Security System 3X Suplementary Module (72 Input, 18 HW Output) Fire Alarm System 3X Suplementary Module (72 Input, 18 HW Output) Vacant 15X Suplementary Module (360 Input, 90 HW Output) Antena System 2X Suplementary Module (48 Input, 12 HW Output) AC Power System 2X Suplementary Module (48 Input, 12 HW Output) DC Power System 2X Suplementary Module (48 Input, 12 HW Output) Regional World Wide Network Local Direct Connection
9
Monitoring Display (Single Site) EXIT
10
Monitoring Display (Contd) (Single Site)
11
Control & Monitoring Display (Single Site) TYPE : PECO II 3874B NOM CAPACITY : 200 LOAD : 87.5 AMP VOLTAGE : 53.50 VOLT TEMP : 35.8 DEG C RFA STAT : OFF TYPE : PECO II 3874B NOM CAPACITY : 200 LOAD : 87.5 AMP VOLTAGE : 53.50 VOLT TEMP : 35.8 DEG C RFA STAT : OFF TYPE : PECO II 3874B NOM CAPACITY : 200 LOAD : 87.5 AMP VOLTAGE : 53.50 VOLT TEMP : 35.8 DEG C RFA STAT : OFF TYPE : PECO II 3874B NOM CAPACITY : 200 LOAD : 87.5 AMP VOLTAGE : 53.50 VOLT TEMP : 35.8 DEG C RFA STAT : OFF ON
13
NetMACS II Control & Monitoring System Basic Module with Max. 31 Supl. Module Network Site No.1 Software Typical Configuration Power System Security System Fire Alarm System,etc (Multi Site) NetMACS II Control & Monitoring System Basic Module with Max. 31 Supl. Module Site No.2 Site No.3 Site No.4 Site No.5 Site No.XX Database NetMACS II Control & Monitoring System Basic Module with Max. 31 Supl. Module NetMACS II Control & Monitoring System Basic Module with Max. 31 Supl. Module NetMACS II Control & Monitoring System Basic Module with Max. 31 Supl. Module NetMACS II Control & Monitoring System Basic Module with Max. 31 Supl. Module Site No.5 Master Control Centre Mobile C&M
14
Control & Monitoring Display (Multi Site) Site #1: SGI-DM Normal Minor Major Ctritical Site #2: SGI-Ancol Normal Minor Major Ctritical Site #3: SGI-MDN Normal Minor Major Ctritical Site #4: SGI-SBY Normal Minor Major Ctritical Site #5: SGI-BLI Normal Minor Major Ctritical Site #6: BTS-CBR Normal Minor Major Ctritical Site #7: BTS-CKG Normal Minor Major Ctritical Site #9: BTS-MKS Normal Minor Major Ctritical Site #10: LOC-MND Normal Minor Major Ctritical Site #11: LOC-SMD Normal Minor Major Ctritical Site #12: LOC-BJD Normal Minor Major Ctritical Site #13: LOC-PTK Normal Minor Major Ctritical Site #14: LOC-MTR Normal Minor Major Ctritical Site #15: LOC-KPG Normal Minor Major Ctritical Site #17: BTS-BDG Normal Minor Major Ctritical Site #18: BTS-CMH Normal Minor Major Ctritical Site #19: BTS-SKB Normal Minor Major Ctritical Site #20: BTS-CRB Normal Minor Major Ctritical Site #21: BTS-PWT Normal Minor Major Ctritical Site #22: BTS-JGK Normal Minor Major Ctritical Site #23: BTS-MLG Normal Minor Major Ctritical Site #8: BTS-BGR Normal Minor Major Ctritical Site #16: BTS-CBT Normal Minor Major Ctritical Site #24:BTS-SMG Normal Minor Major Ctritical