1 HEMODYNAMIC SIMULATOR II P09026
MEs EEs Joseph Featherall: Lead Engineer Gaurav Zirath: Project Manager Mark Frisicano Alex Baxter Liliane Pereira Clarissa Gore Jonathan Peyton

2 Hemodynamic Simulator II (P09026)
Project Overview P09026 is continuation of project P08026, carried out during 2007/2008 academic year. Major Objectives Refinement of pump design Refinement of instrumentation and data acquisition software Research and development of computer control of all system parameters MSD I Fall '08 11/13/2018

3 Hemodynamic Simulator II
Project Deliverable Blood flow simulator Portable Aesthetically appealing, Able to replicate the operations of human heart (left-ventricle) Graphical User Interface (GUI) Simple to operate Displays the output data in desired form Provides users full control of the unit MSD I Fall '08 11/13/2018

4 Hemodynamic Simulator II
Specifications Engr. Spec # Specification Quantity Unit of Measure ES4 Heart Rate (HR) Beats Per Minute ES7 Left Ventricular Pressure (LVP) 0 – 120 mmHg ES8 Systolic Ejection Period (SEP) 400 ms (milli seconds) ES9 – ES12 Size of Overall System 21.5 x 38.5 x 72 Inches ES 16 Control Software LabVIEW - ES 19 Easy to drain 2 people max. MSD I Fall '08 11/13/2018

5 Hemodynamic Simulator II
Specifications (Control System) MSD I Fall '08 11/13/2018

6 Hemodynamic Simulator II
Overall System Architecture MSD I Fall '08 11/13/2018

7 Hemodynamic Simulator II
Pump Design: Designs / Schematics Buffering Chamber Aortic Chamber Atrial Chamber MSD I Fall '08 11/13/2018

8 Hemodynamic Simulator II
Pump Design: Designs / Schematics Heart Stand MSD I Fall '08 11/13/2018

9 Hemodynamic Simulator II
Technical Risk Assessment Pump Design Actuator not function at its optimal level Excessive compliance in the circulatory loop Fluid inertia may cause delay from input to output Control System LabVIEW: no previous experience Length of testing MSD I Fall '08 11/13/2018

10 Hemodynamic Simulator II
Current State of Design Pump Design Pump design meets all customer needs. Initially chosen actuator, not powerful enough. Maximum HR spec. was lowered from 220 to 120 bpm. Current actuator package meets all customer specs & design requirements. Manufacturing parts All material priced & sourced , will be ordered this week. Atrial, aortic & compliance chambers to constructed over thanksgiving break. Control System Two weeks behind schedule due to system modeling. Developed a test plan for the control system as well as the overall system. Plans to start building and testing over break MSD I Fall '08 11/13/2018

11 Hemodynamic Simulator II
Finances Budget $ 3k Bill of Materials $ Pump Design Actuator Package: $ Mechanical Components: $ Control System Design Data Acquisition Board $ MSD I Fall '08 11/13/2018

12 Hemodynamic Simulator II
MSD II Schedule/Milestones Week 1 (12/01/08) Finalize manufacturing of parts Week 2 (12/08/08) – Week 4 (12/22/08) Begin prototyping & data collection Continue data collection Based on empirical data, begin development of control system Week 5 (01/05/09) Finalize control system concept Mitigate all mechanical, electrical issues Week 6 (01/06/09) Begin preliminary testing Week 7 (01/13/09) Final testing of the overall system Week 8 (01/20/08) Finalize all connections Compile all documentation MSD I Fall '08 11/13/2018