Transformer Efficiency
2
The relationship that we derived for the transformer is:
3
If the transformer is 100% efficient all, ALL of the electrical power generated across the primary winding must be delivered to the secondary winding: As P= IV For a totally efficient transformer Pp = Ps i.e. IpVp = IsVs
4
The ratio: Therefore measures the efficiency of the transformer.
In practise large power transformers have an Efficiency of around 98%
5
Question The primary coil of a step down transformer has 5000 turns and the secondary coil has The primary has 1150V across it. Calculate the e.m.f. generated in the secondary coil. The transformer is 90% efficient. Calculate the average current generated in the secondary coil.