1 SMP Solution under the hood
Rob Guzikowski Echelon Confidential

2 SMP Solution Image EES Rapid Deployment SMP Solution has:
Good solution for replicating tested SmartServer solutions Supports LNS or Standalone Managed systems Solution is Standalone mode! Falls short on site variability User experience could improve SMP Solution has: Custom DRF files – EnergyApps2d.* Channel definitions – Names matter Virtual device – with special solution FPMs Web UI elements onboard Device/Modbus templates on board Web binder target connection

3 SMP Solution Image SMP Solution is custom has
Intricate Web bindings to support LonManager FPM Data update driven vMeter points in the data log Custom .fac files to support ‘Factorydefaults’ console command Pending app note on how to create! What the image does NOT have Instances of Modbus or Lonworks metering devices CPs with drive the vMeter APP are not initialized

4 SPM Solution Modbus and LonWorks devices templates
150s poll interval targeted data Special markup in UCPTdescription for vMeter APP vMeter data points poll external data points to create meter point bundles that as space delimited values. Updates drive the Logging! 16 supported in this solution PMU will be a different APP (one/PMU) Data Logs delivered to Serious Energy using Web bind LonManger APP

5 SMP Apps LogManager APP vMeter APP (x16) Web Bind Traget

6 LogManager Use Web Bind
Internet Web Server/SOAP Service SMP Site Log Parser SQL HTTP SOAP Web Bind Request

7 LogManger FPM Status Data Purge External Web Bind Internal Web Bind

8 LogManager APP Configuraton

9 SMP vMeter APP Periodically polls meter points defined by a configuration file Bundles values in a defined order, as value separated strings UNVTvMeterData – 220 byte string! Writing the bundled value results in a log entry Points read and bundled only on configured vM<x> FB Invalid values written when points go offline No API to update point status.

10 SMP vMeter APP Config File Poll /Log Interval Data Bundle

11 SMP vMeter APP Configuration

12 SEM Adapter Wizard Build on the SMP SmartSever Wizard framework to generate the SEM context and deliver via web bind attachment XML formatted data Defines site address, load types, capacity, square footage….

13 SEM Adapter Data Model

14 SMP SEM Adapter Data File

15 SMP SEM Adapter After running the SEM Adapter wizard, the SeriousConf.xml file is transferred to the /data directory of the iLON. A web bind delivers the file to the SEM server Actually LNS_Proxy DS_Write web service Directory watcher application on the server sees the new folder and builds the SEM context for the site

16 SMP Process Purchase the SMP Model SmartServer
Electrical install for meters as required. Chose for the Select set of supported meters CTs matched to service Modbus network wired and configure Setup IP settings for the site IP network Behind the firewall no problem Run the Energy Insight Wizard Run the SEM Adapter Wizard Verify