Trane Care Energy RTHD Adaptive Frequency Drive retrofit
2
Preventive maintenance
Service business Chiller life cycle TURNKEY Equipment Replacement START-UP Chiller lifetime Comissioning Elite Start Preventive maintenance Trane Select Upgrade & improve Trane Care Maintain & repair Genuine parts
3
Service business Trane Care portfolio RELIABILITY ENERGY ENVIRONMENT
Oil analysis Vibration analysis Compressor R’newalTM Tube testing Exchanger enhancement Thermography Automatic tube cleaning Power factor correction Chiller control retrofit Adiabatic cooling Heat recovery Adaptive frequency drive Leak testing Refrigerant management Refrigerant monitor Refrigerant retrofit Noise reduction Indoor air quality
4
Building energy consumption
Energy breakdown HVAC systems frequently represent a large part of a building energy consumption. Chiller itself has a significant impact on the utility bill (~20%). Typical building consumption breakdown Chiller plant consumption breakdown
5
Building energy consumption
Chiller operation Chillers are selected at most unfavorable conditions. 99% of the time, chillers operate at part load. Improving part load efficiency is key to reduce building energy consumption. Monthly typical load in comfort application Selection conditions
6
Building energy consumption
Chiller solution to improve part load efficiency For decades Trane has used slide valve capacity control to: Adapt chiller capacity to building needs Reduce power input at part load Technology providing best in class efficiency New solution: Adaptive Frequency Drive Reduce compressor speed Adjust compressor speed to building needs Keep unmatch full load efficiency and reach best in class part load efficiency
7
Adaptive Frequency Drive
New life for existing chiller Variable speed drive Up to 35% chiller efficiency improvement Reduce inrush current Increase chiller reliability in reducing start & stop Tracer UC800 Intuitive navigation through color touchscreen display Immediate, easy to read, chiller information Automatically collect chiller information to build operating trends
8
Adaptive Frequency Drive
Inrush current comparison Make best use of electricity Reduce energy costs Up to 35% efficiency improvement Trust your electrical devices Low inrush current reducing electrical disruption Satisfy utility provider requirements Constant power factor correction Low harmonic distortion Efficiency comparison 25% 50% 75% 100% Savings area Inrush current comparison Legend Without AFD With AFD
9
Adaptive Frequency Drive
New generation control: TRACER UC800 Dynaview Touchscreen Black & White Screen dimensions: 4’ Main processor integrated to display Adaptiview Touchscreen Color Screen dimensions: 7’ Main processor in the control panel
10
Adaptive Frequency Drive
Clear and effective display Easier maintenance 7’ touchscreen color display Clear and detailed chiller information Operational effectiveness Data trending Clear alarm log TIS enable for remote monitoring Home screen Temperature trends
11
Energy consumption reduction
What it means to your utility bill? Office building in Spain with a 1000 kW chiller Monthly chiller consumption BEFORE AFTER