Download presentation
Presentation is loading. Please wait.
1
Heating of Magnesium Plates
By: Jonathan Scott
2
Introduction
3
The Problem Constant temperature profile needed Press pulls away too
much heat
4
Desired failure mode Undesired failure mode
5
Assumption No contact resistance between press and magnesium plate
Lumped Capacitance Room temperature = 298 K Open convection on all exposed surfaces
6
The Solution Tmax = 150 C or roughly 425 K Tf = 362 K Ra = 4.35x10^5 Nu top = Nu bottom = 6.93 h = W/mK Heat loss thru Natural Convection = 39.9 W Heat loss thru Conduction = 63.3 W
7
Conclusion Total Heat loss = 103.2 W
103.2 W must be applied at the press to increase Ts at that point