On the Seametrics MJ-Series Pulse Meter
Changing Pulse Rates On the Seametrics MJ-Series Pulse Meter
2
Setting Your Pulse Rate
11/15/2018 Setting Your Pulse Rate Pulse rate is determined by which sensor was ordered from the factory (single reed switch, dual reed switch, or single Hall-effect) and by the dial on which the magnetic pointer is located. Magnetic Pointer The magnetic pointer has a small metal rectangle attached to it (the magnet) and may be located in any of the dial positions. Seametrics Internal and Confidential
3
Setting Your Pulse Rate
11/15/2018 Setting Your Pulse Rate The magnetic pointer is set at the factory but can be easily changed in the field Mouse-over & click play to see again. Seametrics Internal and Confidential
4
Setting Your Pulse Rate
11/15/2018 Setting Your Pulse Rate Locate meter size in Column 1 Seametrics Internal and Confidential
5
Setting Your Pulse Rate
11/15/2018 Setting Your Pulse Rate Find desired pulse rate in Column 2 Seametrics Internal and Confidential
6
Setting Your Pulse Rate
11/15/2018 Setting Your Pulse Rate Note magnet pointer position in Column 3 Seametrics Internal and Confidential
7
Moving the Magnetic Pointer
11/15/2018 Moving the Magnetic Pointer Cut and remove the MJ meter’s security wire. Security Wire 11/15/2018 Seametrics Internal and Confidential
8
Moving the Magnetic Pointer
11/15/2018 Moving the Magnetic Pointer Remove meter top and lens. Take care not to lose the sealing rings! Mouse-over & click play to see again. Seametrics Internal and Confidential
9
Moving the Magnetic Pointer
11/15/2018 Moving the Magnetic Pointer With your fingers, lift the magnetic pointer off its shaft and remove the plain pointer from the target dial. Mouse-over & click play to see again. Seametrics Internal and Confidential
10
Moving the Magnetic Pointer
11/15/2018 Moving the Magnetic Pointer Reverse their positions and press them firmly into place. Mouse-over & click play to see again. Seametrics Internal and Confidential
11
Moving the Magnetic Pointer
11/15/2018 Moving the Magnetic Pointer Carefully replace the sealing ring and the lens. Note: Match the tab on the lens to the notch on the meter to align the sensor with the magnetic pointer dial. Mouse-over & click play to see again. Seametrics Internal and Confidential
12
Moving the Magnetic Pointer
11/15/2018 Moving the Magnetic Pointer Thread the meter top on and tighten. Replace Security Wire Mouse-over & click play to see again. Seametrics Internal and Confidential
13
Moving the Magnetic Pointer
11/15/2018 Moving the Magnetic Pointer Note: A special magnet (available from the factory) is required to achieve a rate of 4 pulses per gallon. It should be placed on the x0.1 dial with non-magnetic pointers on remaining dials. Otherwise follow same procedures. 4 Pulse Magnet Seametrics Internal and Confidential
14