Pradnya Bapat 01/09/2017 Cummins Confidential
2
Background For CPS(s/w phase 31), the current bootloader(BL) version in ECMs does not support connected calibration(CC) feature The plan is to update BL only for customers who are interested in getting the CC feature Hence we need the bootloader information to be read by telematics devices in order to assess CC feature capability. Cummins Confidential
3
Change Request Currently SPN 234 is read by the Telematics devices from ECMs for registration. It includes - ECM Part Number ECM Serial Number Calibration Date Stamp Calibration Version ECM Identifier Product ID Request to add Bootloader version information at the end of the list as a delimited field. Cummins Confidential
4
Appendix: Cummins Confidential
5
Request for modification PGN information
PGN Software Identification Bytes Data Sent Number of software ID fields 1 byte 7 ECM Part Number 8 bytes See Note 1 Asterisk (*) 1 byte * ECM Serial Number 8 bytes See Note 1 Software Data Date Stamp 12 bytes See Note 1 Calibration Version Number 8 bytes See Note 1 ECM Identifier 2 bytes See Note 2 Examples: TS (CM870), DH (CM850) Asterisk (*) 1 byte * Product ID 3 bytes See Note 1 Asterisk (*) 1 byte * Bootloader Information 8 bytes See Note 1 Note 1: ASCII values identified by Cummins at time of manufacture. Note 2: Please see individual Serial Communications Applications Document Tech Packages Cummins Confidential