1
Sieder, Chapter 11 Terry Ring University of Utah
Heat Integration Sieder, Chapter 11 Terry Ring University of Utah
2
Lost Work = Lost Money Transfer Heat from T1 to T2
ΔT [= T1-T2] approach Temp. for Heat Exchanger To= Temperature of Environment Use 1st and 2nd laws of Thermodynamics ΔT LW=QTo(T1-T2)/(T1T2) Q= UoAΔTlm =UoA(ΔT1-ΔT2)/ln(ΔT1/ΔT2) T1 Q T2
3
Simple Heat Exchange Network (HEN)
Use another stream for HX instead of a utility. What happens when delta T in Exchanger is lowered? To Zero?
4
Costs Heat Exchanger Purchase Cost (Inside BL) Annual Cost
Cp,i=K(Areai)0.6 Area= Q/UoΔTlm Annual Cost CA=im[ΣCp,i+ ΣCP,A,j]+sFs+(cw)Fcw im=return on investment Fs= Annual Flow of Steam, $13.2/Tonne to $17.6/Tonne = s Fcw=Annual Flow of Cold Water $0.027/m3 = cw Auxiliary HX outside BL CpA is HX in auxiliary networks
5
Capital and Operating Cost Optimization
Capital cost goes down when A is less. This is caused by delta T being larger for Q to remain the same.
6
Heat Integration Make list of HX
Instead of using utilities can you use another stream to heat/cool any streams? How much of this can you do without causing operational problems? Can you use air to cool? Air is a low cost coolant. Less utilities = smaller cost of operations
7
Ultra-high purity Si plant design
Si at 99.97% Powder H2 & HCl Separation Train Fluid Bed Reactor ( C) Si+7HCl SiHCl3 + SiCl4 +3H2 Si+ 2HCl SiH2Cl2 Flash HCl H2-HCl Separation SiCl4 HCl H2 SiCl4 Very Pure SiHCl3&SiH2Cl2 Fluid Bed Reactor(600C) Si+SiCl4+2HCl 2SiHCl3 Flash Reactor (1200C) SiHCl3+H2 Si+3HCl SiH2Cl2+1/2 H2 Si+3HCl Si H2 HCl Si at %
10
Terms HEN=Heat Exchanger Network MER=Maximum Energy Recovery
Minimum Number of Heat Exchangers Threshold Approach Temperature Optimum Approach Temperature
11
Process
12
Minimize Utilities For 4 Streams
470 480
13
Simple HEN
14
Minimize Utilities For 4 Streams
470 480
15
Pinch Analysis 1) Adjust Hot Stream Temperatures to Give ΔTmin=10°F
Put T’s in order Max to Min 2) Order T’s, 250, 240, 235, 180, 150, 120
16
Enthalpy Differences for Temperature Intervals
17
Interval Heat Loads
19
Pinch Analysis 1) Adjust Hot Stream Temperatures to Give ΔTmin
Put T’s in order Max to Min Order T’s, 250, 240, 235, 180, 150, 120
20
Pinch Analysis Minimum Utilities
=ΔHi+50 Pinch Analysis Minimum Utilities R’s = residulas
21
Pinch Analysis Minimum Utilities
=ΔHi+50 Pinch Analysis Minimum Utilities R’s = residulas
23
Pinch Analysis Actual Endpoint Temperatures! ΔTapp MER values
24
Process
25
How to combine hot with cold?
Big Exhangers 1st 1st HX at Pinch (temp touching pinch) Above Pinch Connect Cc≥Ch Below Pinch Connect Ch≥Cc 2nd Hx or not touching Pinch temp. No requirement for Cc or Ch
26
Pinch Analysis Actual Endpoint Temperatures! Cc≥Ch ΔTapp MER values
3*( )=210 1.5*( )=90 2*( )=110 4*( )=240 ΔTapp MER values
27
Pinch Analysis Actual Endpoint Temperatures! Cc≥Ch ΔTapp MER values
3*( )=210 1.5*( )=90 2*( )=110 90=2*(T-180) T=225 4*( )=240 210=4*(T-180) T=232.5°F ΔTapp 20 30 MER values
28
How to combine hot with cold?
Big Exhangers 1st 1st HX at Pinch (temp touching pinch) Above Pinch Connect Cc≥Ch Below Pinch Connect Ch≥Cc 2nd Hx or not touching Pinch temp. No requirement for Cc or Ch
29
Pinch Analysis Actual Endpoint Temperatures! Ch≥Cc ΔTapp MER values
3*( )=90 1.5*( )=90 30=1.5*(190-T) T=170°F 2*( )=120 90=2*(180-T) T=135°F 2*( )=30 60 ΔTapp MER values
30
4 Heat Exchanger HEN for Min. Utilities
Cc≥Ch Ch≥Cc CW MER Values Steam
31
Pinch Analysis Minimum Utilities
=ΔHi+50 Pinch Analysis Minimum Utilities R’s = residulas
32
Minimum Utilities HEN
33
Simple HEN
34
Comparison Simple HEN HEN with Min. Utilities Saves CW 7.5e4 BTU/hr
Steam 7.5e4 BTU/hr
35
Too Many Heat Exchangers
Sometimes fewer Heat exchangers and increased utilities leads to a lower annual cost NHx,min= Ns + NU - NNW s=No. streams U=No. discrete Utilities NW=No. independent Networks (1 above the pinch, 1 below the pinch) Solution to Too Many Heat Exchangers Break Heat Exchanger Loops Stream Splitting Attack small Heat Exchangers First 4+2-2=4
36
Break Heat Exchanger Loops
37
Stream Splitting Two streams created from one
1 Two streams created from one one heat exchanger on each split of stream with couplings 1 1b 1a 1b 1a
38
Example CP=K(Area)0.6
39
Last Considerations How will HEN behave during startup?
How will HEN behave during shutdown? Does HEN lead to unstable plant operation?
41
Optimization of HEN How does approach ΔT >ΔTmin effect the total cost of HEN? Q= UA ΔT Less capital cost LW=QToΔT/(T1T2) More Utility cost
42
ΔTmin ΔTapp=10C ΔTapp=105C LW=QToΔT/(T1T2) S T(C) T(C) C Q(kW)
H H C ΔTapp=10C ΔTapp=105C LW=QToΔT/(T1T2)
43
Costs Heat Exchanger Purchase Cost (Inside BL) Annual Cost
Cp,i=K(Areai)0.6 Area= Q/UoΔTlm Annual Cost CA=im[ΣCp,i+ ΣCP,A,j]+sFs+(cw)Fcw im=return on investment Fs= Annual Flow of Steam, $13.2/Tonne to $17.6/Tonne = s Fcw=Annual Flow of Cold Water $0.027/m3 = cw Auxiliary HX outside BL CpA is HX in auxiliary networks
44
Change ΔTmin CP=K(Area)0.6 Area=Q/(UF ΔTmin) LW=QToΔT/(T1T2)
More Lost Work ΔT =UA/Q Utilities increase due to Lost work since it increases as ΔT increases LW=QToΔT/(T1T2)
45
Capital and Operating Cost Optimization
Capital cost goes down when A is less. This is caused by delta T being larger for Q to remain the same. ΔTthres
46
Distillation Columns
47
Heuristic “Position a Distillation Column Between Composite Heating and Cooling Curves”
48
Heat Integration for Direct Distillation Sequence
49
Multi-effect Distillation Adjust Pressure in C2 for ΔTmin
50
Heat Pumps in Distillation
51
Heat Pumps How do they work?
Carnot Efficiency ηmax= 1-Tc/Th Endoreversible η =1-√(Tc/Th) Same as Air Conditioner Convert low temperature heat to high temperature heat. Must add work as heat can not go up hill.
52
Heat Pumps/Heat Engines Heurisitcs
When positioning heat engines, to reduce the cold utilities, place them entirely above or below the pinch When positioning heat pumps, to reduce the total utilities, place them across the pinch.
53
Heat Pumps Where can they be used?
Heuristic When positioning heat pumps, to reduce the total utilities, place them across the pinch.
54
Heat Engines Where can they be used?
Tp Heuristic When positioning heat engines, to reduce the cold utilities, place them entirely above or below the pinch