Korea Transportation Safety Authority 1 정 혁 책임연구원 Korea Automobile Testing and Research Institute(KATRI) 200 Samjon-Ro, Songsan-Myun, Hwasung-Si, Gyeonggi-Do, 18247 Water immersion test EVS GTR IWG #15 March Bohyun Moon / Chief Researcher
2
Water immersion test Flooded Cars in Korea annually
More than 1% of all flooding accidents in Korea occur in seawater.
3
Immerse into 0.6M(3.5% NaCl) salt water for 1hr
Water immersion test Date of entry into force : Feb. 2009 Purpose Evaluation of traction battery safety under Vehicle immersion accident Test Procedure Criteria Immersion Immerse into 0.6M(3.5% NaCl) salt water for 1hr No Fire & No Explosion
4
Water immersion test Statistical analysis of Water immersion test
- Water immersion test has been conducted 46 times since 2011 - 6 EV batteries and 1 HEV battery failed EV HEV Other Total Pass Fail 2 46 22 6 15 1 28 16
5
Water immersion test DUT Specification of Failed Water immersion test
DUT of test 1 and 2 were same battery. Test 2 was just retest for the test 1 was conducted properly. Because the test 1 was first failure we experienced. Test 3’s battery was LTO cells. The videos of test 4, 5, 6 will play. Vehicle V Ah kWh Event Remark 1 BUS 607.5 80 48.6 Fire 2 " Retest of #1 DUT 3 Bus 607.2 40 24.3 LTO cells 4 706.5 120 84.8 Non-Insulated Case 5 625.6 94 58.8 DUT floated 6 Truck 110.1 364.8 40.2 18650 cells 7 HEV 307.2 10 3.1 Explosion LFP cells / IPX7
6
Water immersion test DUT Specification of Failed Water immersion test
Test 4’s enclosure was stainless steel and its inside was non insulated. Test 5 : Due to a lack of ventilation for the gas, Buoyancy increased and the pack floated. Test 6’s battery consist of over 5,000 cylinder cells. Test 7 was water proof battery with LFP cells. The waterproofing broke during the test and exploded. Cause of Defect DUT inside was insufficient distance through insulation (DTI) or insufficient insulation Passed after improved insulation and extended distance through insulation (DTI) Vehicle V Ah kWh Event Remark 4 Bus 706.5 120 84.8 Fire Non-Insulated Case 5 625.6 94 58.8 DUT floated 6 Truck 110.1 364.8 40.2 18650 cells 7 HEV 307.2 10 3.1 Explosion LFP cells / IPX7
7
Comparison before and after improvement
Water immersion test Test #4 Video Cause of Defect The inside of stainless steel enclosure was not insulated so a path was generated and an event occurred when immersed. Passed the test after insulating the case inside. Comparison before and after improvement
8
Buoyancy increased and pack floated
Water immersion test Test #5 Video Cause of Defect Due to a lack of ventilation for the gas, Buoyancy increased and the pack floated. Passed the test by making additional ventilation holes and improved insulation. Buoyancy increased and pack floated
9
Relatively low voltage & high current battery
Water immersion test Test #6 Video Cause of Defect The voltage of this battery was not high compared to other batteries, but the DUT was sealed as much as possible to slow the entry of water. The waterproofing broke during the test and exploded. Passed the test after modified that can be completely immersed. Relatively low voltage & high current battery
10
Water immersion test Summary
The cause of the event was insufficient insulation and insufficient distance through insulation (DTI) of inside the DUT. It is estimated that an event occurs when the above condition is not satisfied, as well as the magnitude of the voltage and it’s current. Future work Water immersion tests will be conducted with differences in salinity from fresh water to salt water increasing in amount from test to test.
11
Thank you for attention!