Download presentation
1
Coriolis Technology
2
Coriolis Technology This explanation of Coriolis technology answers the following questions: What is a Coriolis meter? How does it work? Why use it?
3
Coriolis Technology This explanation of Coriolis technology answers the following questions: What is a Coriolis meter? How does it work? Why use a Coriolis meter?
4
What is a Coriolis meter?
A Coriolis meter is a multi-variable measurement device. It provides for the indication of: Mass Density Volume
5
What is a Coriolis meter?
Sensor Electronics Peripheral device MICRO MOTION
6
What is a Coriolis meter?
Sensor Housing
7
What is a Coriolis meter?
Flow tubes
8
What is a Coriolis meter?
Flow splitter (Manifold)
9
What is a Coriolis meter?
Drive coil assembly
10
What is a Coriolis meter?
Left pick-off coil assembly Right pick-off coil assembly
11
What is a Coriolis meter?
3-wire platinum RTD
12
Coriolis Technology This explanation of Coriolis technology answers the following questions: What is a Coriolis meter? How does it work? Why use a Coriolis meter?
13
How does it work? Drive coil causes tubes to vibrate at natural frequency. Electronics provide energy to drive coil, accept signals from pick-off coils, and output values for mass, volume, density, and temperature. MICRO MOTION Pick-off coils generate sign waves used to indicate position of tubes to each other.
14
How does it work? NO FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off
Left Pick-Off Drive mV Hz No Phase Shift
15
How does it work? NO FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off
Left Pick-Off Drive mV Hz No Phase Shift
16
How does it work? NO FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off
Left Pick-Off Drive mV Hz No Phase Shift
17
How does it work? NO FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off
Left Pick-Off Drive mV Hz No Phase Shift
18
How does it work? NO FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off
Left Pick-Off Drive mV Hz No Phase Shift
19
How does it work? NO FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off
Left Pick-Off Drive mV Hz No Phase Shift
20
How does it work? NO FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off
Left Pick-Off Drive mV Hz No Phase Shift
21
How does it work? NO FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off
Left Pick-Off Drive mV Hz No Phase Shift
22
How does it work? FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off mV
Left Pick-Off Drive mV Hz Tme Lag
23
How does it work? FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off mV
Left Pick-Off Drive mV Hz Time Lag
24
How does it work? FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off mV
Left Pick-Off Drive mV Hz Time Lag Left Right
25
How does it work? FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off mV
Left Pick-Off Drive mV Hz Time Lag Left Right
26
How does it work? FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off mV
Left Pick-Off Drive mV Hz Time Lag Left Right
27
How does it work? FLOW SIDE VIEW FRONT VIEW TOP VIEW Right Pick-Off mV
mV Hz Time Lag Right Drive Left Left Pick-Off TOP VIEW
28
How does it work? FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off mV
Left Pick-Off Drive mV Hz Time Lag Left Right
29
How does it work? No FLOW SIDE VIEW TOP VIEW FRONT VIEW Right Pick-Off
Left Pick-Off Drive mV Hz No Phase Shift Left Right
30
How does it work? Factory Calibration
31
How does it work? % of full scale flow Four Point Calibration % Error
25% 50% 100% Repeated % Error Four Point Calibration % of full scale flow
32
How does it work? Time mV High Density Low Density Coil Magnet
33
How does it work? Mass and density are measured. Volume is calculated.
Volume (gal/min) = Mass rate (lb/min) Density (lb/gal)
34
Coriolis Technology This explanation of Coriolis technology answers the following questions: What is a Coriolis meter? How does it work? Why use a Coriolis meter?
35
Why use a Coriolis meter?
Multi-Variable Measurement Mass, Density, and Volume Non-Intrusive - reduced maintenance No moving parts - no mechanical parts to wear Measures fluids laden with solids (ie sand) Not damaged by slugs of air Simple, Compact Installation No straight pipe runs required Accuracy High turndown ratio Reduced drift in accuracy due to wear
36
Why use a Coriolis meter?
Simple, compact installation. Crude oil gathering station Two 3-inch and one 2-inch ELITE meters flowing into larger pipeline
37
Why use a Coriolis meter?
Simple, compact installation. 3-inch ELITE meter in pipeline custody transfer of crude oil in suburban location Replaced troublesome PD meter
38
Why use a Coriolis meter?
Simple, compact installation.
39
Why use a Coriolis meter?
Simple, compact installation. 3-inch ELITE meter used to measure crude from tanks
40
Why use a Coriolis meter?
Simple, compact installation. Slipstream installation - density measurement Strainer is source of slipstream pressure differential for flow through Flow rate through Coriolis sensor can indicate the basket’s need for cleaning
41
Why use a Coriolis meter?
Multi-Variable Measurement Mass, Density, and Volume Non-Intrusive - reduced maintenance No moving parts - no mechanical parts to wear Measures slurries Not damaged by slugs of air Simple, Compact Installation No straight pipe runs required Accuracy High turndown ratio Reduced drift in accuracy due to wear