Building Safety and Accommodation Requirements u Compliance with safety and health standards under the Buildings Ordinance u Enlisting the service of Authorized Persons u Formal submission of plans for approval u AP/RSE Directory (www.info.gov.hk/bd) u Viewing approved plans/documents u Land use and lease matters
4
Structural Design (1) u 2.0 kPa for dormitory areas u 2.5 kPa for living/recreational areas u RSEs structural justification for increased load such as raised screed and partition wall u Sound structural condition
5
Structural Design (2) u Additional solid wall
6
Structural Design (3) u Raised screed
7
Fire Resisting Construction (1) u Compliance with FRC Code
8
Fire Resisting Construction (2) Some general requirements: u 1 hour FRP compartmentation u 1 hour FRP wall and 1/2 hour FRP door for kitchen u AP/RSEs substantiation on fire resisting components
9
Fire Resisting Construction (3)
10
Means of Escape (1) u Compliance with MOE Code 1996
11
Means of Escape (2) Some general requirements: u Discharge value u MOE provision in any particular floor u Clear width exit door u One 750mm exit door for rooms <30 persons u Two exit doors (850mm each, total 1750mm) for rooms between 31-200 persons; lines of direct distance >30 o; open in the direction of exit; not obstructing other exit route
12
Means of Escape (3) XXXXXX
13
Means of Escape (4)
14
Means of Escape (5) u 2m headroom for exit routes u maximum 18m deadend u 30m to 45m (depending on the fire resisting construction) to staircase u 450mm solid separation from other accommodation at the discharge point of exit staircase
15
Means of Escape (6)
16
Means of Escape (7) u Occupancy factor = 3 m 2 usable floor area/person u Fire engineering approach
17
Lighting and Ventilation (1) u Habitable room (2.5m under floor slab, 2.3m under beam) u Windows of habitable rooms, offices and kitchens facing external air (glass area, openable area) u Windows of rooms containing sanitary fitments facing open air (glass area and openable area)
18
Lighting and Ventilation (2) u Artificial lighting and mechanical ventilation (>5 air changes/hour) to the satisfaction of the BA u Adequate aperture for room-sealed gas water heater serving bathrooms
19
Sanitary Fitments u 1-8 residents : 1 WC, 1 basin, 1 bath/shower u 9-20 residents : 2 WCs, 2 basins, 2 baths/showers u Every additional 15 residents or part thereof, 1 additional WC, basin and bath/shower
20
Unauthorized Building Works u similar to other types of licensed premises