Download presentation
Presentation is loading. Please wait.
Published byKatarina Folwell Modified over 10 years ago
1
O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY 1 Transitioning to Version 8 Building Data Entry Issues in NEAT/MHEA and Oak Ridge National Laboratory Weatherization Assistant Training Workshop
2
2 The Weatherization Assistant Umbrella program for NEAT and MHEA Version 7.4.3 (released August 12, 2003) Version 8.6.0.4 (released November 9, 2009) Purpose Identify for experienced users technical and implementation changes made to NEAT and MHEA in Version 8 As time permits, highlight common data entry mistakes in using NEAT and MHEA pertinent to Versions 7 and 8 B UILDINGS T ECHNOLOGY C ENTER OAK RIDGE NATIONAL LABORAORY
3
3 Transition Elements
4
4 Main Menu Screen - Version 7
5
5 Main Menu Screen - Version 8 Client information is entered separately from NEAT and MHEA house and file information
6
Agency Information - Version 7 6
7
Agency Information - Version 8 7
8
Agency Contacts - Version 8 8
9
9 General Information Tab - NEAT/MHEA Version 7 Typically started NEAT or MHEA by entering client, house, and file information on the General Information tab
10
10 Main Menu Screen - Version 8 Client information is entered separately from NEAT and MHEA house and file information Separate client main menu item
11
11 Version 8 Client Main Menu Item Client information is entered before starting NEAT or MHEA
12
12 Version 8 Client Contacts Tab Client Name is entered under separate Contacts tab under the Client Main Menu Item. More than one Contact can exist for a given Client record.
13
13 Version 8 Audit Information Tab - NEAT/MHEA House and file information is entered on the Audit Information tab after starting NEAT or MHEA Must now also link to Fuel Cost and Supply Libraries
14
14 Navigation - NEAT/MHEA Version 7 Version 8 New tabs for Version 8s advanced features Audit record block to find files / Report block Shell forms organized under one Shell tab
15
NEAT CHANGES 15
16
16 Wall Tab – NEAT - Version 7 Windows and doors pertinent to the wall code are shown on the wall form
17
17 Wall Tab – NEAT – Version 8 Windows and doors pertinent to the wall code are accessed by buttons Comment button - links to comment editor
18
18 Windows Tab – NEAT – Version 7 Retrofit Status renamed Retrofit Options. Replace with Low-E and Evaluate None added Field replaced with Additional Cost fields for all retrofit options
19
19 Windows Tab – NEAT – Version 8 Added Retrofit Options and replaced Storm Cost by Additional Cost fields for each option Added yet un-used description fields
20
20 Doors Tab – NEAT - Version 8 Clarified wording - optional and pertinent to door rather than storm door
21
21 Version 8 Unfinished Attics Tab - NEAT Added R Value field allows specific insulation level to be analyzed (and no others)
22
22 Finished Attics - NEAT Version 7Version 8 Version 8 allows for multiple finished attics segments of the same type
23
23 Foundations – NEAT - Version 8 Reformatted form separates component types
24
24 Foundations Tab - NEAT Use Added Insulation Type fields to indicate what insulation measures are to be evaluated. Have added User-Defined Insulation Types.
25
25 Heating Systems – NEAT - Version 8 Buttons access diagnostic input forms Multiple heating systems allowed rather than just two - dont need to heat 100% Standard and high efficiency replacement equipment can be specified simultaneously
26
26 Heating Systems – NEAT – Version 8
27
27 Heating System Tab - NEAT Optional [Evaluate All] - Allows NEAT to determine most cost-effective option, if any Tuneup Performed Tells NEAT to determine the most cost-effective of the remaining options, if any Efficiency entered for existing system is the value after the tuneup Tuneup Mandatory, Standard- and High- Efficiency Replacement Mandatory, Forces NEAT to recommend measure without considering other options even if not cost effective Dont Replace-Tells NEAT to not consider the two replacement options Evaluate None – Evaluates no heating system options
28
28 Heating Systems – NEAT - Version 8 Better ability to describe ducts for duct insulation measure
29
29 Heating Tab – NEAT - Version 8 Secondary system can be combined with primary when considering replacement
30
CHANGES IN BOTH NEAT AND MHEA 30
31
31 Diagnostic Input Forms - NEAT/MHEA Operational TestsVent Tests
32
32 Diagnostic Input Forms - NEAT/MHEA Furnace ComponentsBoiler Components
33
33 Diagnostic Input Forms - NEAT/MHEA InspectionsVent Tests
34
34 Version 8 Health and Safety Tab - NEAT/MHEA Red box highlights health and safety items identified Checked items can be automatically entered as an Itemized Cost New tab
35
35 Version 8 Health and Safety Tab - NEAT/MHEA
36
36 Version 8 Health and Safety Tab - NEAT/MHEA
37
37 Version 8 Itemized Costs Tab - NEAT/MHEA Description now Measure Name Fuel can now be chosen to be the same as the Primary Heating or Water Heating Fuel
38
38 Version 8 Itemized Costs Tab - NEAT/MHEA Predefined measures can be selected. For example:
39
39 Version 8 Itemized Costs Tab - NEAT/MHEA Or select from list of 50 hard-wired Health and Safety Measures. For example:
40
40 Version 8 Refrigerator Tab - NEAT/MHEA New fields added, calculations shown, and two data bases accessed
41
MHEA CHANGES 41
42
42 Windows Tab – MHEA - Version 8 Leakiness field added Retrofit options with Additional cost fields for each option added Added yet un-used description field
43
43 Floor Tab – MHEA - Version 8 Attached to Joist selection replaced with Between Joists and Attached Under Joists Batt/Blanket Direction field removed
44
44 Version 8 Floor Tab - MHEA Attached Under JoistsBetween Joists
45
45 Version 8 Floor Tab (Addition) - MHEA In Version 7, floors of additions described as if they were a mobile home type floor In Version 8, Floor Type field added to describe more traditional floor types
Similar presentations
© 2025 SlidePlayer.com. Inc.