Outlet Branch Circuit Arc Fault Circuit Interrupter (OBC AFCI)

Similar presentations


Presentation on theme: "Outlet Branch Circuit Arc Fault Circuit Interrupter (OBC AFCI)"— Presentation transcript:

1 Outlet Branch Circuit Arc Fault Circuit Interrupter (OBC AFCI)

2 AFCI Receptacles – Codes, Products, Usage Guide
How it works. Guidelines on usage in existing circuits. What products are available NEMA generated white paper: Guide to Prevention of Arcing Ignited Fires in Homes See next slide for embedded presentation

3 What’s going on? U.S. Fire Administration (USFA) reported in 2011, an estimated ,700 home structure fires reported to fire departments involved some type of electrical failure or malfunction as factor in fire’s ignition Resulted in 418 civilian deaths 1,570 civilian injuries $1.4 billion in direct property damage According to the National Fire Protection Association (NFPA), arc-faults are one of “the principle electrical failure mode resulting in fire”.

4 Danger of Electrical Faults
13% home fires in the U.S. were electrical in origin 50% of those electrical fires resulted from arcing *National Fire Protection Association (NFPA) Annually, an estimated 28,300 residential building electrical fires cause 360 deaths, 1,000 injuries, and $995 million in direct loss *Topical Fire Report Series, Volume 8, Issue 2 / March 2008, U.S. Fire Administration 15% of residential building electrical fires start in bedrooms 47% of residential building electrical fires where equipment was involved were caused by wiring Electrical fire data is most likely underreported

5 What is an “arc fault”? When electric current unintentionally “arcs” outside of the conductor without proper insulation Concentrated temperatures from the exposed current can exceed ,000 degrees Fahrenheit and ignite surrounding material Arc faults can be low level in terms of current BUT high level of heat and therefore, difficult for conventional overcurrent devices to detect Two general types of arc faults: Series Arc “In-line fault”- Break or gap in a single conductor connecting a load where a “jump” occurs in the line Parallel Arc Arc fault that occurs Line-to-Ground or Line-to-Neutral

6 Parallel vs. Series Arcing
Line-to-neutral OR Line-to-ground Series In-Line

7 Possible Causes of Dangerous Arc Faults
Wire Degradation Natural degradation through age Humidity or heat Extended mechanical stress Extended voltage stress Physical Damage Animals chewing through insulation Nails, tacks from construction or picture hanging driven into a wall through a wire(s) Extension or power supply cord damage from sharp bends, furniture on or against cords, sharp bends General cord damage Poor wiring or connection at devices/j-boxes

8 What is an AFCI? AFCI detects arc faults (an unintentional arcing condition in a circuit) that standard circuit breakers and receptacles (GFCI’s, etc.) are not designed to detect Intended to mitigate the effects of arc faults by functioning to de-energize the circuit when an arc fault is detected AFCI detects both types of arc faults: Parallel (Line-to-neutral or Line-to-ground) Series (In-line) arcing AFCI’s reduce chances of electrical system BECOMING an ignition source Smoke alarms, fire extinguishers, and escape ladders are emergency equipment used to take action AFTER fire occurs

9 How AFCI’s Work Detection done by use of advanced electronic technology Monitors circuit for presence of “normal” and “dangerous” arcing conditions

10 Outlet Branch Circuit vs. Combination AFCI

11 AFCI vs. GFCI AFCI Provides protection from electrical fires that could result from arcing faults Works by detecting potentially hazardous arc fault and quickly cutting off power GFCI Protects users from shocks and electrocution at point of use Works by cutting off power quickly enough to prevent harm

12 AFCI & GFCI Location Requirements
Family Room Dining Room Living Room Kitchen Laundry Room Parlor Library Dens Bedrooms Sunroom Rec Room Closets Hallways Similar Areas GFCI: Bathrooms Garage Porch Laundry Room 

13 Overlapping Applications with GFCI’s
Kitchen GFCIs- Countertops, islands, and within 6-ft of sinks AFCIs- All other outlets Laundry Rooms GFCIs- Within 6-ft of sinks There are NO compatibility issues or concerns using AFCIs and GFCIs on the same circuit! Devices that include both types of protection are being introduced

14 National Electrical Code® on Arcing
2014 NEC New Branch Circuits: Section (A) Modifications/Extensions: Section (B) – Combination-type AFCI at the origin of the branch circuit or OBC AFCI at the first receptacle outlet Replacement Receptacles: Section 406.4(D)(4) – Replacement receptacles must be either OBC AFCI Receptacle, or protected by Combination-type AFCI breaker or OBC AFCI receptacle

15 New Branch Circuits - 210.12 (A)

16 New Branch Circuits: Section 210.12(A)

17 Modifications/Extensions to Existing Branch Circuits - 210.12 (B)

18 Receptacle Replacements - 406.4(D)(4)

19 Summary of AFCI Requirements by NEC*
New Circuits Where a new circuit is being run from a circuit breaker panel or sub-panel Applies to all types of circuits – receptacles, lighting, and smoke detectors If using an OBC AFCI, it must be installed at the first outlet AFCI circuit breaker is also acceptable Modifications and Extensions to Branch Circuits Includes adding additional receptacles or outlets on an existing branch circuit or moving existing outlets Typically occurs during renovations to specific spaces or room additions Applies to all outlets - receptacles, lighting and smoke detectors * See slide 16 for details