1 Robert Graf | CEO Mobile

2 About ProLion CEO, Robert Graf Headquarter in Austria
ProLion invented ClusterLion (automatic switchover for MC) NetApp Alliance Partner, NetApp Certified Solution Product distribution: ABO, Arrow, ALEF, ICOS, INGRAM, TIM We are focused on NetApp

3 Our Portfolio

4 High Availability in IT
High availability is a MUST in today’s IT world! This applies across industries Mission-critical applications must be available at all time! “Always ON” is a prerequisite for many companies! Downtime costs money and image!

5 Cost of Downtime The cost by industry and studies vary, but it is clear that IT downtime causes considerable damage!

6 Split-Brain Syndrome Wikipedia: Split-brain indicates data or availability inconsistencies originating from the maintenance of two separate data sets with overlap in scope, either because of servers in a network design, or a failure condition based on servers not communicating and synchronizing their data to each other. High-availability clusters usually use a heartbeat private network connection which is used to monitor the health and status of each node in the cluster. For example the split-brain syndrome may occur when all of the private links go down simultaneously, but the cluster nodes are still running, each one believing they are the only one running.

7 The challenge of every Storage Cluster
Every storage vendor on the market needs a quorum, witness or tie-breaker to run automatic switchover in case of site-failure! Expensive infrastructure investments in a 3rd data center location and highly redundant interconnects form the primary data centers to the quorum site are required! With ClusterLion no infrastructure investment is needed, which offers the lowest possible TCO for automatic switchover. ClusterLion is only available for NetApp MetroCluster.

8 ONTAP 8.3 MetroCluster DR Guide
Source:

9 ONTAP 9.x MetroCluster DR Guide
Source:

10 Sixt

11 SRV1 SRV2 SRV2 Ethernet Srvc(a) Srvc(b) MC Fabric Grid UPS Grid UPS

12 ClusterLion Q A2 A1 B2 B1 SRV1 SRV2 “Switchback”
Customer Support during Giveback Switchover Ethernet / SAN 2x RS232 2x Ethernet 2x RS232 2x Ethernet Srvc(a) Srvc(a) Srvc(b) Srvc(b) MC Fabric A2 A1 B2 B1 100m Grid UPS 100m Grid UPS Telco B Telco A Q Remote Quorum Use Case: Power Outage 1. Reporting: A2: Active Controller Heartbeat A1: Lost Cluster Partner, NVRAM etc. B2: No Controller Heartbeat B1: Controller Error 2. Action: B2: Power Off B1: Power Off A2: Active Controller Heartbeat A1: Force Switchover Q: Open Helpdesk Ticket Monitoring: Power Supply Storage Controller Partner Status Heart-Beat Open Ticket Partner Helpdesk

13 Q Network Switchover Switchover SRV1 SRV2 Ethernet VLAN VLAN MC Fabric
Ping Ping Ethernet VLAN VLAN Ping Ping Srvc(a) Srvc(b) MC Fabric 100m Grid UPS 100m Grid UPS Telco B Telco A Q Remote Quorum

14 Application Integration
Switchover SRV1 SRV2 APP Ethernet Srvc(a) Srvc(b) MC Fabric 100m Grid UPS 100m Grid UPS Telco B Telco A Q Remote Quorum

15 Q IP-MetroCluster no AUSO!!! 40Gbit 4-Node MetroCluster
SRV1 SRV2 Ethernet Srvc(a) Srvc(a) Srvc(b) Srvc(b) MC Fabric no AUSO!!! 100m Grid UPS 100m Grid UPS Telco B Telco A Q Remote Quorum 40Gbit 4-Node MetroCluster High-End Storage Controller (FAS9000, A700, A700s)

16 Solutions for MetroCluster Switchover
Manual Switchover Tie-Breaker ClusterLion Support for 7-Mode and cDOT MC config. Continuesoperation after site-failure X Only two data centers needed to run automatic switchover Highly secure against Split-Brain and data loss Independet remote view on MetroCluster Very easy to install and operate (Patch mgmt, etc.) Switchover in case of network failure Application integrated switchover

17 ClusterLion Hardware (I)
ClusterLion without Front Cover „Hot Swap“ Battery

18 ClusterLion Hardware (II)
4x Power Input Reset Button 4x Power Output 2x Serial Consol Port Cooling Fan 4x Ethernet Connectivity PoE Output for Gateways Fuse

19 ClusterLion Premium Support
Premium support contract: 24x7 telephone support Proactive customer notification ProLion support during MetroCluster switchback 3rd Party maintenance partners in EMEA

20 Customer Benefits ClusterLion increases the availability of your NetApp MetroCluster. Even in the event of site failures alle MetroCluser services will be properly delivered and applications remain available. ClusterLion works with only two datacentre locations. This reduces costs and complexity. A third site (Quorum) will be provided by ProLion. ClusterLion prevents data corruption in case of Split Brain syndrome. ClusterLion permanantly ensures a consistent state in the storage cluster. ClusterLion can be retrofitted to any existing storage cluster without downtime

21 What‘s next…

22 The question is not if you can afford ClusterLion!
The question is if you can afford to run operation without ClusterLion? The question is not if you can afford ClusterLion!

23 Thank you! ClusterLion Robert Graf | CEO Mobile +43 664 1314403