Dry Canyon Study Design Hydrographs
2
TL=52 min. GA Params for Loam
This uses streamstats average slope of 53%
3
Design Study 6 hour Hydrograph
From Anderson Consulting Dry Canyon Design, 2006
4
TL=87 min. GA Params for Loam
This uses longest flow path length slope of 19% that results in longer lag time
5
TL=52 min. K=2.1 in/hr (smallest in soil tests)
Note significantly smaller discharge volume and peak
6
TL=52 min. CN=63. 12 Hr freq storm
7
TL=87 min. GA Params for Loamy Sand
8
Detention basin geometry
The sides A, B, C, and D are sloped 1:2, 1:2, 1:5, and 1:1, respectively
9
Result with 3 ft orifice
10
Result with 5 ft Orifice
11
Actual design study model
12
Actual design study hydrograph
13
Effect of impervious areas
Overall 10% area mapped as impervious Precip = 2.37 in Vol = acre ft Vol from pervious 44.9 acre ft =58.5 Hydrograph without impervious area Conclusion: Precise quantification of the losses is critically important for this design and a source of significant uncertainty