1 WELCOME Indoor Chillers

2 TRANE SOLUTIONS EQUIPMENT SYSTEM CONTROLS SERVICES PARTS TRAINING
MANUFACTURING

3 Indoor chillers applications
INTRODUCTION Indoor chillers applications Typical applications: Existing buildings Retrofit / replacement of existing units New buildings Sound sensitive environments Typical associated constraints: Handling of the unit to the plant room Space required for the unit Space required for auxiliary equipment (pumps, expansion tank, etc) Replacement of cooling tower with dry cooler or remote condenser Desire to limit or improve building HVAC energy consumption

4 INTRODUCTION Trane, the world-wide leader in HVAC solutions, making your life easier... Indoor chillers

5 Designed with your needs in mind
INTRODUCTION Designed with your needs in mind Specially designed for: Higher performance Higher flexibility Easier installation Superior reliability Optimized serviceability

6 345 kW PERFORMANCE Wide capacity coverage Capacity coverage
180 to 345 kW Versions available CGWN Packaged water-cooled unit CCUN Condenserless (for application with air - cooled remote condenser) With or without hydraulic module on: Chilled water loop Heat rejection loop 180 kW 210 kW 235 kW 260 kW 290 kW 320 kW 345 kW

7 A concentrate of technology
PERFORMANCE A concentrate of technology Scroll Compressors Fewer moving parts: 64 % fewer than reciprocating compressors Optimized oil distribution Decreased pressure losses Higher volumetric efficiencies State of the art control Intelligent control components connected to a communication BUS Limited wiring = Increased reliability Connectable service tools Lon protocol compatible LCD Touch Screen Navigation by file tabs Chiller tab Compressor tab Refrigerant tab Set point tab Diagnostic tab Auto/Stop Plate heat exchangers with imbricated circuits More stable leaving water temperature Better part load operation Less risk of freeze-up at part load

8 + 20% PERFORMANCE High efficiency Efficiency through design
Designed to meet the most stringent energy efficiency criteria in: Comfort cooling Process applications 2 versions are available : SE = Standard Efficiency HE = High Efficiency COP: 4.6 COP: 3.85 Reciprocating Chillers AquaStream²® Indoor Chillers

9 PERFORMANCE Optimized operation Efficiency optimization
Pump Absorbed kW Efficiency optimization CH530 control designed to minimize the energy consumption in any configuration: Example, hydraulic kit on heat rejection loop: Limits number of pumps in operation at part load SAVINGS 50 % 100 % % Unit load

10 Limited impact on environment
PERFORMANCE Limited impact on environment Ozone Layer protection HFC R407C refrigerant ODP = 0 Global warming Direct impact Low GWP Limited refrigerant charge due to circuit design Indirect impact High efficiency Controls Energy consumption

11 Condensing leaving water 60°C Chilled leaving water -12°C
FLEXIBILITY Wide operating range Condensing leaving water 60°C Operation flexibility As standard, wide range of temperature applications range, including the most severe: Low evaporator temperature: Process cooling Food & beverage industry Ice storage applications High condensing temperature: Dry cooler or remote condenser with high ambient conditions Heat reclaim applications Chilled leaving water -12°C

12 Heat sink Cold sink FLEXIBILITY Heat reclaim applications
Hot water control applications Aquastream² Indoor Chillers usable for applications where it is necessary to elevate temperature level: Heating Energy recovery Capacity modulated to match the heating demand: Condenser water leaving temperature is the primarily factor taken into account, Evaporator leaving water temperature is monitored only to ensure freeze-up protection. Heat sink Cold sink

13 Integrated pump package
FLEXIBILITY Integrated pump package Single loop configuration Operation flexibility Multiple choice of pump packages available as standard to cover all type of hydraulic configurations: Single loop configuration Decoupled system Load 2 Load 1 Decoupled system configuration Load 2 Load 1

14 FLEXIBILITY Split system version CCUN Condenserless chiller
Specifically designed for applications with a remote condenser. Benefits: No cooling tower required Easier maintenance Low sound outside of the building Remote condenser Indoor chiller (CCUN)

15 FLEXIBILITY System integration Compatibility Factory-mounted controls
Interoperability Compatibility Factory-mounted controls LonTalk® open communication protocol Capability of communicating with any Building Management System. Management Level Operator Interface Web Server Tracer SummitTM LCD Touch Screen Building Controls BCU Field Server Automation Level Site Installed Unit Controls MP581 INTEGRATION MP501/MP503 EX2 Field Devices Control, Measure, Monitoring Field Level Power panel control Lighting control Energy metering Alarm control and monitoring 3rd party equipment control Building information monitoring HVAC Equipment With Factory- Mounted Controls

16 Conventional technology
RELIABILITY Designed for the most severe conditions State of the art control Logic enables corrective actions to keep chiller safely on-line making cold water where other chillers would trip off. Example, in case of problem on cooling tower on a very hot day, controls automatically: Finds the balance point Continues to deliver maximum amount of chilled water without tripping off Displays an alarm message of auto-limitation Conventional technology

17 More parameters monitored
RELIABILITY More parameters monitored State of the art control Control functions Control & operation optimisation: Chilled water temperature control Control of either condenser pump or remote condenser fans Operating mode control: Compressor start/stop logic Load and unload logic of the compressors Low ambient start logic Fast load adjustment Start with warm water Safety functions: Welded contacts Water flow Antifreeze Reverse rotation Phase unbalance

18 2600 mm 880 mm EASE OF INSTALLATION Limited required footprint
Compact Design Facilitates the integration inside the building Makes maximum use of the space available in the machine room : Unit can fit through a single door Hydraulic components fit inside the same volume 2600 mm 880 mm

19 Condensing and chilled water piping Rubber pads (supplied)
EASE OF INSTALLATION Limited installation time Electrical installation Single power connection : Control transformer supplied factory wired Hydraulic connection Integrated hydraulic module : On request, the unit can be supplied with all necessary components required on the hydraulic side: Evaporator Condenser Condensing and chilled water piping Power supply Rubber pads (supplied)

20 Ambient temp. or Return water temp.
EASE OF INSTALLATION Several possibilities of remote monitoring Comm5 External water temperature setpoint Unit emergency Stop External demand limit setpoint Ice making Unit On/Off switch External temperature setpoint reset Auxiliary setpoint Cooling/Heating switch Water setpoint Compressor running Latching alarm Chiller limit mode Ambient temp. or Return water temp. Warning

21 Maximum dependability
MAINTENANCE Maximum dependability Easy maintenance All major components accessible from 3 sides Easily cleanable water filters only one connection to open Maintenance of the refrigeration circuit limited to 1 yearly oil analysis

22 SUMMARY Proven and reliable technology
Years of chilled water production guaranteed High energy efficiency, environmental friendly Full respect of environmental criteria Lower operating cost Reduced refrigerant charge State of the art control More accurate temperature, Energy optimisation Easy integration in upper system control Optimum application flexibility Easier to select Easier to install Easier to operate Easier to maintain

23 THANK YOU Indoor Chillers