SURGICAL DIATHERMY
2
DIATHERMY: Used during cutting and coagulation of the tissues
Consists of high frequency power oscillators Spark gap oscillators Undamped current: clean cutting Damped current: coagulation
3
Electro surgical unit:
4
Requirement: High temperature exceeding 1000 degree C
1 mm diameter of cross section of arc High current density Frequency : 250 Hz to 1 MHz Cutting : 400 W Coagulation : 150 W (10-15 s & 15 KHz)
5
Block diagram: Control panel & logic board: produces the basic signal and timing informations Operates the relays, give visual indications and determine the alarm conditions Isolated and carefully insulated Avoid contact to conducting surfaces.
6
Automated electro-surgical systems:
Size and shape of cutting electrode Type and speed of cut Tissue properties Voltage control or spark control Programmed processors decides the spark intensity
7
Contd. Soft coagulation: no electric arcs, prevents skin from carbonized Forced coagulation: arcs are intentionally generated between the coagulation electrode and the tissue (deeper coagulation) Spray coagulation: arcs are deliberately produced. Contact is not necessary
8
Electro surgery techniques:
Mono polar technique: depends on the contact area Bi polar technique : two electrodes. Contact area is less. Safer and precise.
9
Electrodes used: Needle electrode: desiccation
lancet electrode: cutting Loop electrode : ecsecting (opening) the channels, extirpating growth Performance: improper placement of electrode Loss of energy ( Mono phasic electrode)
10
LASER Physiotherapy and electrotherapy equipments
Heat radiation by the application of high frequency radiation (through heating) Muscles, bones, internal organs etc. Polarity of the electric field alters, continuous re-alignment of the molecules Microwaves and ultrasonic waves are used for heating purpose
11
Short wave diathermy: Hot towels, infrared lamps, electric heating pads Heat is produced within the body rather not transferred through the skin (to avoid discomfort and skin burns) Can be controlled precisely AC frequency : MHz ( no muscle contraction)
12
Circuit diathermy and automatic tuning:
Page no: 762 Anode voltage: 4000 V Controlling the anode voltage, filament heating current Adjusting the grid leak resistance, R1.
13
Application technique:
Capacitor plate method: Tissues are kept sandwiched between the two pads No direct contact Also called as Condenser method
14
Contd. Inductive method: The cable is coiled around the arm
RF current is passed and the magnetic field applies the heat (electro static action) Also called as inductohermy
15
Diapulse therapy: Increase in energy output avoids the dangers of heat
Pulse width : 65 micro second Interval : 1600 micro second
16
Micro wave diathermy: Frequency : 300 to 30,000 MHz (2450 MHz)
Wavelength : 10 mm to 1 m (12.25 cm)
17
Contd. Delay circuit Magnetron circuit Safety circuit
18
Ultrasonic therapy unit:
Absorption property of the tissues Piezo electric effect
19
Contd. Controlling the firing angle Frequency of ultrasound
Intensity of ultrasound Duration of exposure Avoids injury
20
Apparatus: Galvanic current: Steady flow of current 10-20 minutes
21
Contd. Exponentially progressive current: Independent pulse duration
22
Contd. Faradic current: Sequence of pulses
With defined shape and current 80 mA of magnitude 25 surges per minute
23
Functional diagram:
24
Contd. Distortion free Irrespective of patient’s resistance
Position of the electrodes should be rigid Mono-polar electrode : indifferent electrode is placed near to the active electrode.
25
Transcutaneous electrical nerve stimulator:
Gate control theory: prevents pain carrying messages Endorsphin release theory: stimulation of pain killing substance (Endorsphin)
26
Spinal cord stimulator:
Not for patients using triggered or inhibited type of pacemakers
27
Magnetic stimulator: Electrical stimulator is very painful
Magnetic pulse is generated by passing a brief, high-current pulse through a coil of wire Still experimental
28
Diaphragm pacing by radio frequency for the treatment of chronic ventilatory insufficency:
Only one phrenic nerve could affect normal oxygen and carbon-di-oxide exchange
29
Contd. Bladder stimulators: Reflex actions can be controlled
Possible kidney malfunction Cerebellar stimulators: Inhibiting intractable epilepsy