1 Analytical & Bioanalytical Techniques
Joshua Hicks Catalent Pharma Solutions September 2, 2015

2 NMR quantification vs. other methods
For automated, internal-standard-free, absolute quantization… NMR is accurate, precise and versatile Superior to CLND ELSD Weighing CLND ELSD Analytical Chemistry (2005), 77(14),

3 Quantificaiton with Internal Standard (IS)
X mg of Compound X mg of IS Purity of IS Concentration of Compound? Purity of Compound?

4 Using PULCON & 10 mM Concentration of Unknown
J Am Chem Soc Mar 1;128(8): Reference Standard for PULCON NMR of Sample Calibrated to a sample of known concentration, known number of protons 10 mM & P1 Calibration NS TE Integrals # Protons Concentration of Unknown

5 Accuracy of Analysis? Considerations for Reducing Error in Quantification Sample Prep Parameter Set Field Strength (less error at higher fields) Probe Instrument stability Method of integration (Region or Linefit) Room stability SOPs Calibrant Region (pure) Linefit (overlap)

6 Automation (Acquisition and Analysis)
A Tale of Two Probes Single sample, same instrument – does configuration matter? Error Automation (Acquisition and Analysis) Manual Analysis Reference Std PULCON (region) LINEFIT ‘Unknown’ Region 400MHz BBO 8% 4-5% 2-3% 0.7% 400MHz QNP 2% <1% <0.2% <0.1%

7 Quantification of Compounds in Crude Extract
* * * * 32.8mM

8 Youden Ruggedness’ Trial
600 MHz vs. 400 MHz Different gravimetric balance Different days NMR Tube Quality Different pulse sequence Different concentration Mesh Size (Also EtOH:Leaf) Chlorogenic Acid BBE Delta ~ 2% 600 400 7

9 Benefits of High Quality Data: L-Carvone
Red = double presat Blue = Wetdc Water DMSO L-Carvone 100 Hz

10 QC/QA System Non-NMR user Simple interface Lockdown Automated
Suitability test Acqu/Proc Identification Quantification Report

11 Towards Automatic Analysis
Quantification Proton, fluorine, and phosphorus Identification of residual solvents Assist with identification of ‘unknown’ signals System: PDF report Concentration verification (based on spectra and submitted compound) Verification by either: Proton only Or proton+carbon Or proton+hsqc Stop light evaluation of atom assignment

12 discover more. CATALENT PHARMA SOLUTIONS 14 SCHOOLHOUSE ROAD SOMERSET, NJ 08873