Download presentation
Presentation is loading. Please wait.
1
Scintillator HCal R&D Update
Vishnu V. Zutshi for NIU/NICADD
2
V. Zutshi,ALCPG04,Victoria
Introduction Snapshot of past results Photo-detector characterization X-talk Reflectors Summary 11/23/2018 V. Zutshi,ALCPG04,Victoria
3
V. Zutshi,ALCPG04,Victoria
Digital HCal with Scintillator Density based PFA Snapshot of past results I Needs validation in test beam 11/23/2018 V. Zutshi,ALCPG04,Victoria
4
Stack & Tile Fabrication
~15pe/mip Snapshot of past results II 11/23/2018 V. Zutshi,ALCPG04,Victoria
5
Tile-Fiber-Reflector Optimization
Snapshot of past results III 11/23/2018 V. Zutshi,ALCPG04,Victoria
6
V. Zutshi,ALCPG04,Victoria
Relative LY cast Snapshot of past results IV extruded 11/23/2018 V. Zutshi,ALCPG04,Victoria
7
V. Zutshi,ALCPG04,Victoria
SiPM/MRS ~1000 pixels on 1mm x 1mm Bias voltage ~ 50-60V Gain ~ 106 Quantum x geom ~ 12-15% 11/23/2018 V. Zutshi,ALCPG04,Victoria
8
V. Zutshi,ALCPG04,Victoria
Count Rate vs. Bias Green LED(~130Hz) with clear fiber used 11/23/2018 V. Zutshi,ALCPG04,Victoria
9
Noise Amplitude vs. Bias
11/23/2018 V. Zutshi,ALCPG04,Victoria
10
Signal Amplitude vs. Bias
11/23/2018 V. Zutshi,ALCPG04,Victoria
11
SiPM Signal & Pedestal examples
42.5V 43.5V 11/23/2018 V. Zutshi,ALCPG04,Victoria
12
MRS Signal & Pedestal examples
50.5V 52.0V 11/23/2018 V. Zutshi,ALCPG04,Victoria
13
V. Zutshi,ALCPG04,Victoria
S/N vs. Bias 11/23/2018 V. Zutshi,ALCPG04,Victoria
14
V. Zutshi,ALCPG04,Victoria
Dark Rate 11/23/2018 V. Zutshi,ALCPG04,Victoria
15
Temperature dependence
-3%/oC 11/23/2018 V. Zutshi,ALCPG04,Victoria
16
Photo-detector Irradiation
Detectors sent to Michigan gamma irradiation facility Dosage ~ 1MRad Comparison of noise and signal detection before and after irradiation Plan to irradiate with protons 11/23/2018 V. Zutshi,ALCPG04,Victoria
17
MRS before/after irradiation I
11/23/2018 V. Zutshi,ALCPG04,Victoria
18
MRS before/after irradiation II
11/23/2018 V. Zutshi,ALCPG04,Victoria
19
MRS before/after irradiation III
11/23/2018 V. Zutshi,ALCPG04,Victoria
20
V. Zutshi,ALCPG04,Victoria
Photo-Detector Scan Clear fiber Oscilloscope Amplifier Photodetector LED Driver LED In collaboration with P. Polozov & G. Sellberg 11/23/2018 V. Zutshi,ALCPG04,Victoria
21
V. Zutshi,ALCPG04,Victoria
Scan Results I 11/23/2018 V. Zutshi,ALCPG04,Victoria
22
V. Zutshi,ALCPG04,Victoria
Scan Results II a 11/23/2018 V. Zutshi,ALCPG04,Victoria
23
V. Zutshi,ALCPG04,Victoria
0.3% per side X-talk (wrapped) 2.56 uA 90Sr PMT + mixer 2.49 uA 2.72% Crosstalk + Spillover PMT + mixer 90Sr 0.04 uA 1.56% Spillover 90Sr PMT + mixer 11/23/2018 V. Zutshi,ALCPG04,Victoria
24
V. Zutshi,ALCPG04,Victoria
X-talk (mated) 1.3% per side 11/23/2018 V. Zutshi,ALCPG04,Victoria
25
Reflector Performance
11/23/2018 V. Zutshi,ALCPG04,Victoria
26
Uniformity and Reflectors
11/23/2018 V. Zutshi,ALCPG04,Victoria
27
V. Zutshi,ALCPG04,Victoria
Summary Good progress on scintillator-based digital hadron calorimetry R&D studies has been made(2 papers accepted for publication). Focus has shifted now to construction and commissioning issues for the test beam prototype where all this can finally be put to the test. 11/23/2018 V. Zutshi,ALCPG04,Victoria
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.