1 KaVo SONICflex bone tips in use with INTRAsurg 1000 Air
SONICflex bone – Indications and settings KaVo SONICflex bone tips in use with INTRAsurg 1000 Air Indications and settings © KaVo Dental GmbH

2 Comparison of cutting power
SONICflex bone – Indications and settings Comparison of cutting power (standardized oscillating cuts made under 50g working pressure) From left to right: Round rotary drill SONICflex bone sagittal saw Competitor 1/oscillation Competitor 2/oscillation © KaVo Dental GmbH

3 Important recommendations for use
SONICflex bone – Indications and settings Important recommendations for use Make sure of incoming air pressure level between bar (technical adjustement), otherwise required power will not be reached. Don‘t press SONICflex bone tips against bone – minimization of power. Correct working pressure can be compared with writing by sharpened pencil. Choose the right power setting on regulation ring of SONICflex 2003 L according to user instructions of each single tip (see instructional manual). © KaVo Dental GmbH

4 Tip no. 80, square Sonicflex 2003L setting: Level 3 Indications:
SONICflex bone – Indications and settings Tip no. 80, square Sonicflex 2003L setting: Level 3 Indications: Dividing Sharpey`s fibres Extension of alveolar bone for: Removal of root sections Gentle extraction prior to implantation Separation of multi-rooted teeth Bonesplitting Dr. F. Heinemann, Morsbach © KaVo Dental GmbH

5 Tip no. 81, diamond-coated sphere
SONICflex bone – Indications and settings Tip no. 81, diamond-coated sphere SONICflex 2003L setting: Level 3 Indications: Bone window preparation for sinuslift In case of massive bone structure cortical bone could be cut by rotary method and only remaining bone structure is being removed by oscillating method. Dr. Dr. S.-H.Gnoth, Köln © KaVo Dental GmbH

6 Tip no. 82, non-diamond-coated sphere
SONICflex bone – Indications and settings Tip no. 82, non-diamond-coated sphere SONICflex 2003L setting: Level 2 or 3 Indication: Separation of Schneider‘s membrane during sinuslift Dr. Dr. S.-H.Gnoth, Köln © KaVo Dental GmbH

7 Oscillating saws Tips no. 83 (axial)/84 (sagittal)
SONICflex bone – Indications and settings Oscillating saws Tips no. 83 (axial)/84 (sagittal) SONICflex 2003L settings: Level 3 Indications: Removal of bone blocks, Osteotomy (Distraction, Bonesplitting) In case of massive bone structure cortical bone could be cut by rotary method and only remaining bone structure is being removed by oscillating method 84 sagittal 83 axial(quer) Dr. E.Guez, Paris Dr. E. Guez, Paris © KaVo Dental GmbH