Presentation is loading. Please wait.

Presentation is loading. Please wait.

Rapid Emergency Methods for Actinides and Sr-89/90

Similar presentations


Presentation on theme: "Rapid Emergency Methods for Actinides and Sr-89/90"— Presentation transcript:

1 Rapid Emergency Methods for Actinides and Sr-89/90
Sherrod L. Maxwell, III Westinghouse Savannah River Company

2 Background Radiological Preparedness Exercise (NRIP’04)
Kenneth Inn, NIST spoke at RRMC-2004 of “need to improve efficiency and effectiveness of radioanalytical capabilities” Need for faster actinide and Sr-89/90 analyses for Homeland Security reasons Current water/air filter methods may take 1-2 days Need for fast, reliable methods (< 8 hours)

3 Developments at SRS Water/Air Filters Method
Streamline calcium phosphate precipitation (water) Dissolve air filters Collect and prepare Sr-89/90 with actinides No ashing of Am/Cm or Th fractions Eichrom prefilter cartridges/Resolve filters

4 Developments at SRS Streamline calcium phosphate precipitation
Eliminate heat step for volumes less than 200 mL/add Ba to complex carbonate Use 200 mL (or less) sample volumes in centrifuge tubes Prep time: ~1-1.5 hours-12 samples Stack TEVA (Pu, Np, Th) + TRU (Am,Cm, U) + Sr Resin (Sr-89/90) Collect Sr-89/90 at same time Prep time: <4 hours-12 samples Count time actinides-1 hour (or as needed) Sr-89/90-10 minutes (or as needed)

5 Rapid TEVA-TRU-Sr Separations (Pu, Np, Am, Cm, U, Sr)

6 Remove Sr on Sr Resin, Pu from TEVA and Am-Cm/U from TRU

7 Am Strip with Prefilters Below TRU

8 Performance 20 groundwater samples 200 mL volume/ 6 hour counts *
Sr carrier recoveries: 98.1% (3.9% rsd) Pu-242 recoveries: 104% (4.9% rsd) Am-243 recoveries: 92.6% (6% rsd) U-232 recoveries: % (5.4% rsd) *count less time in emergency when high levels expected

9 Other Efficiency Improvements
Eliminate ashing steps used for extractant bleed-off that affects alpha resolution Prefilter cartridge(~$5) with Resolve filters Saves time, labor, better FWHM faster TAT improved alpha resolution less rework

10 Resolution with Filters from “Bad” Lot

11

12

13

14 Summary Need to share radioanalytical methods-Ken Inn
Faster actinide and Sr-89/90 methods developed Quality and Speed Streamlined precipitation for water samples Collect Pu, Am, Cm, U, Sr in a single stacked column High recoveries, good resolution, no interferences Applicable to radiological emergency analyses Improved efficiency and effectiveness Short count as needed Analysis time < 8 hours


Download ppt "Rapid Emergency Methods for Actinides and Sr-89/90"

Similar presentations


Ads by Google