Presentation is loading. Please wait.

Presentation is loading. Please wait.

MDL0L02 Dipole Hysteresis Loop Study

Similar presentations


Presentation on theme: "MDL0L02 Dipole Hysteresis Loop Study"— Presentation transcript:

1 MDL0L02 Dipole Hysteresis Loop Study
September 20, 2016

2 CEBAF DL Magnet at Injector

3 Field Map (27 G-cm Offset Subtracted)

4 Field Map Residuals (Bdl-p1*I)

5 Hysteresis Loop

6 Modified Hysteresis Loop
Two Modifications: Subtract 8 G-cm from I=0 Bdl Subtract A from Magnet Current

7 Final New Field Map Modifications:
Current (A) Strength (Gauss-cm) 0 91 Modifications: Subtract environmental field offset of 27 G-cm Subtract 8 G-cm from I=0 Bdl Subtract A offset from Magnet Current

8 Spare DL Magnet at MMF

9 Field Map (49 G-cm Offset Subtracted)

10 Field Map Residuals (Bdl-p1*I)

11 Hysteresis Loop

12 Modified Hysteresis Loop
One Modifications: Add A offset to Magnet Current

13 Summary Hysteresis loop study of CEBAF DL magnet showed:
Bdl abnormality at I=0. Fixed by subtracting 8 G-cm. Magnet current during mapping was off by A. Fixed by subtracting this offset from map current . Similar check for the spare DL, showed a current offset Request to install new Field Map for CEBAF DL magnet