MDL0L02 Dipole Hysteresis Loop Study
September 20, 2016
2
CEBAF DL Magnet at Injector
3
Field Map (27 G-cm Offset Subtracted)
4
Field Map Residuals (Bdl-p1*I)
5
Hysteresis Loop
6
Modified Hysteresis Loop
Two Modifications: Subtract 8 G-cm from I=0 Bdl Subtract A from Magnet Current
7
Final New Field Map Modifications:
Current (A) Strength (Gauss-cm) 0 91 Modifications: Subtract environmental field offset of 27 G-cm Subtract 8 G-cm from I=0 Bdl Subtract A offset from Magnet Current
8
Spare DL Magnet at MMF
9
Field Map (49 G-cm Offset Subtracted)
10
Field Map Residuals (Bdl-p1*I)
11
Hysteresis Loop
12
Modified Hysteresis Loop
One Modifications: Add A offset to Magnet Current
13
Summary Hysteresis loop study of CEBAF DL magnet showed:
Bdl abnormality at I=0. Fixed by subtracting 8 G-cm. Magnet current during mapping was off by A. Fixed by subtracting this offset from map current . Similar check for the spare DL, showed a current offset Request to install new Field Map for CEBAF DL magnet