Contherm Mitre Series CAT CO2 Cell Culture Incubators

Similar presentations


Presentation on theme: "Contherm Mitre Series CAT CO2 Cell Culture Incubators"— Presentation transcript:

1 Contherm Mitre Series CAT 4150 - 4400 CO2 Cell Culture Incubators
The Contherm Mitre Series offers the user precise performance,user friendly operation and long term dependability. The Mitre series of culture incubators is available in three sizes from 150L to 400L. Additionally, the cabinets can be configured to have either Peltier (‘T’ suffix) or conventional cooling(‘C’ suffix) fitted to operate at temperatures as low as +15oC. Thermal Conductivity CO2 sensor with humidity and temperature compensation. CAT 4150 Contherm Scientific Ltd

2 Contherm Mitre Series Range of sizes from 150L to 400L
FEATURES Range of sizes from 150L to 400L Stainless steel interior, powder coated exterior Crevice-free interior for easy cleaning Heated glass inner door to minimise condensation Microprocessor PID controller LED displays for Temperature, CO2 and Humidity Thermal conductivity CO2 sensor User adjustable overtemperature cutout The Mitre series incubators use the following sensors: Thermal Conductivity (for measurement of CO2 concentration) Silicon Temperature sensor Capacitive Humidity Sensor When CO2 in injected into the closed chamber, the conductivity of the air is lowered, the thermal conductivity system measures this change and uses it to calculate the concentration of CO2 in the chamber. Contherm Scientific Ltd

3 Contherm Mitre Series SPECIFICATIONS Contherm Scientific Ltd

4 Contherm Mitre Series CONTROL PANEL Large readable LED displays
Status LEDs. Set Point Mode LEDs Easy Touch ‘Tactile’ buttons Temperature calibration may be performed via the front panel buttons. By entering a special calibration mode the display may be adjusted to register the same value as a certified thermometer, the resulting ‘CAL FACTOR’ will be shown and should be recorded for future reference. The CO2 sensor may be put into an AUTO-CAL mode where the CO2 solenoid is inhibited and the CO2 display ‘Flashes’ until a suitable baseline has been found for the thermal conductivity sensors. When the baseline is stable the display will cease to ‘Flash’ and the solenoid will be alloed to bring the CO2 concentration up to the desired level. The capacitive humidity sensor is factory precalibrated and requires no further adjustment to give a typical accuracy of +- 5% RH. Temperature CO2/%RH CO2/Down TEMP/Up Status Contherm Scientific Ltd

5 Contherm Mitre Series CALIBRATION
Temperature Calibration via front panel buttons. Temperature Cal Factor Available. Auto-CO2 Calibration with manual override. Relative Humidity Pre-calibrated. Temperature calibration may be performed via the front panel buttons. By entering a special calibration mode the display may be adjusted to register the same value as a certified thermometer, the resulting ‘CAL FACTOR’ will be shown and should be recorded for future reference. The CO2 sensor may be put into an AUTO-CAL mode where the CO2 solenoid is inhibited and the CO2 display ‘Flashes’ until a suitable baseline has been found for the thermal conductivity sensors. When the baseline is stable the display will cease to ‘Flash’ and the solenoid will be alloed to bring the CO2 concentration up to the desired level. The capacitive humidity sensor is factory precalibrated and requires no further adjustment to give a typical accuracy of +- 5% RH. Contherm Scientific Ltd

6 Contherm Mitre Series PERFORMANCE
CO2 concentration between 0.3% and 19.9% CO2. Temperature control within +- 37oC Relative Humidity levels above 90% Rapid recovery after a door opening Contherm Scientific Ltd

7 Contherm Mitre Series AIR CIRCULATION One-pass fan circulation
Fully sealed glass door. Unique catch & hinge May be fitted with a HEPA filter on the circulating fan inlet as a special option. Cutaway illustration of a Mitre Series CO2 Incubator Contherm Scientific Ltd

8 Contherm Mitre Series RECOVERY Contherm Scientific Ltd
Repeated opening of the chamber door is a problem in any busy laboratory, leading to unacceptable conditions which adversly affect cell growth. The graphs shown compare the recovery of Contherm Mitre Series incubators with a typical water-jacketed incubator after a 30second door opening. Contherm Scientific Ltd

9 Contherm Website: http://www.contherm.com E-Mail: contherm@xtra.co.nz
SCIENTIFIC LTD HOW TO CONTACT US Contherm Website: Mail: Contherm Scientific Ltd P O Box Lower Hutt New Zealand Fax: Phone: Contherm Scientific Ltd