1 Smitty’s Two Minute Drill #1: Feeders and Branch Circuits
A drill to help you improve your code skills and your ability to find answers in the code book. © Ted “Smitty” Smith 2016, 2017

2 Directions Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. Each slide will transition to the correct answer automatically in 2:00 minutes. The correct answer will transition in 5 seconds. Do not worry about writing down the correct answer for now. You will have the opportunity to do that at the end of the two minute drill Good luck

3 Question 1 An outlet installed for the purpose charging electric vehicles shall be supplied by a ________________ branch circuit. This circuit shall have no other outlets. A. Listed B. Separate C. Multi-wire D. None of the above Copyright 2005 Ted "Smitty" Smith

4 Question 1 Answer B. Separate 210.17 Copyright 2005 Ted "Smitty" Smith

5 Question 2 Overhead conductors for festoon lighting shall not be small than ______ AWG unless the conductors are supported by messenger wires. A. 16 B. 14 C. 12 D. 10 Copyright 2005 Ted "Smitty" Smith

6 Question 2 Answer C. 12 225.6 (B) Copyright 2005 Ted "Smitty" Smith

7 Question 3 Tire inflation and automotive vacuum machines provided for public use shall be protected by a ____________________. A. Listed over current device rated at 125% of the full load current B. arc-fault circuit interrupter C. Duel element fuse rated at 80% of the full load current D. ground-fault circuit interupter Copyright 2005 Ted "Smitty" Smith

8 Question 3 answer D. Ground-fault circuit interupter 422.23
Copyright 2005 Ted "Smitty" Smith

9 Question 4 Loads for new circuits or extended circuits in other than dwelling units shall be calculated with ______________, as applicable. A. a #2 pencil and paper B. A scientific programmable calculator C. either or D. a derating factor of 75% or 80% Copyright 2005 Ted "Smitty" Smith

10 Question 4 Answer C. 220.12 or 220.14 220.16(B)
Copyright 2005 Ted "Smitty" Smith

11 Question 5 Branch circuits shall not be derived from autotransformers unless the circuit supplied has a grounded conductor that is ______________________ ___________________ _____ a grounded conductor of the system supplying the transformer. Sized larger than Noncontiguous electrically to Electrically connected to Separated completely from Copyright 2005 Ted "Smitty" Smith

12 Question 5 C. electrically connected to 210.9
Copyright 2005 Ted "Smitty" Smith

13 Question 6 What is the minimum height that the auxiliary equipment of electric discharge lamps can be mounted on poles for athletic fields if the voltage rating for the equipment is 600 volts? 10 feet 18 feet 22 feet 30 feet Copyright 2005 Ted "Smitty" Smith

14 Question 6 answer C. 22 feet 210.6(D)(1)(a)
Copyright 2005 Ted "Smitty" Smith

15 Question 7 High voltage conductors in tunnels shall be installed in metal conduit, other metal raceway or type _____________ cable. A. AC B. NM C. SO D. MC Copyright 2005 Ted "Smitty" Smith

16 Question 7 answer D. MC 110.53 Copyright 2005 Ted "Smitty" Smith

17 Question 8 Outdoor mobile home disconnecting means shall be installed so the bottom of the enclose containing the disconnecting means is not less than _________ above the finished grade or working platform. A. 2 feet B. 6 feet, 7 inches C. 10 feet D. 12 feet Copyright 2005 Ted "Smitty" Smith

18 Question 8 answer A 2 feet 550.32(F) Copyright 2005 Ted "Smitty" Smith

19 Question 9 Where the positive polarity of a dc system does not serve as the connection point for the grounded conductor, each positive ungrounded conductor shall be identified by:[ Select the answer that is incorrect.] A. a continuous red outer finish B. a continuous red stripe durably marked along the conductors entire length on insulation of a color other than green, white, gray or black C. a continuous red stripe durably marked marked along the conductors entire length on insulation of a color other green, white, or gray. D. imprinted plus signs (+) or the word POSITIVE or POS durably marked on insulation of a color other than green, white, gray or black. Copyright 2005 Ted "Smitty" Smith

20 Question 9 answer C. a continuous red stripe durably marked marked along the conductors entire length on insulation of a color other green, white, or gray. Missing that it can not be black wire 210.5(C) (2) (a) (1-3) Copyright 2005 Ted "Smitty" Smith

21 Question 10 Where connected to a branch circuit supplying two or more receptacles, a 20 ampere rated branch circuit shall be allowed to supply ______________ rated receptacles. A. 15 ampere receptacles B. 20 ampere receptacles C. Both A and B D. Neither A or B Copyright 2005 Ted "Smitty" Smith

22 Question 10 Answer C. Both A and C 210. 21 (B)(3)
Copyright 2005 Ted "Smitty" Smith

23 Question 11 The minimum feeder conductor size shall have an allowable ampacity not less than the maximum load to be served after the application of _________________________. A. any adjustment or correction factors. B. temperature derating adjustments in accordance with C. conduit fill derating corrections based on Table 5 D. continuous duty rating of loads based on Copyright 2005 Ted "Smitty" Smith

24 Question 11 Answer A. any adjustment or correction factors.
215.2(A)(1)(b) Copyright 2005 Ted "Smitty" Smith

25 Question 12 Vegetation such as trees may be used for support of overhead conductor spans if the attachment point is at least 8 feet above the ground and secured with a device listed for the purpose. A. True B. False Copyright 2005 Ted "Smitty" Smith

26 Question 12 Answer B. False 225.6 Copyright 2005 Ted "Smitty" Smith

27 Question 13 The grounded conductor for a service feeder shall not be smaller than the minimum size as required by ___________________. The authority having jurisdiction 250.24(C) The electrical engineer None of the above Copyright 2005 Ted "Smitty" Smith

28 Question 13 answer 250.24(C) 230.42(C)
Copyright 2005 Ted "Smitty" Smith

29 Question 14 The equipment branch of the Essential Electrical System of a health care facility shall be installed and connected to the alternate power source such that the equipment is automatically restored to operation at ________________. A. no more than 10 seconds from loss of power B. no more than 30 seconds from loss of power C. no more than 2 minutes from loss of power D. at appropriate time-lag intervals following the energizing of the essential electrical system. Copyright 2005 Ted "Smitty" Smith

30 Question 14 answer D. at appropriate time-lag intervals following the energizing of the essential electrical system. 517.34 Copyright 2005 Ted "Smitty" Smith

31 Question 15 At least one receptacle shall be installed at each peninsular countertop space with a long dimension of 24 inches or greater and short dimension of __________ inches or greater. A. 6 B. 9 C. 12 D. 18 Copyright 2005 Ted "Smitty" Smith

32 Question 15 Answer C. 12 210.52(C)(3)
Copyright 2005 Ted "Smitty" Smith

33 End of Drill Click on this slide to continue to the repeat of the questions. The timer will not operate in this section. Click on each slide to advance. Review the questions and look up the answers. Copyright 2005 Ted "Smitty" Smith

34 Question 1 An outlet installed for the purpose charging electric vehicles shall be supplied by a ________________ branch circuit. This circuit shall have no other outlets. A. Listed B. Separate C. Multi-wire D. None of the above Copyright 2005 Ted "Smitty" Smith

35 Question 1 Answer B. Separate 210.17 Copyright 2005 Ted "Smitty" Smith

36 Question 2 Overhead conductors for festoon lighting shall not be small than ______ AWG unless the conductors are supported by messenger wires. A. 16 B. 14 C. 12 D. 10 Copyright 2005 Ted "Smitty" Smith

37 Question 2 Answer C. 12 225.6 (B) Copyright 2005 Ted "Smitty" Smith

38 Question 3 Tire inflation and automotive vacuum machines provided for public use shall be protected by a ____________________. A. Listed over current device rated at 125% of the full load current B. arc-fault circuit interrupter C. Duel element fuse rated at 80% of the full load current D. ground-fault circuit interupter Copyright 2005 Ted "Smitty" Smith

39 Question 3 answer D. Ground-fault circuit interupter 422.23
Copyright 2005 Ted "Smitty" Smith

40 Question 4 Loads for new circuits or extended circuits in other than dwelling units shall be calculated with ______________, as applicable. A. a #2 pencil and paper B. A scientific programmable calculator C. either or D. a derating factor of 75% or 80% Copyright 2005 Ted "Smitty" Smith

41 Question 4 Answer C. 220.12 or 220.14 220.16(B)
Copyright 2005 Ted "Smitty" Smith

42 Question 5 Branch circuits shall not be derived from autotransformers unless the circuit supplied has a grounded conductor that is ______________________ ___________________ _____ a grounded conductor of the system supplying the transformer. Sized larger than Noncontiguous electrically to Electrically connected to Separated completely from Copyright 2005 Ted "Smitty" Smith

43 Question 5 C. electrically connected to 210.9
Copyright 2005 Ted "Smitty" Smith

44 Question 6 What is the minimum height that the auxiliary equipment of electric discharge lamps can be mounted on poles for athletic fields if the voltage rating for the equipment is 600 volts? 10 feet 18 feet 22 feet 30 feet Copyright 2005 Ted "Smitty" Smith

45 Question 6 answer C. 22 feet 210.6(D)(1)(a)
Copyright 2005 Ted "Smitty" Smith

46 Question 7 High voltage conductors in tunnels shall be installed in metal conduit, other metal raceway or type _____________ cable. A. AC B. NM C. SO D. MC Copyright 2005 Ted "Smitty" Smith

47 Question 7 answer D. MC 110.53 Copyright 2005 Ted "Smitty" Smith

48 Question 8 Outdoor mobile home disconnecting means shall be installed so the bottom of the enclose containing the disconnecting means is not less than _________ above the finished grade or working platform. A. 2 feet B. 6 feet, 7 inches C. 10 feet D. 12 feet Copyright 2005 Ted "Smitty" Smith

49 Question 8 answer A 2 feet 550.32(F) Copyright 2005 Ted "Smitty" Smith

50 Question 9 Where the positive polarity of a dc system does not serve as the connection point for the grounded conductor, each positive ungrounded conductor shall be identified by:[ Select the answer that is incorrect.] A. a continuous red outer finish B. a continuous red stripe durably marked along the conductors entire length on insulation of a color other than green, white, gray or black C. a continuous red stripe durably marked marked along the conductors entire length on insulation of a color other green, white, or gray. D. imprinted plus signs (+) or the word POSITIVE or POS durably marked on insulation of a color other than green, white, gray or black. Copyright 2005 Ted "Smitty" Smith

51 Question 9 answer C. a continuous red stripe durably marked marked along the conductors entire length on insulation of a color other green, white, or gray. Missing that it can not be black wire 210.5(C) (2) (a) (1-3) Copyright 2005 Ted "Smitty" Smith

52 Question 10 Where connected to a branch circuit supplying two or more receptacles, a 20 ampere rated branch circuit shall be allowed to supply ______________ rated receptacles. A. 15 ampere receptacles B. 20 ampere receptacles C. Both A and B D. Neither A or B Copyright 2005 Ted "Smitty" Smith

53 Question 10 Answer C. Both A and C 210. 21 (B)(3)
Copyright 2005 Ted "Smitty" Smith

54 Question 11 The minimum feeder conductor size shall have an allowable ampacity not less than the maximum load to be served after the application of _________________________. A. any adjustment or correction factors. B. temperature derating adjustments in accordance with C. conduit fill derating corrections based on Table 5 D. continuous duty rating of loads based on Copyright 2005 Ted "Smitty" Smith

55 Question 11 Answer A. any adjustment or correction factors.
215.2(A)(1)(b) Copyright 2005 Ted "Smitty" Smith

56 Question 12 Vegetation such as trees may be used for support of overhead conductor spans if the attachment point is at least 8 feet above the ground and secured with a device listed for the purpose. A. True B. False Copyright 2005 Ted "Smitty" Smith

57 Question 12 Answer B. False 225.6 Copyright 2005 Ted "Smitty" Smith

58 Question 13 The grounded conductor for a service feeder shall not be smaller than the minimum size as required by ___________________. The authority having jurisdiction 250.24(C) The electrical engineer None of the above Copyright 2005 Ted "Smitty" Smith

59 Question 13 answer 250.24(C) 230.42(C)
Copyright 2005 Ted "Smitty" Smith

60 Question 14 The equipment branch of the Essential Electrical System of a health care facility shall be installed and connected to the alternate power source such that the equipment is automatically restored to operation at ________________. A. no more than 10 seconds from loss of power B. no more than 30 seconds from loss of power C. no more than 2 minutes from loss of power D. at appropriate time-lag intervals following the energizing of the essential electrical system. Copyright 2005 Ted "Smitty" Smith

61 Question 14 answer D. at appropriate time-lag intervals following the energizing of the essential electrical system. 517.34 Copyright 2005 Ted "Smitty" Smith

62 Question 15 At least one receptacle shall be installed at each peninsular countertop space with a long dimension of 24 inches or greater and short dimension of __________ inches or greater. A. 6 B. 9 C. 12 D. 18 Copyright 2005 Ted "Smitty" Smith