Status of Vertical Neutron Camera Integration

Similar presentations


Presentation on theme: "Status of Vertical Neutron Camera Integration"— Presentation transcript:

1 Status of Vertical Neutron Camera Integration
Albert Tsutskikh Anatoli Krasilnikov Yuri Kaschuck Denis Prosvirin SRC RF TRINITI 11 of April 2006

2 VNC Purposes Collimated measurements of neutron source profile with spatial resolution along ITER major radius Total neutron yield (fusion power) measurement Optimization of the schemes of additional heating, including ICRH in particular

3 VNC Plasma Coverage Collimator lengths 1,4 – 1,6 m Diameters 30 mm
Coverage from –0.7 to 0.7 ρ

4 Divertor Port #2 Arrangement Drawing
Blanket module #18 Divertor cassette Neutron collimator block Detectors modules

5 3D view

6 Removable Rail Part with collimator block

7 Added block part for diverter

8 Detector modules

9 MCNP – A General Monte Carlo N-Particle Transport Code
Program MCNP (Transport Methods Group Los Alamos National Laboratory) Version 4C Cross-section library “endf601” (Evaluated Nuclear Data File)

10 MCNP Model of ITER Coils Intercoil structure
Blanket module #18 with slot Collimator Block Diverter Cassette with block part

11 MCNP Model of ITER

12 MCNP Model of ITER

13 MCNP Model of VNC

14 Source spatial distribution
Model of Source Source spatial distribution En=14.1 MeV

15 Calculation results

16 Calculation results for U-238 FC, threshold – 1 MeV & NDD, threshold 7 MeV
Signal – flux of nonscattared neutrons, background – flux of scattered neutrons

17 Calculation results

18 New Problem #1 From L. Bertalot
Interface Divertor cassette – Rail (second part of collimator block)

19 New Problem #2 From L. Bertalot
Need to verify if complete assembly fits inside the cask

20 New Problem #3 From L. Bertalot Fixed to the Cassette Body

21 New Problem #4 From L. Bertalot Integrates the Locking Pins
Integrates the Rail

22 Conclusions Lengths of collimators are enough for effective VNC operation. Correction coefficient should be applied for channel #1 & #10. Integrated with divertor cassette Lower VNC is providing required collimation and plasma coverage for both (238U FC, NDD) discussing detectors. Interface issues (integration with divertor cassette, interface with removable rail part and blanket module) could be solved during further design activity.

23 MUST BE SOLVED Procedure of assembling and installations
Tools for installation Mechanical prelifting construction and other modification divertor cassette Alignment and calibration Mechanical details of rail Agreement of blanket module # 18 modification to provide VNC lines of site penetration Interfaces with other port diagnostics Cable connections and communications Analysis of tomography possibilities with discussing RNC and VNC lines of sight