1 Sensitivity tests of BLM_S chamber in PSB dump
(Detector for very high radiation areas of LHC ) 11/5/2006 AB/BI D.Kramer

2 What is BLM_S Low sensitivity BLM pumped to approx. 10-5 torr
Based on Secondary Electron Emission from Ti electrode Placed mainly in the Collimation areas, close to IPs, LHC Dump etc… 11/5/2006 APC meeting

3 Interior of Secondary Emission Beam Loss Monitor
11/5/2006 APC meeting

4 Geant4 Simulation Results Secondary Emission Yield 0
Geant4 Simulation Results Secondary Emission Yield GeV

5 Geant4 Simulation Results SEY vs. Ti Signal electrode thickness
Beam line SEM screens BLM_S

6 Installation in the PSB dump line
Screen BLM_S ACEM Rad Hard camera 11/5/2006 APC meeting

7 2005 PSB measurements 11/5/2006 APC meeting

8 Comparison with results from PSI 250MeV continuous proton beam
11/5/2006 APC meeting

9 Modified SEM tested in PSI

10 2006 Measurements in PSB dump
Modified BLMS installed on the movable stage 19/4 1st data taken 4/5 with up to 250e10 protons/bunch (AD user) maximum intensity allowed by the BLM system Access due to HV contact 10/5 11/5/2006 APC meeting

11 Linearity of the SEM response in 2006
11/5/2006 APC meeting

12 Simultaneous measurement with SEM and ACEM (PS BLM) equivalent to ~ 1e19 MIPs/s

13 Quench and Damage Levels
BLMS* & BLMC Quench level and observation range 450 GeV 7 TeV Damage levels Dynamic Arc: 108 Collimator: 1013 BLMS*: 3.2E13 protonen (nominal SPS injection) lost in about 10E-5 seconds. Special & Collimator1 turn Arc 2.5 ms 11/5/2006 APC meeting

14 Summary SEY from the first measurements in 2006: (5 ± 0.3)%
Good agreement with 5.7% from Geant4 No more problems with linearity Sufficient time response HV scan to be done (we need ~2h beam time) 11/5/2006 APC meeting