Download presentation
Presentation is loading. Please wait.
Published byTomás Rodríguez Rico Modified over 6 years ago
1
Overview of Sonoluminescence project at Academia Sinica & CIAE
Fong-Kai Lin(林楓凱) Tsz-King Wong(王子敬) Feb 2, 2005
2
Outline Background Collaboration Experiment in Oak Ridge National Lab.
Our Research Directions Progress at Academia Sinica Progress at CIAE Summary
3
Collaboration Academia Sinica CIAE (北京原子能院) NCU (中央大學) NCCU (中正大學)
NJU (南京大學)
4
Background Sonoluminescence found in 1930’s. (MBSL)
Gaitan made SBSL in 1989 Nuclear fusion in SL ? ORNL group first announced their observation in 2002 More convictive proof found in 2004 Key physical questions How hot/dense does it get inside the SL bubble? Light emission mechanism not clearly known
5
ORNL Experiment
6
Proof of Neutron Emission in ORNL’s Experiment
7
Our Research Direction
Understand light emission mechanism in SL -- Estimate the size of light emitting region in bubble by HBT method -- Pico-second timing measurement for SL pulse shape Study prospects of highER temperature emissions than optical -- Try to repeat ORNL’s experiment -- Detect UV emission in SL by fluorescent luminescence (To be reported by Yang Yi tomorrow)
8
Progress at Academia Sinica
Experimental setup and improvement Mechanical structure for angular measurement DAQ (LabView and Linux) Data Analysis (ROOT) Gas system Feedback control Different cavity configurations
9
Mechanical Structure
10
Setup – Gas System
11
Setup – DAQ VME Crate System Slot PMTs … VME-PCI Gate QDC Delay
PZT-driver Synchronous Output QDC Delay Tektronix 5054A oscilloscope PMT PC (LabView7.0) USB-GPIB
12
Setup--DAQ
13
Setup – Feedback Control
Resonance recedes as time passing! PMT QDC PC frequency Function Generator
14
Different Cavity Configuration
15
Progress at CIAE Target: to repeat the ORNL experiment Facility
CIAE Pulsed Neutron Generator Neutron detector PSD (pulse shape discriminator) and TOF (time of Flight) detector for particle discrimination and energy measurement
16
CIAE Facility – CPNG CIAE Pulsed Neutron Source 14MeV or 3MeV
1.5ns spill length, repetitive rate 1.5MHz 1010 neutrons per spill The small pipe side by side is for alpha measurement. Beamline
17
CIAE Facility – Detector
NE213 Liquid scintillation neutron detector Sensitive Area: Φ180mm×50mm Detect efficiency acceptable when E>1MeV
18
Summary SL research project initiated AS: Set up experimental tools
AS led, use HEP style/techniques to study the table-top experiment, an inter-discipline science AS: Set up experimental tools UV detection: result soon High acoustic pressure cavity CIAE: neutron generator and detection Repeat ORNL experiment Under preparation
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.