Presentation is loading. Please wait.

Presentation is loading. Please wait.

An accurate and complete empirical line list for water vapor

Similar presentations


Presentation on theme: "An accurate and complete empirical line list for water vapor"— Presentation transcript:

1 An accurate and complete empirical line list for water vapor
between 5850 – 7920 cm-1 D. Mondelain, A. Campargue, S. Kassi Laboratoire Interdisciplinaire de Physique Université Grenoble 1/CNRS S. Mikhailenko V.E. Zuev Institute of Atmospheric Optics, Tomsk, Russia

2 Water vapor absorption
Introduction Remote sensing of the Earth’s atmosphere requires an accurate characterization of the transparency windows Water vapor absorption = Local lines absorption H20 + Continuum absorption Next talk

3 Outline The CRDS technique and experimental setup
Line list for water vapor in the cm-1 region Conclusion

4 The CRDS technique

5 Cavity Ring Down  : ring down time Threshold Laser ON Laser OFF
Laser emission Ring-down events Time Cavity modes Frequency Threshold Frequency scan Laser OFF Laser ON  : ring down time

6 Cavity Ring Down L R R R= 0.99995  0 ~100 µs - Empty cell t0
Laser Out R R R=  0 ~100 µs time Intensity - Empty cell t0

7 Cavity Ring Down R R R= 0.99995  0 ~100 µs - Empty cell - With gas t
Laser Out R losses R=  0 ~100 µs time Intensity - Empty cell t - With gas t0

8 Experimental CRDS setup
Tdiode: -10°C – 60°C (~ 35 cm-1) Spectral sampling: 2×10-3 cm-1 80 DFB laser diodes 6nm/diode Large spectral coverage 5850 – 8330 cm-1 ( µm) + ECDL

9 An ultra-sensitive technique…
Typical noise level in routine: min~5×10-11 cm-1 2% light attenuation (~ km) S = 1.5 ×10-31 cm/molec min=5 ×10-13 cm-1 Kassi and Campargue, JCP (2012) 9

10 … with a high dynamics Dynamics > 4 orders of magnitude

11 An improved line list for water in the 5850-7920 cm-1 region
In coll. with S. Mikhailenko (IAO-Tomsk)

12 Fit of the recorded CRDS spectra
A Voigt profile is used for each observed lines. 10 Torr → List of empirical positions and intensities + vibration-rotation assignments (V1 V2 V3 J Ka Kc)

13 Origin of the data in our line list
M11: Mikhailenko et al, JMS 2011 L12: Leshchishina et al, JQSRT 2012 L13: Leshchishina et al, JQSRT 2013 Toth CRDS Data Calculated Data

14 Overview comparison with HITRAN2012
This work: lines (for the four main isotopologues) HITRAN: lines Difference mainly due to HD16O → Important limitation in the transparency windows +1372 HD18O lines HD17O lines

15 Some deficiencies in HITRAN2012
On positions… …and intensities

16 Adopted for the next edition of the GEISA database
Summary Complete: transitions for the 6 major isotopologues (cut-off of 1×10-29 cm/molecule). Empirical: positions rely on exp. determined energy levels. Evidence of some deficiencies in HITRAN2012: lack of HDO lines + some inaccurate pos. and intensities. Adopted for the next edition of the GEISA database

17 Improvements on line position accuracy
Typ. accuracy: 30 MHz (1x10-3 cm-1) obtained with wavemeters With a frequency comb (On fly measurements of beat note between DFB and comb teeth) Accuracy: < 500 kHz (without aver.) ~10 kHz (with aver.) In collab. with Politecnico di Milano

18 Campargue, S. Kassi, S. Mikhailenko,
Many thanks to… Campargue, S. Kassi, S. Mikhailenko, O. Leshchishina And LIA SAMIA


Download ppt "An accurate and complete empirical line list for water vapor"

Similar presentations


Ads by Google