Download presentation
Presentation is loading. Please wait.
Published byJean-Michel Chrétien Modified over 6 years ago
1
An accurate and complete empirical line list for water vapor
between 5850 – 7920 cm-1 D. Mondelain, A. Campargue, S. Kassi Laboratoire Interdisciplinaire de Physique Université Grenoble 1/CNRS S. Mikhailenko V.E. Zuev Institute of Atmospheric Optics, Tomsk, Russia
2
Water vapor absorption
Introduction Remote sensing of the Earth’s atmosphere requires an accurate characterization of the transparency windows Water vapor absorption = Local lines absorption H20 + Continuum absorption Next talk
3
Outline The CRDS technique and experimental setup
Line list for water vapor in the cm-1 region Conclusion
4
The CRDS technique
5
Cavity Ring Down : ring down time Threshold Laser ON Laser OFF
Laser emission Ring-down events Time Cavity modes Frequency Threshold Frequency scan Laser OFF Laser ON : ring down time
6
Cavity Ring Down L R R R= 0.99995 0 ~100 µs - Empty cell t0
Laser Out R R R= 0 ~100 µs time Intensity - Empty cell t0
7
Cavity Ring Down R R R= 0.99995 0 ~100 µs - Empty cell - With gas t
Laser Out R losses R= 0 ~100 µs time Intensity - Empty cell t - With gas t0
8
Experimental CRDS setup
Tdiode: -10°C – 60°C (~ 35 cm-1) Spectral sampling: 2×10-3 cm-1 80 DFB laser diodes 6nm/diode Large spectral coverage 5850 – 8330 cm-1 ( µm) + ECDL
9
An ultra-sensitive technique…
Typical noise level in routine: min~5×10-11 cm-1 2% light attenuation (~ km) S = 1.5 ×10-31 cm/molec min=5 ×10-13 cm-1 Kassi and Campargue, JCP (2012) 9
10
… with a high dynamics Dynamics > 4 orders of magnitude
11
An improved line list for water in the 5850-7920 cm-1 region
In coll. with S. Mikhailenko (IAO-Tomsk)
12
Fit of the recorded CRDS spectra
A Voigt profile is used for each observed lines. 10 Torr → List of empirical positions and intensities + vibration-rotation assignments (V1 V2 V3 J Ka Kc)
13
Origin of the data in our line list
M11: Mikhailenko et al, JMS 2011 L12: Leshchishina et al, JQSRT 2012 L13: Leshchishina et al, JQSRT 2013 Toth CRDS Data Calculated Data
14
Overview comparison with HITRAN2012
This work: lines (for the four main isotopologues) HITRAN: lines Difference mainly due to HD16O → Important limitation in the transparency windows +1372 HD18O lines HD17O lines
15
Some deficiencies in HITRAN2012
On positions… …and intensities
16
Adopted for the next edition of the GEISA database
Summary Complete: transitions for the 6 major isotopologues (cut-off of 1×10-29 cm/molecule). Empirical: positions rely on exp. determined energy levels. Evidence of some deficiencies in HITRAN2012: lack of HDO lines + some inaccurate pos. and intensities. Adopted for the next edition of the GEISA database
17
Improvements on line position accuracy
Typ. accuracy: 30 MHz (1x10-3 cm-1) obtained with wavemeters With a frequency comb (On fly measurements of beat note between DFB and comb teeth) Accuracy: < 500 kHz (without aver.) ~10 kHz (with aver.) In collab. with Politecnico di Milano
18
Campargue, S. Kassi, S. Mikhailenko,
Many thanks to… Campargue, S. Kassi, S. Mikhailenko, O. Leshchishina And LIA SAMIA
Similar presentations
© 2025 SlidePlayer.com. Inc.