Test Setup TPS1H100 EVM Supply voltage VS = 13.5V Electronic load

Similar presentations


Presentation on theme: "Test Setup TPS1H100 EVM Supply voltage VS = 13.5V Electronic load"— Presentation transcript:

1 Test Setup TPS1H100 EVM Supply voltage VS = 13.5V Electronic load
The current limit has an overshoot of around 35% higher than the limit set. The CS has a settling time of around 150uS but not deglitch time. If the output voltage decay slowly the CS signal has smooth transition. If the output voltage has fast transition the CS signal has fast transition and 150uS settling time

2 Current limit 2A and over current of 2
Current limit 2A and over current of 2.1A The output voltage decay slowly

3 Current limit 2A and over current of 10A The output voltage decay is very fast