Crosstalk Overview and Modes
2
Overview What is Crosstalk? Crosstalk Induced Noise
Effect of crosstalk on transmission line parameters Crosstalk Trends Design Guidelines and Rules of Thumb Crosstalk Overview
3
Crosstalk Induced Noise
Key Topics: Mutual Inductance and capacitance Coupled noise Circuit Model Transmission line matrices Crosstalk Overview
4
Mutual Inductance and Capacitance
Crosstalk is the coupling of energy from one line to another via: Mutual capacitance (electric field) Mutual inductance (magnetic field) Mutual Capacitance, Cm Mutual Inductance, Lm Zo Zo Zo Zo far far Cm Lm Zs near near Zs Zo Zo Crosstalk Overview
5
Mutual Inductance and Capacitance “Mechanism of coupling”
The circuit element that represents this transfer of energy are the following familiar equations The mutual inductance will induce current on the victim line opposite of the driving current (Lenz’s Law) The mutual capacitance will pass current through the mutual capacitance that flows in both directions on the victim line Crosstalk Overview
6
Crosstalk Induced Noise “Coupled Currents”
The near and far end victim line currents sum to produce the near and the far end crosstalk noise Zo Zo Zo Zo far far ICm Lm ILm near Zs near Zs Zo Zo Crosstalk Overview
7
Crosstalk Induced Noise “Voltage Profile of Coupled Noise”
Near end crosstalk is always positive Currents from Lm and Cm always add and flow into the node For PCB’s, the far end crosstalk is “usually” negative Current due to Lm larger than current due to Cm Note that far and crosstalk can be positive Zo Zo Far End Driven Line Un-driven Line “victim” Zs Near End Driver Zo Crosstalk Overview
8
Graphical Explanation
TD 2TD ~Tr far end crosstalk Near end V Time = 0 Zo Near end crosstalk pulse at T=0 (Inear) Far end crosstalk pulse at T=0 (Ifar) Zo V Time= 1/2 TD Zo V Time= TD Far end of current terminated at T=TD Zo V Time = 2TD Near end current terminated at T=2TD Crosstalk Overview
9
Crosstalk Equations Terminated Victim Far End Open Victim
TD Driven Line Un-driven Line “victim” Driver Zs Zo Near End Far End Terminated Victim A B Tr ~Tr Tr TD Far End Open Victim 2TD Zo Far End Driven Line Un-driven Line “victim” A B C Zs Near End Driver Zo Tr ~Tr ~Tr Crosstalk Overview 2TD
10
Crosstalk Equations TD Near End Open Victim Zo Zo Far End A C Driven Line B Un-driven Line “victim” Tr Tr Tr Zs Near End 2TD Driver 3TD The Crosstalk noise characteristics are dependent on the termination of the victim line Crosstalk Overview
11
Creating a Crosstalk Model “Equivalent Circuit”
The circuit must be distributed into N segments as shown in chapter 2 K1 L11(1) L22(1) C1G(1) C12(1) L11(2) L22(2) C1G(2) C12(2) C2G(2) C2G(1) L11(N) L22(N) C1G(N) C12(n) C2G(N) C1G C2G C12 Line 1 Line 2 Crosstalk Overview
12
Creating a Crosstalk Model “Transmission Line Matrices”
The transmission line Matrices are used to represent the electrical characteristics The Inductance matrix is shown, where: LNN = the self inductance of line N per unit length LMN = the mutual inductance between line M and N Inductance Matrix = Crosstalk Overview
13
Creating a Crosstalk Model “Transmission Line Matrices”
The Capacitance matrix is shown, where: CNN = the self capacitance of line N per unit length where: CNG = The capacitance between line N and ground CMN = Mutual capacitance between lines M and N Capacitance Matrix = For example, for the 2 line circuit shown earlier: Crosstalk Overview
14
Example Calculate near and far end crosstalk-induced noise magnitudes and sketch the waveforms of circuit shown below: Vsource=2V, (Vinput = 1.0V), Trise = 100ps. Length of line is 2 inches. Assume all terminations are 70 Ohms. Assume the following capacitance and inductance matrix: L / inch = C / inch = The characteristic impedance is: Therefore the system has matched termination. The crosstalk noise magnitudes can be calculated as follows: v R1 R2 Crosstalk Overview
15
Example (cont.) Near end crosstalk voltage amplitude (from slide 12):
Far end crosstalk voltage amplitude (slide 12): The propagation delay of the 2 inch line is: 100ps/div 200mV/div Thus, Crosstalk Overview
16
Effect of Crosstalk on Transmission line Parameters
Key Topics: Odd and Even Mode Characteristics Microstrip vs. Stripline Modal Termination Techniques Modal Impedance’s for more than 2 lines Effect Switching Patterns Single Line Equivalent Model (SLEM) Crosstalk Overview
17
Odd and Even Transmission Modes
Electromagnetic Fields between two driven coupled lines will interact with each other These interactions will effect the impedance and delay of the transmission line A 2-conductor system will have 2 propagation modes Even Mode (Both lines driven in phase) Odd Mode (Lines driven 180o out of phase) The interaction of the fields will cause the system electrical characteristics to be directly dependent on patterns Even Mode Odd Mode Crosstalk Overview
18
Odd Mode Transmission +1 -1 +1 -1
Potential difference between the conductors lead to an increase of the effective Capacitance equal to the mutual capacitance Electric Field: Odd mode Magnetic Field: Odd mode Because currents are flowing in opposite directions, the total inductance is reduced by the mutual inductance (Lm) V Drive (I) Induced (-ILm) I Lm Induced (ILm) Drive (-I) -I Crosstalk Overview
19
Odd Mode Transmission “Derivation of Odd Mode Inductance”
L11 I1 Mutual Inductance: Consider the circuit: + V1 - I2 + V2 - L22 Since the signals for odd-mode switching are always opposite, I1 = -I2 and V1 = -V2, so that: Thus, since LO = L11 = L22, Meaning that the equivalent inductance seen in an odd-mode environment is reduced by the mutual inductance. Crosstalk Overview
20
Odd Mode Transmission “Derivation of Odd Mode Capacitance”
Mutual Capacitance: Consider the circuit: C1g Cm C1g = C2g = CO = C11 – C12 V2 C2g So, And again, I1 = -I2 and V1 = -V2, so that: Thus, Meaning that the equivalent capacitance for odd mode switching increases. Crosstalk Overview
21
Odd Mode Transmission “Odd Mode Transmission Characteristics”
Impedance: Thus the impedance for odd mode behavior is: Explain why. Propagation Delay: and the propagation delay for odd mode behavior is: Crosstalk Overview
22
Even Mode Transmission
Since the conductors are always at a equal potential, the effective capacitance is reduced by the mutual capacitance Electric Field: Even mode Magnetic Field: Because currents are flowing in the same direction, the total inductance is increased by the mutual inductance (Lm) V Drive (I) Induced (ILm) I Lm Induced (ILm) Drive (I) I Crosstalk Overview
23
Even Mode Transmission Derivation of even Mode Effective Inductance
Mutual Inductance: Again, consider the circuit: L11 I1 + V1 - I2 + V2 - L22 Since the signals for even-mode switching are always equal and in the same direction so that I1 = I2 and V1 = V2, so that: Thus, Meaning that the equivalent inductance of even mode behavior increases by the mutual inductance. Crosstalk Overview
24
Even Mode Transmission Derivation of even Mode Effective Capacitance
Mutual Capacitance: Again, consider the circuit: V2 C1g Cm V2 C2g Thus, Meaning that the equivalent capacitance during even mode behavior decreases. Crosstalk Overview
25
Even Mode Transmission “Even Mode Transmission Characteristics”
Impedance: Thus the impedance for even mode behavior is: Propagation Delay: and the propagation delay for even mode behavior is: Crosstalk Overview
26
Odd and Even Mode Comparison for Coupled Microstrips
Even mode (as seen on line 1) Input waveforms Impedance difference V1 Odd mode (Line 1) Probe point Line 1 Line2 v1 v2 V2 Delay difference due to modal velocity differences Crosstalk Overview
27
Microstrip vs. Stripline Crosstalk Crosstalk Induced Velocity Changes
Chapter 2 defined propagation delay as Chapter 2 also defined an effective dielectric constant that is used to calculate the delay for a microstrip that accounted for a portion of the fields fringing through the air and a portion through the PCB material This shows that the propagation delay is dependent on the effective dielectric constant In a pure dielectric (homogeneous), fields will not fringe through the air, subsequently, the delay is dependent on the dielectric constant of the material Crosstalk Overview
28
Microstrip vs. Stripline Crosstalk Crosstalk Induced Velocity Changes
Odd and Even mode electric fields in a microstrip will have different percentages of the total field fringing through the air which will change the effective Er Leads to velocity variations between even and odd Microstrip E field patterns Er=1.0 Er=1.0 Er=4.2 Er=4.2 The effective dielectric constant, and subsequently the propagation velocity depends on the electric field patterns Crosstalk Overview
29
Microstrip vs. Stripline Crosstalk Crosstalk Induced Velocity Changes
If the dielectric is homogeneous (I.e., buried microstrip or stripline) , the effective dielectric constant will not change because the electric fields will never fringe through air Stripline E field patterns Er=4.2 Subsequently, if the transmission line is implemented in a homogeneous dielectric, the velocity must stay constant between even and odd mode patterns Crosstalk Overview
30
Microstrip vs. Stripline Crosstalk Crosstalk Induced Noise
The constant velocity in a homogeneous media (such as a stripline) forces far end crosstalk noise to be zero Since far end crosstalk takes the following form: Far end crosstalk is zero for a homogeneous Er Crosstalk Overview
31
Termination Techniques Pi and T networks
Single resistor terminations described in chapter 2 do not work for coupled lines 3 resistor networks can be designed to terminate both odd and even modes T Termination +1 Odd Mode Equivalent -1 R1 R2 Virtual Ground in center -1 R1 R2 R3 +1 Even Mode Equivalent R1 R2 2R3 Crosstalk Overview
32
Termination Techniques Pi and T networks
The alternative is a PI termination PI Termination R1 R1 +1 ½ R3 Odd Mode Equivalent R3 -1 ½ R3 R2 R2 -1 +1 R1 Even Mode Equivalent +1 R2 Crosstalk Overview