Presentation is loading. Please wait.

Presentation is loading. Please wait.

PHASE IDENTIFICATION UNIT (PIU)

Similar presentations


Presentation on theme: "PHASE IDENTIFICATION UNIT (PIU)"— Presentation transcript:

1 PHASE IDENTIFICATION UNIT (PIU)
O&M TRAINING COURSE

2 TABLE OF CONTENTS PHASE IDENTIFICATION UNIT - TRAINING
TRAINING OBJECTIVES TO CANCEL THE REFERENCE THEORY OF OPERATION TO TOGGLE PHASE ROTATION PIU BUTTONS TO MEASURE THE PHASE PIU DISPLAY TO UPLOAD DATA TO THE REMOTE REFERENCE CHECKING THE BATTERY CAPACITY WAKING FROM SHIPMENT REMOVING THE UNITS COVER TO INSTALL THE SIM CARD CHARGING THE PIU TO DOWNLOAD THE PIU UTILITY TURNING THE PIU ON AND OFF TO CONFIGURE THE PIU CONFIRM CONNECTIVITY TO INSTALL A REMOTE REFERENCE TO SET THE REFERENCE SELECT A TOPIC OR ENTER TO CONTINUE TO ROTATE THE REFERENCE

3 Removing the Units Cover
Theory of Operation Removing the Units Cover Charging the PIU Power Up/Down Confirm Connectivity Set the PIU Reference Identify the Phase Upload Measured Data PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS TRAINING OBJECTIVES Operation

4 TRAINING OBJECTIVES - Maintenance
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS Waking from Shipping Installing the SIM Card Fitting the E-Field Probe Downloading the PIU Utility Configuring the PIU Installing a Remote Reference Unit TRAINING OBJECTIVES - Maintenance

5 THEORY OF OPERATION PHASE IDENTIFICATION UNIT - TRAINING
TABLE OF CONTENTS THEORY OF OPERATION PIU MEASURES THE PHASE OF THE E-FIELD FROM THE PROPERTY REFERENCE PHASE SENT TO PIU REFERENCE MEASURES PHASE OF ITS MAINS SUPPLY TIMED TOGETHER BY SATELLITE PULSES

6 F1 F2 F3 F4 PIU BUTTONS PHASE IDENTIFICATION UNIT - TRAINING
TABLE OF CONTENTS PIU BUTTONS F1 F2 F3 F4

7 PIU DISPLAY PHASE IDENTIFICATION UNIT - TRAINING D1 : E-FIELD STRENGTH
TABLE OF CONTENTS PIU DISPLAY D1 : E-FIELD STRENGTH D2 : BATTERY LEVEL PHASE VECTORS D1 LED : PHASE ROTATION DIRECTION D2 LED : REMOTE REFERENCE CONNECTIVITY

8 CHECKING THE BATTERY CAPACITY
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS CHECKING THE BATTERY CAPACITY BATTERY CAPACITY INDICATED ON D2 SHORT PRESS ON F3

9 REMOVING THE UNITs COVER
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS REMOVING THE UNITs COVER PRESS BOTH SIDES IN

10 CHARGING THE PIU PHASE IDENTIFICATION UNIT - TRAINING CHARGING LED
TABLE OF CONTENTS CHARGING THE PIU CHARGING LED USB CONNECTOR 12V D.C. INPUT

11 POWER UP PHASE IDENTIFICATION UNIT - TRAINING PRESS AND HOLD F1
TABLE OF CONTENTS POWER UP PRESS AND HOLD F1 For 3 SECS

12 POWER UP PHASE IDENTIFICATION UNIT - TRAINING FLASHING F1 LED
TABLE OF CONTENTS POWER UP FLASHING F1 LED DURING POWER UP

13 POWER UP PHASE IDENTIFICATION UNIT - TRAINING
TABLE OF CONTENTS POWER UP ON COMPLETION OF POWER UP UNIT WILL FLASH D1 AND D2 SCALES AND BE READY FOR OPERATION

14 PRESS AND HOLD F1 AND F2 TOGETHER
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS POWER DOWN PRESS AND HOLD F1 AND F2 TOGETHER For 3 SECS

15 POWER DOWN PHASE IDENTIFICATION UNIT - TRAINING
TABLE OF CONTENTS POWER DOWN D2 LED GOING OFF INDICATES THAT THE UNIT IS POWERING OFF

16 CONFIRM CONNECTIVITY PHASE IDENTIFICATION UNIT - TRAINING
TABLE OF CONTENTS CONFIRM CONNECTIVITY SOLID VECTOR BAR(S) INDICATE GOOD GPS RECEPTION D2 LED ON SOLID INDICATES CONNECTIVITY TO REMOTE REFERENCE

17 TO SET THE REFERENCE PHASE IDENTIFICATION UNIT - TRAINING
TABLE OF CONTENTS TO SET THE REFERENCE HOLD UNIT CLOSE TO A KNOWN PHASE SOURCE WITH D1 INDICATING A HIGH SIGNAL – FOR AT LEAST 20 SECONDS SOLID L1 VECTOR INDICATES REFERENCE SET CORRECTLY THEN A SHORT PRESS ON F2

18 TO ROTATE THE REFERENCE
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS TO ROTATE THE REFERENCE L1 WILL ROTATE TO L2 PRESS AND HOLD F2 FOR 3 SEC THEN A SHORT PRESS ON F3 AND RELEASE BOTH BUTTONS REPEAT FOR FURTHER ROTATION

19 TO TOGGLE THE PHASE ROTATION
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS TO TOGGLE THE PHASE ROTATION PRESS AND HOLD F1 For 3 SECS THEN RELEASE F1 AND THEN RELEASE F3 TO POWER UP REVERSING THE PHASE ROTATION WHILE POWERED DOWN PRESS AND HOLD F3 AND

20 TO TOGGLE THE PHASE ROTATION
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS TO TOGGLE THE PHASE ROTATION D1 LED WILL REMAIN ON INDICATING AN ANTI-CLOCKWISE PHASE ROTATION WHILST POWERED ROTATING THE REFERNCE WILL NOW GO IN AN ANTI-CLOCKWISE DIRECTION

21 TO CANCEL THE REFERENCE
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS TO CANCEL THE REFERENCE ALL VECTORS WILL COME ON WHEN THE REFERENCE HAS BEEN CANCELLED PRESS AND HOLD F1 FOR 3 SEC THEN A SHORT PRESS ON F2 AND RELEASE

22 TO MEASURE THE PHASE PHASE IDENTIFICATION UNIT - TRAINING
TABLE OF CONTENTS TO MEASURE THE PHASE HOLD THE UNIT AS CLOSE AS POSSIBLE TO A PROPERTY FOR EXAMPLE L3 INDICATED IF THE VECTOR IS STABLE FOR AT LEAST 10 SEC THEN THIS IS THE CORRECT PHASE INDICATION

23 TO UPLOAD DATA TO THE REMOTE REFERENCE
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS TO UPLOAD DATA TO THE REMOTE REFERENCE HOLD THE UNIT AS CLOSE AS POSSIBLE TO A PROPERTY FOR EXAMPLE L3 INDICATED PRESS AND HOLD F1 FOR 3 SEC THEN RELEASE

24 WAKING FROM SHIPMENT (or depleted BATTERY)
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS WAKING FROM SHIPMENT (or depleted BATTERY) QUICKLY FLASHING CHARGING LED FOR SHORT PERIOD USB CONNECTOR 12V D.C. INPUT

25 INSTALLING THE SIM CARD
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS INSTALLING THE SIM CARD SIM CARD HOLDER (INSERT WITH CARD CHAMFER AT TOP LEFT CORNER)

26 DOWNLOADING THE PIU UTILITY
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS DOWNLOADING THE PIU UTILITY USING YOUR INTERNET BROWSER, NAVIGATE TO: CLICK ON ‘PIU UTILITY APPLICATION’

27 PUTTING THE PIU INTO CONFIGURATION MODE
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS PUTTING THE PIU INTO CONFIGURATION MODE PRESS AND HOLD F1 For 3 SECS THEN RELEASE F1 AND THEN RELEASE F4 PRESS AND HOLD F4 AND

28 PUTTING THE PIU INTO CONFIGURATION MODE
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS PUTTING THE PIU INTO CONFIGURATION MODE UNIT WILL POWER UP WITH F4 LED REMAINING ON INDICATING THE UNIT IS IN CONFIGURATION MODE

29 PUTTING THE PIU INTO CONFIGURATION MODE
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS PUTTING THE PIU INTO CONFIGURATION MODE FOLLOWING CONFIGURATION PRESS AND HOLD F4 For 3 SECS TO FULLY POWER UP

30 CONFIGURING THE PIU - CONNECTING
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS CONFIGURING THE PIU - CONNECTING REMOVE THE PIU COVER CONNECT THE PIU (IN CONFIGURATION MODE) TO A PC VIA THE USB CONNECTOR START THE PIU UTILITY UNIT IDENTIFIED AS PIU AND CONNECTED

31 CONFIGURING THE PIU - Entering the IP Address
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS CONFIGURING THE PIU - Entering the IP Address SELECT IP ADDRESS ENTER IP ADDRESS AND PORT NUMBER OF REMOTE REFERENCE CLICK ‘SAVE’

32 CONFIGURING THE PIU - Entering the APN Details
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS CONFIGURING THE PIU - Entering the APN Details SELECT APN DETAILS ENTER APN NAME USER NAME AND PASSWORD OF MOBILE NETWORK CLICK ‘SAVE’ CONFIGURATION COMPLETE – Disconnect the PIU

33 INSTALLING A REMOTE REFERENCE
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS INSTALLING A REMOTE REFERENCE PIU UTILITY INSTALLED MAINS CHARGER AC OUTPUT USB CABLE

34 INSTALLING A REMOTE REFERENCE
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS INSTALLING A REMOTE REFERENCE TABS CHANGE AUTOMATICALLY UNIT AUTOMATICALLY IDENTIFIED AS RRU AND CONNECTED

35 INSTALLING A REMOTE REFERENCE – Configure the Server
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS INSTALLING A REMOTE REFERENCE – Configure the Server SELECT SERVER TAB ENTER IP ADDRESS OF PC AND PORT NUMBER ENTERED INTO PIU PRESS DISCOVER TO AUTOMATICALLY DISCOVER THE PC IP ADDRESS AND PRESS SAVE

36 INSTALLING A REMOTE REFERENCE – Activate the Bridge
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS INSTALLING A REMOTE REFERENCE – Activate the Bridge ACTIVATE THE BRIDGE

37 INSTALLING A REMOTE REFERENCE
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS INSTALLING A REMOTE REFERENCE SERVER READY DISPLAYS THE NUMBER OF PIUs CONNECTED

38 INSTALLING A REMOTE REFERENCE – Logging the Data
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS INSTALLING A REMOTE REFERENCE – Logging the Data ACTIVATE THE LOG OF PIU UPLOADED DATA ACTIVATE THE LOG OF REFERENCE DATA

39 INSTALLING A REMOTE REFERENCE – Closing the PIU Utility
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS INSTALLING A REMOTE REFERENCE – Closing the PIU Utility MINIMISE OR CLOSE FINAL WARNING!

40 UPLOADED DATA ON GOOGLE EARTH
PHASE IDENTIFICATION UNIT - TRAINING TABLE OF CONTENTS UPLOADED DATA ON GOOGLE EARTH


Download ppt "PHASE IDENTIFICATION UNIT (PIU)"

Similar presentations


Ads by Google