Download presentation
Presentation is loading. Please wait.
Published byKeely Starr Modified over 10 years ago
1
DRAM background Fully-Buffered DIMM Memory Architectures: Understanding Mechanisms, Overheads and Scaling, Garnesh, HPCA'07 CS 8501, Mario D. Marino, 02/08
2
DRAM Background
3
Typical Memory Busses: address, command, data, DIMM (Dual In-Line Memory Module) selection
4
DRAM cell
5
DRAM array
6
DRAM device or chip
7
Command/data movement: DRAM chip
8
Operations(commands) protocol, timing
9
Examples of DRAM operations(commands)
11
The purpose of a row access command is to move data from the DRAMarrays to the sense amplifiers. tRCD and tRAS
12
A column read command moves data from the array of sense amplifiers of a given bank to the memory controller. tCAS, tBurst
13
Precharge: separate phase that is a prerequisite for the subsequent phases of a row access operation (bitlines set to Vcc/2 or Vcc)
14
Organization, access, protocols
15
Logical Channels: set of physical channels connected to the same memory controller
16
Examples of Logical Channels
17
Rank = set of banks
19
Row = DRAM page
20
Width: aggregating DRAM chips
21
Scheduling: banks
22
Scheduling banks
23
Scheduling: ranks
24
Open x Close page Open-page: data access to and from cells requires separate row and column commands – Favors accesses on the same row (sense aps open) – Typical general purpose computers (desktop/laptop) Close-page: – Intense amount of requests, favors random accesses – Large multiprocessor/multicore systems
25
Available Parallelism in DRAM System Organization Channel: Pros: performance different logical channels, independent memory controllers schedulling strategies cons Number of pins, power to deliver Smart but not adaptive firmware
26
Available Parallelism in DRAM System Organization Rank pros accesses can proceed in parallel in different ranks (busses availability) cons Rank-to-rank switching penalties in high frequency Globally synchronous DRAM (global clock)
27
Available Parallelism in DRAM System Organization Bank Different banks (busses availability) Row Only 1 row/bank can be active at any time period Column Depends on management (close-page / open-page)
28
Paper: Fully-Buffered DIMM Memory Architectures: Understanding Mechanisms, Overheads and Scaling, Garnesh, HPCA'07
30
Issues parallel bus scaling: frequency, widths, length, depth (man hops => latency ) #memory controllers increased CPUs, GPUs – #DIMMs/channel (depth) decreases 4DIMMs/channel in DDRs 2 DIMMs/channel in DDR2 1 DIMM/channel in DDR3 scheduling
31
Contributions Applied DDR based memory controller policies in FBDIMM memory Evaluation of Performance Exploit FBDIMM depth: rank (DIMM) parallelism latency and bandwidth for FBDIMM and DDR – high utilization of the channels, FBDIMM 7% in latency 10% – low utilization of the channels 25% in latency 10 % in bandwidth
32
Northbound channel: reads / Southbound-channel: writes AMB: pass-through switch, buffer, serial/parallel converter
33
Methodology DRAMsim simulator Execution-driven simulator Detailed models of FBDIMM and DDR2 based on real standard configurations Standalone / coupled with M5/SS/Sesc Benchmarks: bandwidth-bound SVM from Bio-Parallel (r:90%) SPEC-mixed: 16 independent (r:w = 2:1) UA from NAS (r:w = 3:2) ART (SPEC-2000, OpenMP) (r:w = 2:1)
34
Methodology: cont Different scheduling policies: greedy, OBF, most/last pending and RIFF 16-way CMP, 8MB L2 Multi-threaded traces gathered with CMP$im SPEC traces using Simplescalar with 1MB L2, in-order core 1 rank/DIMM
35
High-bandwidth utilization: – Better bandwidth: FBDIMM – Larger latency
36
ART and UA: latency reduction
37
Low utilization: serialization cost Depth: FBDIMM scheduler offsets serialization
38
Overhead: queue, south and rank availability Single-rank: higher latency
39
Scheduling Best: RIFF, priority on reads than writes
40
Bandwidth is less sensitive th Higher latency in open-page mode More channels => decreases channel utilization
Similar presentations
© 2025 SlidePlayer.com. Inc.