Energy Management System at AD ELEM REK Bitola

Similar presentations


Presentation on theme: "Energy Management System at AD ELEM REK Bitola"— Presentation transcript:

1 Energy Management System at AD ELEM REK Bitola

2 Dedication “Aware of the fact that the Energy Production sector, is also a serious energy consumer, we recognize the need for raising awareness and changing the attitude towards a more responsible energy consumption. Therefore, as a corporate socially responsible company, we feel the obligation to show leadership in the rational use and management of energy resources, with which we represent an example to our consumers“ Excerpt from the Energy Policy of AD ELEM 2

3 Benefits from the implementation of EnMS
Energy costs decrease Decision-making process based on information Decreased influence on the environment Improved sustainability practices Improved operational efficiency Positive publicity Improvement of the Corporate image of the company 3

4 Scope and Boundaries of EnMS
4

5 Significant Energy Users (SEUs)
Own Consumption ID SEUs Driver Is SEUs measured ? Auto / manual % of the total consumption Who influences the operation of SEUs? 1 Mills Production DCS System 23% Operator 2 Charging pumps 25% 3 Circulation pumps 7% 4 Condens. Pumps 4% 5 CAV and VDG 28% Total SEUs 86% Remainder 14% Total consumption 100% 5

6 Regression model of own consumption in 2015 based on daily data
Energy Performance Monitoring – Baseline and setting Energy Performance Indicators Own Consumption Own Consumption (Own Consumption Production Regression model of own consumption in 2015 based on daily data 6

7 Workshop with the employees for definition of the possibilities for improvement of REK Bitola
Participants Employees that operated and maintain the SEUs Management team of REK Bitola Work group for implementation of EnMS Agenda Introduction to the EnMS Completion of questionnaires, discussion regarding improvements and preparation of the list of possible improvements (objectives), next steps, definition of the needs of training 7

8 Energy Efficiency measures
ID Project description/measure/action Status Estimated/Actual (Annual) Savings Assets spent Return period Electricity [MWh] Finances (euro) 1 Clean Air Ventilators operating (CAV) in first gear on lower power Underway 6.063 2 Operation with five (5) mills under conditions of decreased power Not implementing 3 Optimum size and regulation of 6 KV voltage Implemented 169 6.791 4 Location and repair of air leakages from boiler to chimney of Block 2 5 Vacuum increase on the condenser with continuous use of the cleaning system of the condenser (taproge) Implemented on Block 3 504 20.160 Operation costs 8

9 Actual savings vs. target savings
CAV on Block 3 operating in second gear Only Block 3 operating with one CAV in first gear Production decrease because of decreased consumption Block 2 and Block 3 operating with one CAV in first gear each Target savings in comparison to realized savings 2016 9

10 Regression model of own consumption in 2016 based on daily data
Energy Performance Monitoring – Baseline and setting Energy Performance Indicators Regression model of own consumption in 2016 based on daily data 10

11 Actual savings vs. target savings 2017
Actual savings in comparison to realized savings in 2017 11

12 Future steps Formation of a group for Energy Efficiency of AD ELEM
Implementation of EnMS with all the affiliates of AD ELEM Realization of target savings of AD ELEM through the realization of new improvement measures and implementation of Energy Efficient projects 12

13 Thank you for the attention
Mirko Ristevski AD ELEM REK Bitola


Download ppt "Energy Management System at AD ELEM REK Bitola"