Presentation is loading. Please wait.

Presentation is loading. Please wait.

by Yoshiyasu Aoki, Giovanna Tosato, Terry W

Similar presentations


Presentation on theme: "by Yoshiyasu Aoki, Giovanna Tosato, Terry W"— Presentation transcript:

1 Serum viral interleukin-6 in AIDS-related multicentric Castleman disease
by Yoshiyasu Aoki, Giovanna Tosato, Terry W. Fonville, and Stefania Pittaluga Blood Volume 97(8): April 15, 2001 ©2001 by American Society of Hematology

2 Microscopic morphology of representative lymph node sections and immunohistochemical detection of KSHV infection.(A) Small hyalinized germinal center surrounded by concentric layers of small lymphocytes (hematoxylin and eosin stain; × 100). Microscopic morphology of representative lymph node sections and immunohistochemical detection of KSHV infection.(A) Small hyalinized germinal center surrounded by concentric layers of small lymphocytes (hematoxylin and eosin stain; × 100). (B) Interfollicular sheets of plasma cells are shown (hematoxylin and eosin stain; × 1000). (C) KSHV-LANA antigen detection in the lymph node mantle zone visualized by immunohistochemical staining with monoclonal antibody (× 200). The inset shows the characteristic speckled nuclear pattern (× 1000). (D) vIL-6 detection in immunoblastic cells in the lymph node mantle zone (× 100). The insets show specific cytoplasmic staining (× 1000). Yoshiyasu Aoki et al. Blood 2001;97: ©2001 by American Society of Hematology

3 Detection of vIL-6, hIL-6, and HIV RNA in serial serum samples from an HIV-positive patient with MCD.On day 1, prednisone treatment was initiated. vIL-6 levels were measured by a vIL-6–specific enzyme-linked immunosorbent assay (ELISA) established in our la... Detection of vIL-6, hIL-6, and HIV RNA in serial serum samples from an HIV-positive patient with MCD.On day 1, prednisone treatment was initiated. vIL-6 levels were measured by a vIL-6–specific enzyme-linked immunosorbent assay (ELISA) established in our laboratory.6 hIL-6 was measured by a commercially available ELISA kit (R&D Systems, Minneapolis, MN) that does not detect vIL-6.6 The lower limit of ELISAs sensitivity in serum was calculated to be 300 pg/mL of vIL-6 and 1.0 pg/mL of hIL-6. HIV-RNA load was measured by Amplicor HIV-1 reverse transcriptase–polymerase chain reaction test (Roche Diagnostic Systems, Basel, Switzerland), kindly performed by Dr Timothy Alcorn, Laboratory Corporation of America. 3TC indicates lamivudine; d4T, stavudine; and NFV, nelfinavir. Yoshiyasu Aoki et al. Blood 2001;97: ©2001 by American Society of Hematology


Download ppt "by Yoshiyasu Aoki, Giovanna Tosato, Terry W"

Similar presentations


Ads by Google