WLTP-DTP Subgroup Additional Pollutants VP2 Results
Date: 10. Dec. 2012 WLTP-DTP-AP, Mörsch/Astorga
2
Validation NO2 Measurement
So far, additional data from 6 labs received: 11 Vehicles 157 Tests with modal and bag results for NO All labs used CLD Data is sufficient to close open issue Analysis Vehicles Repititions UTAC VP2 CLD 6 3 IAV GM ACEA 2 TÜV no modal data DEKRA EMPA Bosmal no answer Maruti Korea WLTP-DTP-AP, Mörsch/Astorga
3
NO2: Open Issue Should measurement of NO or NO2 from bag be allowed as alternative to modal measurement? WLTP-DTP-AP, Mörsch/Astorga
4
NO2: measurement from bag versus modal measurement
Measurement from bag systematically yields higher concentration of NO2 This is due to the reaction of NO to NO2 in the bag To avoid error modal measurement is required WLTP-DTP-AP, Mörsch/Astorga
5
NO2: Repeat Measurements
Repeat measurements (3 to 6 tests) show identical scatter for bag and modal measurement of NO WLTP-DTP-AP, Mörsch/Astorga
6
NO2: Zero scatter Basis: 96 results from vehicle with very low NO2 emission Scatter from modal measurement smaller than from bag Concentration ca. 0,1 ppm higher Modal measurement is reliable WLTP-DTP-AP, Mörsch/Astorga
7
NO2: Conclusion To avoid significant systematic error due to reaction in the bag modal measurement is required Modal measurement is almost as robust as bag measurement WLTP-DTP-AP, Mörsch/Astorga
8
Validation N2O Measurement
Only few labs have submitted data No measurements of two systems in parallel Data is not sufficient for validation but no open issues WLTP-DTP-AP, Mörsch/Astorga
9
Validation NH3 Measurement
Only few labs have submitted data Only few measurements of two systems in parallel, no correlation Data is not sufficient to close open issues WLTP-DTP-AP, Mörsch/Astorga
10
Open issues for NH3 sampling and measurements
In Situ extractive Approach to solve Sampling during engine off x xx request to labs to collect data Lost sample x theoretical approach Go to diluted measurement? open issue Addition of diluent x diluent according spec for pure gases Calibration x Loss of NH3 in sample system x best practice/literature Temperature of analyser (FTIR) x technical discussion Temperature condition x best practice/literature Temperature and material x best practice/literature of sampling lines Filter material x best practice/literature WLTP-DTP-AP, Mörsch/Astorga
11
Validation of measurement of EtOH and Aldehydes
No data from VP2 Additional measurement campaign necessary At least two weeks, ca. sept (depending on availability of instruments) JRC will host (to be confirmed) Instrument manufacturers methods: AVL Horiba Innova (to be verified) MAHA Sensors GC-Method FTIR Call for instruments (on CIRCA) Vehicles: 2 different FFV, 2 Gasoline WLTP-DTP-AP, Mörsch/Astorga