Download presentation
Presentation is loading. Please wait.
Published byKamron Holway Modified over 10 years ago
1
Workplace Emergency Planning & Preparedness Medford Fire Prevention Bureau Based on the 2007 Oregon Fire Code
2
Occupancy Classification Groups –A-Assembly –B-Business –E-Educational –F-Factory, Industrial –H-Hazardous –I-Institutional –M-Mercantile –R-Residential –SR-Special Residential –S-Storage –U-Miscellaneous (OFC 202) Source: (OFC 202)
3
Includes Fire Evacuation and Fire Safety Plans Includes Fire Evacuation and Fire Safety Plans When Required: –Group A, except worship areas <2000 occupants –Group B, 500 or more occupants; 100 above or below lowest level of exit discharge –Group E –Group H –Group I –Group R-2 college and university buildings; Group R-4; Group R subject to licensure by state –Group SR –High Rise –Group M, 500 or more occupants; 100 above or below lowest level of exit discharge –Covered Malls >50,000 sq. ft. –Underground buildings –Group A, E, or M buildings with atriums (OFC 404) Source: (OFC 404) Emergency Planning
4
Why Have an Emergency Plan? Why Have an Emergency Plan? –To prevent fatalities and injuries –To reduce damage to buildings and contents –To accelerate the resumption of normal operations –Because the fire code requires it Consider: Consider: –There are approximately 75,000 fires annually that cost businesses over $2 billion –These fires kill more than 200 and injure more than 5,000 people each year –45% of businesses never reopen after a fire due to the high cost of recovery and repairs Sources: OSHA, Oregon Fire Code, NFPA, OSHA, and Numerous Business Emergency Plans. Emergency Planning
5
Fire Evacuation Plans To Prepare for and Define the Roles for Evacuation and Relocation of Occupants During an Emergency To Prepare for and Define the Roles for Evacuation and Relocation of Occupants During an EmergencyIncludes: –Emergency egress or escape routes –Procedures for employees: »Who remains to operate critical equip. before evacuating »To account for employees and occupants –ID those: »Responsible for rescue or medical aid »Who can be contacted for further information –ID preferred and alternative means of notifying occupants of a fire or emergency –Preferred and any alternative means of notifying fire department or appropriate emergency organization (OFC 404.3.1) Source: (OFC 404.3.1)
6
Staff Duties and Responsibilities Staff Duties and Responsibilities –Emergency coordinator –Chain of command –Alternative communication center –Address who will assist disabled workers –A system for accounting for personnel and non-personnel following an evacuation –Identify who is trained and willing to deal with casualties Sources: Oregon Fire Code, NFPA, OSHA, and Numerous Business Emergency Plans. Fire Evacuation Plans
7
Fire Safety Plans How to React to an Emergency; Building Site Layout and Hazards How to React to an Emergency; Building Site Layout and Hazards –How to React to an Emergency »Procedure to report an emergency »Activating an emergency plan »Procedure for alerting staff »Ordering an evacuation –ID personnel responsible for systems and equip. installed to prevent or control fires –ID personnel responsible for maintenance, housekeeping, and controlling fuel hazard sources –List of major fire hazards Sources: Oregon Fire Code, NFPA, OSHA, and Numerous Business Emergency Plans.
8
Fire Safety Plans Also Includes: –Site Plans –Floor Plans Clearly Posted Throughout Building Showing: »Evacuation routes and alternate means of escape for each room or portion of the occupancy »Accessible egress routes »Designated Safe Areas »Fire alarm pull stations »Fire alarm control panels »Fire extinguishers and manual fire extinguishing equipment »Area separation walls »First aid areas (OFC 404.3.2) Source: (OFC 404.3.2)
9
Fire Safety and Evacuation Plans
10
Fire Safety Plans Emergency Plan Guidelines and Procedures Emergency Plan Guidelines and Procedures –Fire –Earthquakes –Explosion –Bomb threats –Chemical spills –Workplace violence –Utility Failure –Medical emergency –Triage Sources: Oregon Fire Code, NFPA, OSHA, and Numerous Business Emergency Plans.
11
Records Records –Emergency contact numbers: –Emergency dispatch –Hospitals –Utility companies –Government agencies –Alarm company –Sprinkler company –Any other responsible parties –Documentation of drills should include the date and time of each drill, the person conducting the drill and other information relative to the drill. –Updated list of employee emergency contact information Sources: Oregon Fire Code, NFPA, OSHA, and Numerous Business Emergency Plans. Fire Evacuation and Safety Plans
12
Maintenance Maintenance –Shall be reviewed or updated annually or as necessitated by changes in: »Staff assignments »Occupancy »Physical arrangement of building Availability Availability –Shall be available in the workplace for reference and review by employees –Shall be available to fire code official for review upon request (OFC 404) Source: (OFC 404) Fire Evacuation and Safety Plans
13
Emergency Evacuation Drills Purpose of Fire Drills Purpose of Fire Drills –To be ready should an occurrence happen, increasing the chanced of survival. A disorganized evacuation can lead to confusion, injury, death and property damage. When Required When Required –Group A: quarterly for employees only –Group B: annually »500 or more occupants; 100 above or below lowest level of exit discharge –Group E: monthly complete evacuation. –Group I: quarterly each shift for staff only. –Group R1: quarterly each shift for staff only. –Group R-2 (college and university): quarterly all occupants –Group R-4 & SR: see IFC 408.1.2. –High Rise: annually employees only (OFC 405) Source: (OFC 405)
14
Staff Training Emergency Egress and Relocation Drills Emergency Egress and Relocation Drills –Shall be held with sufficient frequency to familiarize occupants with the drill procedure and to establish conduct of the drill as a matter of routine. –Planning and conduct of drills shall be assigned only to competent persons. –To be held at expected and unexpected times and under varying conditions. –Shall be Initiated by the fire alarm system when present –Drill participants shall relocate to a predetermined location and remain at such until a recall or dismissal signal is given. –Orderly evacuation should receive priority over the speed of evacuation. –Occupants should be accounted for. –A record shall be kept. Sources: Oregon Fire Code, NFPA, OSHA, and Numerous Business Emergency Plans.
15
Staff Training In case of fire, think RACE: In case of fire, think RACE: –Rescue all persons in immediate area –Alarm: announce the fire- Pull alarm and dial 911 –Confine the fire by closing doors –Evacuate/Extinguish Sources: Oregon Fire Code, NFPA, OSHA, and Numerous Business Emergency Plans.
16
Staff Training Fire Extinguisher Training Fire Extinguisher Training –Decision –Only use if the fire is small and contained, and not spreading beyond its starting point and not spreading beyond its starting point –Do not waste time in trying to fight the fire if the fire might block your only way out –Proper extinguisher use, think PASS: –Pull trigger pin (Stand back several feet away from fire) –Aim low, point the nozzle at the base of the fire –Squeeze trigger –Sweep from side to side until the fire appears to be out Medical Training Medical Training –First aid, CPR, etc. Safety Equipment Safety Equipment –First aid kits, hardhats, goggles, eye washing facilities, breathing apparatus, etc. Fire Prevention-Monthly Inspections Fire Prevention-Monthly Inspections Sources: Oregon Fire Code, NFPA, OSHA, and Numerous Business Emergency Plans.
17
Staff Training Fire Protection Systems (Alarms and Sprinklers) Fire Protection Systems (Alarms and Sprinklers) –Train employees how your particular system works –Employees should be familiar with fire alarm signals –Smoke alarms detect smoke, sprinklers are set off by heat –Smoke alarms systems are early warning devices, allowing precious time to evacuate –Fire sprinkler systems are designed to control the fire –Normally one or two sprinklers will discharge, not the whole system Sources: Oregon Fire Code, NFPA, OSHA, and Numerous Business Emergency Plans.
18
Video Getting Out Alive Getting Out Alive Complete Fire Prevention Library, The Idea Bank Source: Complete Fire Prevention Library, The Idea Bank
19
Fire Prevention
20
Access/Premises
21
Egress Hazards Buildings or structures that are not provided with adequate means of egress or emergency escapes are unsafe and shall be subject to the abatement procedures specified in Section 110. (OFC 1001.3)
22
Egress Hazards-Locked Exits
23
Emergency Lighting/Illumination Existing Buildings, Where Required: A>50 (Except Churches 50 (Except Churches <300) B three or more stories and 100 or more occupants above or below level of exit discharge B three or more stories and 100 or more occupants above or below level of exit discharge B 1,000 or more occupants B 1,000 or more occupants E exitways and windowless areas of occupancy E exitways and windowless areas of occupancy F>100 (Except buildings used only in daylight with windows) F>100 (Except buildings used only in daylight with windows) I M (Except buildings <3000 sq. ft on one story only) M (Except buildings <3000 sq. ft on one story only) R-1 (Except where each guestroom has direct outdoor grade level access) R-1 (Except where each guestroom has direct outdoor grade level access) R-2 (Except where each guestroom has direct outdoor grade level access) R-2 (Except where each guestroom has direct outdoor grade level access) R-4 (Except where each guestroom has direct outdoor grade level access) R-4 (Except where each guestroom has direct outdoor grade level access) (OFC 1027.5) (OFC 1027.5)
24
Exit Signs
25
Electrical Hazards
26
Fire Alarm Systems
27
Fire Extinguishers
28
Fire/Smoke Separations
29
Fire Suppression Systems
30
Commercial Kitchen Hoods What wrong with this picture?
31
Heat Sources
32
Housekeeping/Decorations
33
Mechanical Hazards
34
Smoke Detection
35
Storage-Combustible
36
Storage-Compressed Gas Cylinders
37
Storage-Flammable Liquids
38
Storage-Hazardous
39
Questions?
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.