Presentation is loading. Please wait.

Presentation is loading. Please wait.

Scheme 1. Scheme of the quartz sample holder.

Similar presentations


Presentation on theme: "Scheme 1. Scheme of the quartz sample holder."— Presentation transcript:

1 Scheme 1. Scheme of the quartz sample holder.
From: DOSE RECONSTRUCTION FROM ESR SIGNAL OF GAMMA-IRRADIATED SODA-LIME GLASS FOR TRIAGE APPLICATION Radiat Prot Dosimetry. Published online January 11, doi: /rpd/ncy290 Radiat Prot Dosimetry | © The Author(s) Published by Oxford University Press. All rights reserved. For Permissions, please article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (

2 Figure 1. Variation of peak-to-peak amplitude of non-irradiated and samples after 2 and 20 Gy irradiation as a function of square root of the microwave power. From: DOSE RECONSTRUCTION FROM ESR SIGNAL OF GAMMA-IRRADIATED SODA-LIME GLASS FOR TRIAGE APPLICATION Radiat Prot Dosimetry. Published online January 11, doi: /rpd/ncy290 Radiat Prot Dosimetry | © The Author(s) Published by Oxford University Press. All rights reserved. For Permissions, please article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (

3 Figure 2. Variation of shapes of the spectra and intensities of (a) BKS and (b) total ESR signal at 10 Gy for six batches of soda-lime glass. Two satellite lines on the left and right side are third and fourth lines of the Mn<sup>2+</sup>/MgO internal standard. From: DOSE RECONSTRUCTION FROM ESR SIGNAL OF GAMMA-IRRADIATED SODA-LIME GLASS FOR TRIAGE APPLICATION Radiat Prot Dosimetry. Published online January 11, doi: /rpd/ncy290 Radiat Prot Dosimetry | © The Author(s) Published by Oxford University Press. All rights reserved. For Permissions, please article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (

4 Figure 3. Peak-to-peak amplitudes dependences of six samples from different batches (○, □,▼,◊,▲,●) on dose. From: DOSE RECONSTRUCTION FROM ESR SIGNAL OF GAMMA-IRRADIATED SODA-LIME GLASS FOR TRIAGE APPLICATION Radiat Prot Dosimetry. Published online January 11, doi: /rpd/ncy290 Radiat Prot Dosimetry | © The Author(s) Published by Oxford University Press. All rights reserved. For Permissions, please article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (

5 Figure 4. ESR spectra of irradiated (10 Gy) and non-irradiated (0 Gy) soda-lime glasses. The marks and abbreviations are explained in the text. From: DOSE RECONSTRUCTION FROM ESR SIGNAL OF GAMMA-IRRADIATED SODA-LIME GLASS FOR TRIAGE APPLICATION Radiat Prot Dosimetry. Published online January 11, doi: /rpd/ncy290 Radiat Prot Dosimetry | © The Author(s) Published by Oxford University Press. All rights reserved. For Permissions, please article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (

6 Figure 5. (a) Dependence of g<sub>eff</sub> on dose; experimental data and (b) curves obtained by equation (3), fitted parameters are shown in Table 1. From: DOSE RECONSTRUCTION FROM ESR SIGNAL OF GAMMA-IRRADIATED SODA-LIME GLASS FOR TRIAGE APPLICATION Radiat Prot Dosimetry. Published online January 11, doi: /rpd/ncy290 Radiat Prot Dosimetry | © The Author(s) Published by Oxford University Press. All rights reserved. For Permissions, please article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (


Download ppt "Scheme 1. Scheme of the quartz sample holder."

Similar presentations


Ads by Google