1 Comparison of other Sciamachy operational products
Envisat Validation Workshop Atmospheric Chemistry Validation Team Ground-Based Measurements and Campaign Database Subgroup Comparison of other Sciamachy operational products Renske Timmermans,

2 Contributions from AOID 427 – Yuri Timofeyev (PI), Dmitry Ionov
St. Petersburg State University AOID 126 – Martine de Maziere (PI), Thierry Coosemans BIRA-IASB AOID 174 – Hennie Kelder (PI), Renske Timmermans, Jan-Fokke Meirink, Ankie Piters KNMI Bogumil Kois Legionowo, Poland

3 Intercomparison of CO columns
Direct solar observations with IR spectrometer Intercomparison of CO columns CO columns The nearest SCIAMACHY pixel is selected within a 500 km range from the GB station Constant values found

4 CO columns

5 Intercomparison of CH4 columns
Direct solar observations with IR spectrometer Intercomparison of CH4 columns The nearest SCIAMACHY pixel is selected within a 500 km range from the GB station Constant values found

6 CH4 columns

7 CH4 columns BIAS_1_CH4 22 nov Constant value

8 Version 3.53, 25 October-10 November
H2O columns Version 3.53, 25 October-10 November BIAS-2 (ch ): all negative values version 4.0 positive values but orders of magnitude too high BIAS-1 (ch ): values between 0 en 3 x 10^5 kg m-2 1% of pixels is negative (not counting sza > 85 ) BIAS-0 (ch ): non-physical values, large spread with small given errors, many ‘normal’ values around 10 to 20 kg m-2. 0.1% of pixels is negative.

9 H2O columns

10 Intercomparison of H2O columns
Direct solar observations with IR spectrometer The nearest SCIAMACHY pixel is selected within a 500 km range from the GB station COMPARISON OF SCIAMACHY WITH GROUND-BASED MEASUREMENTS-AOID427

11 Intercomparison of H2O columns
 Sciamachy data * Integrated radiosonde * Closest Sciamachy pixel Mean difference : -33 % St. dev.: 35 %

12 Intercomparison of H2O columns
 Sciamachy data * Integrated radiosonde * Closest Sciamachy pixel Mean difference: 90 % St. dev.: 220 % * Integrated radiosonde/ozonesonde  Sciamachy data Sonde data from Bogumil Kois, IMWM, Legionowo, Poland

13 Intercomparison of H2O columns
Int. sonde on 29 oct = 15.4 kg/m2 Int. sonde on 5 nov = 10.0 kg/m2

14 Conclusions Sciamachy columns of CO, CH4 and H2O show non-physical values, orders of magnitude too high, negative values, large spread, constant values at high sza (close to gb values). Given the current status of these products, comparing with groundbased measurements does not give any additional information BrO, ClO, SO2, H2CO: not in the distributed products yet CO2, N2O: too unrealistic to do any comparisons (CO2 = 0, N2O orders of magnitude too large)