Quality Assured Measurements of Animal Building Emissions: Part 2. Particulate Matter Concentrations Albert Heber; Teng Lim; John Gallien, Ji-Qin Ni; Pei-Chun Tao Purdue University, West Lafayette, IN Larry Jacobson University of Minnesota, St. Paul, MN Jacek Koziel Texas A&M University, Amarillo, TX Steven Hoff Iowa State University, Ames, IA Yuanhui Zhang University of Illinois, Urbana, IL Jerry Baughman North Carolina State University, Raleigh, NC
2
Objectives Describe use of TEOM in livestock buildings to measure TSP, PM10 and PM2.5. Discuss QAQC Show some preliminary data collected this year
3
Laying House PM
6
Dust Measuring Strategies Determine temporal variation (Hinze et al., 1998) Semi-continuous mass monitor Representative exhaust fan (minimum winter) Calibrate with FRM Determine spatial variation (Wang et al., 1999) Multi-point gravimetric filter sampling Multiple exhausts plus ambient Calibrate with FRM
7
TEOM flow schematic
8
TEOM record in a pig house (Hinz et al., 1998)
9
PM Monitoring Schematic
10
Raceway Contains Vacuum Lines
11
TEOM PM 10
13
System Calibration Flow controller calibration (software) Mass flow controller calibration (hardware) Analog calibration Mass transducer verification Flow audit procedure Ambient temperature calibration Barometric pressure calibration
14
TEOM Maintenance Filter replacement PM-10 inlet cleaning Replacing large bypass in-line filter Replacing flow controller filters Cleaning air inlet system Leak testing
15
Changing TEOM Filter
16
Loaded TEOM Filter
17
Feathered Bug Screen
18
Plugged Bug Screen
19
PM10 Inlet Body
20
Large Particles Collected
21
Collocated TEOMS, FRM Fan inlet External screen PM 10 inlet Cabinet Wedding PM 10
22
Collocated PM10 Measurements 24-h at laying house exhaust Anticipatory Feeding
23
Four Collocated TEOMs in laying house exhaust (4/3/02)
24
TSP vs. PM 10 in Laying House Exhaust Air (5/2/02)
25
Collocated PM2.5, PM10, TSP at laying house
26
Effect of Filter Loading Humidity Effect
27
Lagoon Tunnel-ventilated finishing houses with flushing Oil sprinkled building
28
Oil Sprinkling
30
Oil pressure
32
TSP Measurements in Two Swine Barns (11/08/02)
33
Effect of Pig Activity on TSP
34
Nine shrouded vanes installed at laying house Open vane (cheaper) 50% variations with static pressure!
35
UIUC test of anemometer Calibration at UIUC BESS Lab
36
Open impeller vane anemometer
37
Open propeller
38
Small Vane Anemometer Readings vs. Building Static Pressure
39
Summary First measurements of TSP, PM10 and PM2.5 in livestock buildings in U.S. have been conducted. QAQC is critical to TEOM success. Moisture is adsorbed and desorbed Oil sprinkling reduces PM Real-time concentrations correlated to animal activity Anemometers provide real-time airflow data.
40
Check out www.AgAirQuality.com Questions?